Sec. 3-3-25. - Special hazard buildings and structures.
(a) Certain buildings and structures may, because of construction or use, constitute a special hazard to property or to life and safety of persons on account of fire or panic caused by a fear of fire. Buildings constructed or used in the following manner present such a fire hazard: (1) Buildings or structures three (3) stories or more in height; however, nothing herein shall apply to any individually owned residential unit within any such building; (2) Any building three (3) or more stories in height and used as a residence by three (3) or more families, with individual cooking and bathroom facilities; provided, however, nothing herein shall apply to any individually owned residential unit within such building; (3) Any building in which there is more than fifteen (15) sleeping accommodations for hire, with or without meals but without individual cooking facilities, whether designated as a hotel, motel, inn, club, dormitory, rooming or boardinghouse, or by any other name; (4) Any building or group of buildings which contains schools and academies for any combination of grades 1 through 12 having more than fifteen (15) children or students in attendance at any given time and all state-funded kindergarten programs; (5) Hospitals, health care centers, mental health institutions, orphanages, nursing homes, convalescent homes, old-age homes, jails, prisons, and reformatories, and all administrative, public assembly, and academic buildings of colleges, universities, and vocational-technical schools. As used in this paragraph, nursing homes, convalescent homes and old-age homes shall mean any building used for the lodging, personal care, or nursing care on a twenty-four hour basis of four (4) or more invalids, convalescents or elderly persons who are not members of the same family; (6) Racetracks, stadiums and grandstands; (7) Theaters, auditoriums, restaurants, bars, lounges, nightclubs, dance halls, recreation halls, and other places of assembly having an occupant load of three-hundred (300) or more persons, except that the occupant load shall be one-hundred (100) or more persons in those buildings where alcoholic beverages are served. (8) Churches having an occupant load of five-hundred (500) or more persons in a common area or having an occupant load greater than one-thousand (1,000) persons based on total occupant load of the building or structure; (9) Department stores and retail mercantile establishments having a gross floor area of fifteen thousand (15,000) square feet on any one (1) floor or having three (3) or more floors that are open to the public. For purposes of this paragraph, shopping centers and malls shall be assessed upon the basis of the entire area covered by the same roof or sharing common walls; provided, however, that nothing contained herein shall apply to single-story malls or shopping centers subdivided into areas of less than fifteen thousand (15,000) square feet by a wall or walls with a two-hour fire resistance rating and where there are unobstructed exit doors in the front and rear of every such individual occupancy which open directly to the outside; (10) Group day-care homes and group day-care centers required to be licensed or commissioned as such by the Georgia Department of Human Resources and in which at least seven (7) children receive care. As used in this subparagraph, a group day care home means a day-care facility subject to licensure by the Georgia Department of Human Resources where at least seven (7), but not more than twelve (12), children receive care, and a group day care center means a day-care facility subject to licensure or issuance of a commission by the Georgia Department of Human Resources where more than twelve (12) children receive care. Fire safety standards adopted by rules of the Georgia Fire Safety Commissioner pursuant to O.C.G.A. § 25-2-4, which are applicable to group day-care homes and daycare centers, shall not require staff-to-child ratios; (11) Personal care homes required to be licensed as such by the Georgia Department of Human Resources and having at least seven (7) beds for nonfamily adults. The Georgia Fire Safety Commission shall, pursuant to O.C.G.A. § 25-2-4, by rule adopt state minimum fire safety standards for those homes, and any structure constructed as or converted to a personal care home on or after April 15, 1986, shall be deemed to be a proposed building pursuant to O.C.G.A. § 25-2-14(d) and that structure may be required to be furnished with a sprinkler system meeting the standards established by the Georgia Fire Safety Commissioner, if the chief of the fire department, or his/her duly authorized representative, deems this necessary for proper fire safety. (b) Any building or structure which is used exclusively for agricultural purposes, or which has been designated historic property or which is located within a designated historic district pursuant to the Georgia Historic Preservation Act approved April 8, 1980 (Ga. Laws 1980, p. 1723), as now or hereafter amended, shall be exempt from the classification of subsection (a) above. (c) Landmark museum buildings, whose designations are recognized by ordinances of Augusta-Richmond County, shall be governed by the provisions of O.C.G.A. § 25-2-13(b)(3) and