§ 16-44.010 — Relationship of building to street
Atlanta City Code (Code of Ordinances, Part II) (Supp. No. 108, Update 1: codified through Ordinance No. 2026-37 (26-O-1511), enacted September 30, 2026) · Atlanta Land Development Code § 16-44.010
Corpus is an independent public-information project, not the official City of Atlanta website. Stable reference: corpuslaw.us/code/816512a9-81ca-4326-9fd9-9d3ae8b668fd
Sec. 16-44.010. - Relationship of building to street.
(1) Applicability. (a) This section 16-44.010 (Relationship of Building to Street) shall not apply properties zoned I-Mix, NC, MR, MRC, LW, or within the BeltLine Overlay due to similar existing requirements in those districts, except as otherwise provided in "b" immediately below. (b) Section 16-44.010(2) (Pedestrian Entrance) through section 16-44.010(5) (Residential uses) shall apply to properties zoned I-Mix, NC, MR, MRC, LW, or within the BeltLine Overlay when an existing building changes use or occupancy. (2) Pedestrian entrance. The primary pedestrian entrance for pedestrians to access all sidewalk level uses and business establishments facing a public street or required private street: (a) Shall be visible from the sidewalk adjacent to such street. (b) Shall be shall be linked to the required sidewalk with a pedestrian walkway a minimum of five-feet wide. See section 16-44.011(2)(d) for additional requirements for pedestrian walkways where retaining walls exist. (c) Shall remain unlocked during business hours for nonresidential uses. (3) Active sidewalk level uses required. (a) Buildings. Along public streets or required private streets, and as otherwise provided by this chapter: (i) Portions of buildings facing a required sidewalk shall provide a sidewalk level for the entire width of the building façade, except at ingress and egress points into parking structures or loading areas. The sidewalk level shall have a finished floor elevation within five vertical feet of the adjacent required sidewalk grade, measured on a point-by-point basis. (ii) Portions of building facades required by "i" immediately above shall only be used for active uses with a minimum depth of 20 feet for nonresidential uses and a minimum depth of ten feet for residential uses. (iii) Active uses required by "ii" immediately above shall mean any permitted use having interior floor area served by plumbing, heating, and electricity. Actives uses required by "ii" immediately above exclude parking; digital industry switchboards, relay equipment, and associated power generators; residential storage; non-residential storage not associated with an industrial use; and driveways or queuing lanes parallel to the adjacent street. (iv) When topography otherwise prevents this requirement from being satisfied with a single finished floor elevation, the finished floor elevation shall step so that it remains within five vertical feet of every portion of the adjacent required sidewalk grade. (b) Parking structures. See section 16-44.001(1) (Parking Structure Design Standards). (4) Fenestration. (a) Fenestration standards. Fenestration required by this. Section 16-44.010(4) shall: (i) Begin at a point not more than 36 inches above the sidewalk grade, to a height no less than ten feet above the sidewalk grade; or (ii) Begin at the finished floor elevation to a height no less than ten feet above the finished floor elevation when the finished floor elevation is three or more feet above the sidewalk grade; or (iii) Begin at a point not more than sidewalk grade, to a height no less than ten feet above the finished floor elevation when the finished floor elevation is below the sidewalk. (iv) Except for parking decks, fenestration shall not utilize painted glass, reflective glass or other similarly treated or opaque windows. (v) Glass on pedestrian doors/entrances count towards fenestration requirements, but glass on vehicular entrances/garages doors does not. (b) Industrial uses along all streets. Street-fronting industrial uses along public streets shall meet the following sidewalk level requirements: (i) Fenestration shall be provided for a minimum of 30 percent of the facade length. (ii) The façade length without fenestration or an entrance shall not exceed 75 feet. (c) Other non-residential uses along all streets. Street-fronting non-residential uses along public streets or required private streets, except for industrial uses, places of worship, and fire stations, shall meet the following ground floor requirements: (i) Fenestration shall be provided for a minimum of 65 percent of the facade length. (ii) The façade length without fenestration or an entrance shall not exceed 20 feet. (d)Residential uses along all streets. Street-fronting residential uses along public streets or required private streets shall meet the following ground floor requirements: (i) Fenestration shall be provided for a minimum of 30 percent of the facade length. (ii) The façade length without fenestration or an entrance shall not exceed 20 feet (e) Parking structures. See section 16-44.010(6) (Parking Structure Design Standards). (5) Residential uses. Buildings with ground floor residential uses shall meet the following: (a) All primary pedestrian entrances not adjacent to a required sidewalk shall be linked to the required sidewalk with a pedestrian walkway a minimum of five-feet wide. (b) All such buildings with more than four residential units that are adjacent to the required sidewalk shall have individual entrances to such units directly accessible from the sidewalk and shall open directly onto the adjacent sidewalk, park, plaza, terrace or porch adjacent to the sidewalk. All pedestrian walkways providing such access shall be perpendicular to the street and shall be permitted to share said walkway with one adjacent unit. See section 16-44.011(2)(d) for additional requirements for pedestrian walkways where retaining walls exist. (6) Parking structure design standards. Along public streets, parking structures: (a) Shall conform to the building active use standards of section 16-44.010(3)(a); and (b) Shall conform to the applicable fenestration standards of section 16-44.010(4) (Fenestration).
(Ord. No. 2023-13(22-O-1742), § 1(Att. A), 4-26-23)
Ask a question about Atlanta law
Corpus searches the Atlanta sections it holds and shows the ones that match, with their citations. Free, no sign-in.
