Within the Groundwater Recharge Area District, the following minimum standards shall apply: (a) Waste disposal facilities. All new waste disposal facilities must have synthetic liners and leachate collection systems. (b) Agricultural impoundments. New agricultural impoundments shall meet the following requirements: (i) For areas of high susceptibility, a liner shall be provided that is approved by the U. S. Soil Conservation Service (SCS). (ii) For areas of medium susceptibility, an SCS-approved liner shall be provided if the site exceeds 15 acre feet. (c) Land disposal. No land disposal of hazardous waste shall be permitted within any Significant Groundwater Recharge Area. (d) Spill and leak protection. For all Significant Groundwater Recharge Areas, the handling, storage and disposal of hazardous materials shall take place on an impermeable surface having spill and leak protection approved by the Georgia Department of Natural Resources, Environmental Protection Division (EPD). (e) Secondary containment. For all Significant Groundwater Recharge Areas, new above-ground chemical or petroleum storage tanks larger than 660 gallons must have secondary containment for 110 percent of tank volume or 110 percent of the largest tanks in a cluster of tanks. (f) Wastewater basins. For High Pollution Susceptibility Areas, new waster-water treatment basins shall be an impermeable liner approved by EPD. (g) Stormwater basins. For High Pollution Susceptibility Areas, no new stormwater infiltration basins may be constructed. (h) Wastewater spray and sludge operation. For High Pollution Susceptibility Areas, wastewater spray irrigation systems or the land spreading of wastewater sludge shall be practiced in accordance with Department of Natural Resources criteria for slow rate land treatment. An application for a development permit for activities involving wastewater spray irrigation or land spreading of wastewater sludge must be accompanied by proof that the applicant has received a Land Application System permit from EPD. (i) Minimum lot sizes and septic systems. New homes served by septic tank/drain systems shall conform to minimum lot size requirements identified in Tables 1-3 below. (Note: No construction may proceed on a building permit or mobile home to be served by a septic tank without approval of the proposed septic system by the Richmond County Health Department). The following shall be exempted from all provisions of this Ordinance related to lot size: (a) Lots which are included on an "Overall Concept Plan" per Section 104.3 of the Subdivision Regulations, or a "Sketch Plan" per Section 200.1 of the Subdivision Regulations and submitted prior to 5:00 p.m. on the date of adoption of this Ordinance; and (b) Lots which are included on a "Development Plan" per Article III of the Subdivision Regulations and submitted prior to 5:00 p.m. on December 31, 1998; and (c) "Lots of record" (as defined herein) prior to 5:00 p.m. on December 31, 1998. _____ TABLE 1: Minimum Lot Size Requirements. Source: DHR Manual for On-Site Sewerage Management Systems. Pollution Susceptibility | New Homes Served by Septic Systems | New Mobile Homes Served by Septic Systems High | 150% of minimum lot sizes specified in Table 2 | 150% of minimum lot sizes specified in Table 3 Medium | 125% of minimum lot sizes specified in Table 2 | 125% of minimum lot sizes specified in Table 3 Low | 110% of minimum lot sizes specified in Table 2 | 110% of minimum lot sizes specified in Table 3 TABLE 2. Single Family Home Minimum Lot Size where served by On-Site Septic Tank Systems. Source: DHR Manual for On-Site Sewerage Management Systems. SOIL GROUP (SEE APPENDIX) SLOPE OF LOT (%) | 1 | 2 | 3 | 4 | 5 MINIMUM LOT SIZE SQUARE FEET 0-5 | 30000 | 390000 | 48000 | 51000 | 60000 5-15 | 33000 | 42000 | 51000 | 54000 | 66000 15-25 | 36000 | 45000 | 54000 | 57000 | N/A 25-35 | 39000 | 48000 | 57000 | 60000 | N/A TABLE 3. Mobile Home Parks Lot Size where served by On-Site Septic Tank Systems. Source: DHR Manual for On-Site Sewerage Management Systems. SOIL GROUP (SEE APPENDIX) SLOPE OF LOT (%) | 1 | 2 | 3 | 4 | 5 MINIMUM LOT SIZE SQUARE FEET 0-5 | 10000 | 13000 | 16000 | 17000 | 20000 5-15 | 11000 | 14000 | 17000 | 18000 | 22000 15-25 | 15000 | 18000 | 18000 | 19000 | N/A 25-35 | 13000 | 16000 | 19000 | 20000 | N/A _____
( Ord. No. 7280 , § 1(8-6-11), 9-6-2011)
Ask a question about Augusta-Richmond County consolidated government law
Corpus searches the Augusta-Richmond County consolidated government sections it holds and shows the ones that match, with their citations. Free, no sign-in.