For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 2.5.12 — Planned Unit Development (PUD)

Code of Columbus, Georgia (Supp. No. 77, Update 1: codified through Ordinance No. 26-047, adopted September 22, 2026) · Columbus, Ga., Code § 2.5.12

Corpus is an independent public-information project, not the official City of Columbus website. Stable reference: corpuslaw.us/code/52486aea-f4f0-4b90-a2dd-a78372b2f7bf

Section 2.5.12. - Planned Unit Development (PUD).

A. Purpose and Intent. The purpose and intent of the PUD overlay zoning district is to: 1. Provide residential development that is consistent with the comprehensive plan; 2. Provide residential development that is compatible with and enhances surrounding land use patterns; 3. Allow a departure from strict adherence to property development, use and similar requirements applicable to a standard zoning district; 4. Provide residential development that allows for creative and innovative design; 5. Provide residential development that provides a variety of circulation patterns; 6. Provide residential development that supports and encourages the use of cluster development techniques; 7. Provide buffering and landscaping in excess of current requirements; 8. Encourage infill residential development; 9. Provide residential development in a manner that conserves natural and environment resources; 10. Provide residential development that creates large areas of open spaces for common use and enjoyment; 11. Provide for community-serving commercial development; and 12. Encourage voluntary dedication of land or other benefits to the public and City. B. Required Rezoning. 1. Rezoning Required. Any residential development that exceeds either the minimum site size or number of dwelling units as indicated in Table 2.5.2 shall be considered a PUD and shall be required to be rezoned to a PUD overlay zoning district. 2. Reserved. C. Permitted Housing Types. All types of residential dwellings, excluding mobile homes, may be permitted within a PUD. D. Commercial Centers. As part of a PUD approval, the Council may approve a neighborhood commercial center or a community commercial center, subject to the criteria and standards provided in this Section. A neighborhood or community commercial center within a PUD may be allowed, subject to the standards listed below. 1. Neighborhood Commercial Centers. (A) Purpose and Intent. The purpose and intent of neighborhood commercial centers within a PUD is to provide neighborhood commercial, retail and personal services to the residents, without the necessity of traveling outside the boundaries of the community. (B) Limit. Not more than ten percent of the gross land area of a PUD may be developed for neighborhood-serving commercial or office uses. This area may be increased, to a maximum of an additional ten percent, on the basis of one percent for each acre dedicated without charge for a public purpose such as a right-of-way, public school or park. (C) Permitted Uses. Uses in neighborhood commercial center shall be same as the permitted or special exception uses in the NC zoning district, as may be modified by a planned development approval. (D) Locational Standards. Neighborhood commercial centers shall be constructed in one or more locations that optimize availability to PUD residents. Neighborhood commercial centers shall be designated on the PUD master plan. The location of a commercial center is subject to the overall standards listed below. (1) PUD-Serving. The size, intensity, and proposed uses within the proposed neighborhood commercial center are appropriate as PUD-serving uses, and are not of a nature requiring a larger market area. (2) Civic Uses. The proposed neighborhood commercial center may contain civic uses of a PUD-serving nature, including postal services, meeting facilities, recreation facilities, and administrative offices. (3) Access. The neighborhood commercial center will not be accessible from any public or private roads abutting the PUD. (4) Central Area. The proposed neighborhood commercial center will be generally located at the center of a project. If multiple neighborhood centers are provided, the location shall be central to a phase or identifiable portion of the PUD. (5) Visibility. The proposed neighborhood commercial center will not be visible from any public roads abutting the PUD. (6) Intersection Location. The proposed neighborhood commercial center will be located at the intersection of two or more neighborhood collector or neighborhood-serving roads. (7) Advertising. The proposed neighborhood commercial development site will not be advertised in any fashion on abutting public roads. (E) Waivers. Waivers to PUD standards may be granted as provided in Section 2.5.18. 2. Community Commercial Centers. (A) Purpose and Intent. The purpose and intent of community commercial centers approved in association with a PUD is to provide commercial, retail and personal services to the residents, without the necessity of traveling outside the boundaries of the community. (B) Maximum Size Limit. (1) Maximum Land Area. The lesser of 15 acres or ten percent of the gross land area of a PUD may be developed for community-serving commercial or office uses, subject to the limitations listed below. (a) This area may be increased, to a maximum of an additional ten percent, on the basis of one percent for each acre dedicated without charge for a public purpose such as a right-of-way, public school or park. (b) The gross land area of the residential portion of the PUD must be at least five times as large as the gross land area of the PUD that is used for community commercial purposes. (2) Maximum Number of Square Feet. A community-serving shopping center shall not exceed 150,000 square feet, unless a specific waiver to exceed that limit is approved by the Council as provided in Section 2.5.18. (C) Permitted and Special Exception Uses. (1) Permitted Uses. Uses in community commercial center shall be same as the permitted or special exception uses in the NC zoning district, as may be modified by the Council as part of a PUD approval. (2) Mix of Users. A mix of retail, office and personal services shall be located within a community commercial center. Each center shall provide at least three separate users or tenants. (3) Prohibited Uses. Regional, "big box," and similar types of uses that attract clientele from within and outside the community are prohibited. (4) Maximum Size of Permitted Uses. Individual uses shall not exceed a maximum of 5,000 gross square feet. This limit may be waived by the Council, for specific community-serving uses such as grocery stores, drug stores and similar types of uses providing goods and services of a daily or routine nature. (D) Locational Standards. Community commercial centers shall be constructed with principal frontage along either arterial or collector roads. (E) Compatibility. Community commercial centers shall be designed, constructed and operated to minimize impacts on all surrounding properties, including all street frontages. Factors to be addressed during the development review process include, but are not limited to the following: (1) Buffering; (2) Landscaping; (3) Lighting; (4) Hours of operation; (5) Location of garbage, refuse, recycling and similar collection facilities; (6) Architectural features; (7) Stormwater and drainage; and (8) Types of uses that are community-serving. (F) Conceptual Master Plan Designation. PUD community commercial centers shall be designated on the PUD conceptual master plan. (G) Civic Uses. The proposed commercial center may contain civic uses of a community-serving nature, including postal services, meeting facilities, recreation facilities, and administrative offices. (H) Waivers. Waivers to PUD standards may be granted as provided in Section 2.5.18.

(Ord. No. 14-19, § 2, 5-27-14)

Ask a question about Columbus law

Corpus searches the Columbus sections it holds and shows the ones that match, with their citations. Free, no sign-in.