For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8-2182 — Barrier-free requirements

Atlanta City Code (Code of Ordinances, Part II) (Supp. No. 108, Update 1: codified through Ordinance No. 2026-37 (26-O-1511), enacted September 30, 2026) · Atlanta Land Development Code, art. F, § 8-2182

Corpus is an independent public-information project, not the official City of Atlanta website. Stable reference: corpuslaw.us/code/9f5e9c6f-4f84-480a-9b56-9e7ffe681e32

Sec. 8-2182. - Barrier-free requirements.

(a) Statement of Intent. The provisions of this section are specifically enacted to further the policy of the city to provide that new single-family, duplexes and triplexes which are constructed with public funds, as herein described, be provided with design features to provide accessibility and usability for physically disabled people. The purpose of this section is to specifically promulgate certain standards which may be less restrictive than ANSI A117.1 while economically providing solutions to accessibility. (b) Applicability. The following regulations shall be applicable to new single-family dwellings, duplexes, and triplexes which receive city assistance. For purposes of this section, "city assistance" shall mean funding or assistance from the city or any agency thereof, through any of the following means: (i) receipt of a building contract or similar contractual agreement involving any city-funded program or fund, including but not limited to the Urban Residential Finance Authority (URFA), the Housing Trust Fund, or similar programs; (ii) real estate purchased, leased or donated from the city or any agency thereof; (iii) receipt of preferential tax treatment, bond assistance, mortgage assistance, or similar financial advantages derived from the city or any agency thereof; (iv) dispersal under city auspices of any federal or state construction funds as CDBG; or (v) receipt of any other funding or financial benefit from the city or any agency thereof. (c) Design Requirements. The following design requirements shall apply: Requirement 1. Building entrances. Applicable dwelling units shall be designed and constructed to have at least one building entrance on an accessible route served by a ramp complying with ANSI A117.1-1986, section 4.8, having a maximum slope not to exceed twelve (1:12), unless it is impractical to do so because of terrain or unusual characteristics of the site. Such building entrance doors shall comply with ANSI A117.1, 4.13, and shall have a minimum clear opening of 32 inches. Any entrance at the front, side or back of the dwelling is acceptable as long as it is served by an accessible route such as a garage or sidewalk. Requirement 2. Interior door criteria. All dwelling units, whether or not on an accessible route, shall be designed in such a manner that all the doors designed to allow passage into and within all premises are sufficiently wide to allow passage by persons in wheelchairs. Lever hardware is required. Doors, except those serving closets less than 15 square feet in area, within individual dwelling units intended for user passage must provide minimum 32″ clear opening. A 2′-10″ door or standard 6′-0″ sliding patio door assembly is deemed sufficient to comply with this requirement; provided however, compliance with ANSI section 4.13.6 (Maneuvering Clearance at Doors) shall not be mandatory. Requirement 3. Accessible routes into and through the dwelling unit. An accessible route shall be designed and constructed in such a manner that a 36″ wide level route, except at doors, must be provided through the main floor of the unit with ramped or beveled changes at door thresholds. Requirement 4. Wall reinforcement in bathrooms. Reinforcement in the walls shall be provided at designated locations as specified by ANSI A 117.1, section 4.24, section 4.32, figure 48 and figure 49 so that grab bars may be installed, if needed, at a later date without the necessity of removing portions of the existing wall. Requirement 5. Light switches, electrical outlets, thermostats and other environmental controls. All applicable dwelling units shall be designed and constructed in such a manner that all premises contain light switches, electrical outlets, thermostats and other controls in accessible locations. Controls shall meet the requirements of ANSI A117.1, section 4.25. Where multiple controls serve the same elements (e.g., two remote switches for a light) only one need be accessible. (d) Contracts. The provisions of this section shall be incorporated in all city contracts. (e) Waiver of Exterior Disability Accessibility Regulations. The requirements of subsection (c), requirement 1 (Building Entrances) herein may be waived by the commissioner of housing, through the issuance of an "Exterior Disability Accessibility Waiver" ("waiver"). A person requesting said waiver shall file an application for disability accessibility waiver with the commissioner, including all documents necessary to prove the existence of the exemption standard herein. The application shall demonstrate that topographical conditions on the site render it impossible to comply with the provisions of subsection (c). If the application so demonstrates, the commissioner shall issue an exterior disability accessibility waiver to the applicant, in writing, within ten days of receipt of a completed application, which shall become an official component of any issued contract. The commissioner shall retain a copy of said waiver in the department's official records, and shall also forward a copy of said waiver to the director, bureau of buildings at the time of issuance.

(Code 1977, § 8-2182)

Ask a question about Atlanta law

Corpus searches the Atlanta sections it holds and shows the ones that match, with their citations. Free, no sign-in.