For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 7-1-19.5 — Mothballing—Boarding specifications

Code of Ordinances of Augusta-Richmond County, Georgia (Recodification: codified through Ordinance No. 7807, adopted December 7, 2021) · Augusta Code of Ordinances § 7-1-19.5

Corpus is an independent public-information project, not the official City of Augusta-Richmond County consolidated government website. Stable reference: corpuslaw.us/code/ffa7c57d-193f-491c-9fe8-d5ca911845d5

Sec. 7-1-19.5. - Mothballing—Boarding specifications.

The property owner must comply with the following minimum requirements regarding windows, exterior doors and other openings in exterior walls of vacant structures. (1) Minimum cleaning and safety requirements. a. Remove to legal dumpsite all trash debris, garbage from inside, outside and under house before boarding. (Keep on file copy of all receipts from landfill or their disposal facility for review.) b. Correct health and structural hazards inside, outside and under house before boarding. (2) Minimum window board-up requirements. a. Remove windowpanes if broken. If window panes not broken, lower or raise window sash to permit installation of carriage bolts described below. b. Neatly cut a single piece of one-half (½) inch high grade exterior plywood that is sized to fit snugly inside the window opening against the windows stop. Consider installing two (2) inches x four (4) inches blocking within opening for back of plywood to rest against snugly. *Alternative materials (i.e: plexiglass) may be approved by the Code Enforcement Manager. c. Cut an opening centered and six (6) inches below the top of the plywood and install a metal soffit vent that covers the opening but allows light to enter the structure once the plywood has been installed. Use screws to attach the vent to the plywood. d. Cut at least two two (2) inches x four (4) inches wood support members that are sixteen (16) inches wider than the window opening. e. The support members are to be mounted horizontally and flush against the interior window casing with eight (8) inches extending left and right of the window opening. The top support should be located within one-fourth (¼) and one-third (⅓) of the window opening height from the top of the opening. The bottom support should be located within one-half (½) to one-third (⅓) of the window opening height from the bottom of the opening. f. Drill at least two holes in each of the two (2) inches x four (4) inches support members then drill holes in the plywood that line up with the holes drilled in the support members. g. Insert a washer over the end of a three-eighths (⅜) inch diameter round, smooth head, carriage bolt. h. Line up each hole in the two (2) inches x four (4) inches support member and the plywood. i. At each hole, insert a three-eighths (⅜) inch diameter carriage bolt from exterior to interior through the plywood, through the window opening and through the two (2) inches x four (4) inches and plywood toward each other until there is no play. j. Prime the exterior surface of the plywood. k. On the exterior, caulk the perimeter edges of the plywood. l. Paint the exterior surface of the plywood a flat color — i.e., dark grey or black. (3) Minimum exterior door board-up requirements. a. Remove door. b. Neatly cut a single piece of one-half (½) inch high grade exterior plywood that is sized to fit snugly inside the door opening against the doorstop. Consider installing two (2) inches x four (4) inches blocking within opening for back of plywood to rest against snugly. c. Cut an opening centered and six (6) inches below the top of the plywood and install a metal soffit vent that covers the opening but allow light to enter the structure once the plywood has been installed. Use screws to attach the vent to the plywood. d. Cut a least two two (2) inches times; four (4) inches wood support members that are sixteen (16) inches wider than the door opening. e. The support members are to be mounted horizontally and flush against the interior door casing with eight (8) inches extending left and right of the door opening. The top support should be located within one-fourth (¼) and one-third (⅓) of the door opening height from the top of the opening. The bottom support should be located within one-fourth (¼) to one-third (⅓) of the door opening height from the bottom of the opening. f. Drill at least two (2) holes in each of the two (2) inches x four (4) inches support member and the plywood. At each hole, insert a three-eighths (⅜) inch diameter carriage bolt from exterior to interior—through the plywood, through the door opening and through the two (2) inches x four (4) inches. g. Insert a washer over the end of a three-eighths (⅜) inch diameter round, smooth head, carriage. h. Line up each hole in the two (2) inches x four (4) inches support member and the plywood. At each hole, insert a three-eighths (⅜) inches diameter carriage bolt—from exterior to interior—through the door opening and through the two (2) inches x four (4) inches. i. Slip a three-eighths (⅜) inch diameter nut and washer over the end of the carriage bolt inside the structure and securely tighten the nut pulling the two (2) inches x four (4) inches and plywood toward each other until there is no play. j. Prime the exterior surface of the plywood. k. On the exterior, caulk the perimeter edges of the plywood. l. Paint the exterior surface of the plywood a flat color—i.e., dark grey or black. (4) Crawlspace/basement door, gable vent or other opening. a. Remove door or vent and install when necessary two (2) inches x four (4) inches blocking in the opening. b. Cut a single piece of one-half (½) inch high grade exterior plywood that will fit snugly against the outside edge of the blocking. c. Screw plywood snugly to blocking using at least one (1) inch screws. d. Prime the exterior surface of the plywood and caulk the perimeter edges. e. Paint the exterior surface of the plywood a flat color — i.e., dark grey or black.

( Ord. No. 6875 , § 1, 3-29-2006; Ord. No. 7327 , § 1(exh. A(7-1-19.5)), 2-21-2012; Ord. No. 7447 , § 1(exh. A(7-1-19.5)), 3-18-2014)

Ask a question about Augusta-Richmond County consolidated government law

Corpus searches the Augusta-Richmond County consolidated government sections it holds and shows the ones that match, with their citations. Free, no sign-in.