For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 10B-53 — Minimum protection criteria for groundwater recharge areas

Code of Columbus, Georgia (Supp. No. 77, Update 1: codified through Ordinance No. 26-047, adopted September 22, 2026) · Columbus, Ga., Code § 10B-53

Corpus is an independent public-information project, not the official City of Columbus website. Stable reference: corpuslaw.us/code/6907bc23-5e9e-430e-9a7b-57c048101cd2

Sec. 10B-53. - Minimum protection criteria for groundwater recharge areas.

(a) New aboveground chemical or petroleum storage tanks, having a minimum volume of 660 gallons, shall have secondary containment for 110 percent of the volume of such tanks or 110 percent of the volume of the largest tank in a cluster of tanks. Such tanks used for agricultural purposes are exempt, provided they comply with all federal requirements. (b) New agricultural waste impoundment sites shall be lined if they are within a medium pollution susceptibility area and exceed 15 acre-feet in size and if they are within a low pollution susceptibility area and exceed 50 acre-feet in size. As a minimum, the liner shall be constructed of compacted clay having a thickness of one-foot and a vertical hydraulic conductivity of less than 5 * 10 7 cm/sec or other criteria established by the U.S. Soil Conservation Service. (c) New homes served by septic tanks/drain field systems shall be on lots having the following minimum size limitations as identified on Table MT-1 of the Department of Human Resources "Manual For On-Site Sewage Management Systems." (DHR Table MT-1) (1) 125 percent of the subdivision minimum lot size of DHR Table MT-1 if they are within a medium pollution susceptibility area. (DRASTIC Rating of 141 to 181) (2) 110 percent of the subdivision minimum lot size of DHR Table MT-1 if they are within a low pollution susceptibility area. (DRASTIC Rating of less than 141) (d) New mobile home parks served by septic tank/drain field systems shall have lots or spaces having the following size limitations as identified on Table MT-2 of the Department of Human Resources "Manual For On-Site Sewage Management Systems." (DHR Table MT-2) (1) 125 percent of the subdivision minimum lot or space size of DHR Table MT-2 if they are within a medium pollution susceptibility area. (DRASTIC Rating of 141 to 181) (2) 110 percent of the subdivision minimum lot or space size of DHR Table MT-2 if they are within a low pollution susceptibility area. (DRASTIC Rating of less than 141) (e) The Columbus Consolidated Government may exempt existing lots of record from the minimum lot size requirements of subsection (c) for homes and subsection (d) for mobile homes. (f) If the Columbus Zoning Ordinance requires a larger lot size than that required by subsection (c) for homes or subsection (d) for mobile homes, the larger lot size shall be used. (g) No construction may proceed on a building or mobile home to be served by a septic tank unless the Columbus Health Department first approves the proposed septic tank installation as meeting the standards of the DHR manual and minimum lot size requirements. (h) New facilities which handle hazardous materials of the types listed in Section 312 of the Resource Conservation and Recovery Act of 1976 (excluding underground storage tanks) and in amounts of 10,000 pounds or more on any one day shall perform their operations on impervious surfaces and in conformance with any applicable federal spill prevention requirements and any local fire prevention code requirements. (i) The Columbus Consolidated Government having jurisdictional authority over all significant recharge areas within its boundaries shall adopt, implement, and enforce said ordinance meeting the minimum groundwater protection standards developed by the Georgia Department of Natural Resources and adopted as required environmental criteria by the Georgia Department of Community Affairs.

(Ord. No. 00-19, § C, 2-15-00)

Ask a question about Columbus law

Corpus searches the Columbus sections it holds and shows the ones that match, with their citations. Free, no sign-in.