the provisions of subparagraphs (B) and (C) of O.C.G.A. § 25-2-13(b)(3) are by reference incorporated herein as fully as if set forth verbatim herein. (d) Capacity as used in this section shall mean the maximum number of persons who may be reasonably expected to be present in any building or on any floor thereof at a given time according to the use which is made of such building. The bureau of fire prevention shall determine and by rule declare the formula for determining capacity for each of the uses herein. (e) Plans and specifications for all proposed buildings which come under classification in section 3-3-25 shall be submitted to and receive approval by the bureau of fire prevention before any state or Augusta-Richmond County building permit may be issued or construction started. All such plans and specifications submitted for review as required herein shall be accompanied by a one hundred-fifty dollar ($150.00) fee for buildings or structures less than or equal to ten thousand (10,000) square feet gross area. For buildings or structures more than ten thousand (10,000) square feet gross area, all such plans and specifications submitted for review shall be accompanied by a one hundred-fifty dollar ($150.00) fee and a fee of five cents ($0.05) per square foot for each square foot exceeding ten thousand (10,000) square feet gross area. All such plans and specifications submitted for review shall bear the seal and Georgia registration number of the drafting architect or engineer or otherwise have the approval of the bureau of fire prevention. A complete set of approval plans and specifications shall be maintained on the construction-site, and construction shall proceed in compliance with the minimum fire safety standards under which such plans and specifications were approved. The owner of any such building or structure, or his or her authorized representative, shall notify the bureau of fire prevention upon completion of approximately eighty (80) percent of the construction thereof and shall apply for a certificate of occupancy when construction of such building or structure is complete. (f) Every building or structure which comes under classification in section 3-3-25 shall have a certificate of occupancy issued by the bureau of fire prevention before such building or structure may be occupied. Such certificate of occupancy shall be issued for each class of occupancy within the building; shall carry a flat rate of one hundred-fifty dollars ($150.00); shall state the occupant load; shall be kept on file within each business establishment where issued or on file with the building owner; shall be posted in a prominent location within such business establish mentor building; and shall run for the life of the building except as provided in subsection (1) herein. (1) Every certificate of occupancy required in subsection (e) shall run for the life of the building, provided the internal or external features of the building are not materially altered, the type of occupancy remains unchanged, there has been no fire or serious consequences, or other hazard discovered which is not transferrable. (2) For purpose of this section, any existing building or structure listed in subsection (a) of this section shall be deemed to be a proposed building in the event such building or structure is subject to substantial renovation, a fire or other hazard of serious consequence, or a change in the classification of occupancy. For purposes of this section, substantial renovation shall mean any construction project involving exits or internal features of such building or structure costing more than the building's or structure's assessed value according to county tax records at the time of such renovation. (3) All federal, state, or local publicly-owned buildings covered by this section are exempt from any fee or license which may be herein specified. Such fees or licenses may be waived by the Augusta-Richmond County Commission where chargeable to churches and charitable organizations. (g) Assembly occupancies having occupant loads of one-hundred (100) or more shall be provided with a minimum of one trained crowd manager or crowd manager supervisor. Every crowd manager and crowd supervisor shall receive approved training in crowd management techniques. Where the occupant load exceeds two-hundred-fifty (250), additional trained crowd managers or crowd manager supervisors shall be provided at a ratio of 1:250, crowd manager/supervisor to occupants, respectively, unless otherwise permitted by the following: (1) This requirement shall not apply to assembly occupancies used exclusively for religious worship with an occupant load not exceeding two-thousand (2000) persons. (2) With the exception of assembly occupancies noted above where alcoholic beverages are consumed, the ratio of trained crowd managers to occupants shall be permitted to be reduced where, in the opinion of the Augusta-Richmond County fire chief, the existence of an approved supervised sprinkler system and the nature of the event warrant.
( Ord. No. 7107 , § 1, 2-3-2009)
Ask a question about Augusta-Richmond County consolidated government law
Corpus searches the Augusta-Richmond County consolidated government sections it holds and shows the ones that match, with their citations. Free, no sign-in.