§ 50-34 — Fire protection
Code of Ordinances of the City of Kennesaw, Georgia (Codified through Ordinance No. 2026-06, enacted March 2, 2026. (Supp. No. 37)) · Kennesaw Municipal Code § 50-34
Corpus is an independent public-information project, not the official City of Kennesaw website. Stable reference: corpuslaw.us/code/0659f5cf-d4ef-465b-bc7c-884be0104fde
Sec. 50-34. - Fire protection.
(a) Access to mobile homes for firefighting. Approaches to all mobile homes shall be kept clear for firefighting. Conductors of overhead wiring systems shall have a clearance of not less than 18 feet above park roadways. (b) Fire alarms. Provision shall be made for giving an alarm in case of fire. (c) Fire alarm reporting; commercial telephone facilities. Private telephones shall be used to report and give the alarm of fire. A specific telephone number 422-2121 has been assigned for fire alarm emergency service. A telephone decal with the fire department number will be supplied by the county bureau of fire prevention to the park owner/operator. Sufficient quantities of the decals will be available to ensure that each private telephone within the park has the fire department number displayed. The park owner/operator will be responsible for supervising this program. (d) Tenant instruction. It shall be the responsibility of the mobile home park operator to inform all tenants about means for summoning fire apparatus, police departments, and park employees. (e) Public fire protection. Water supply facilities for fire department operations shall be provided, to consist of one or more of the following, so arranged as to permit the operation of a minimum of 2½-inch hose streams on any fire in a mobile home or elsewhere in the mobile home park. Water supply and associated facilities shall be sufficient to provide a delivery of at least 75 gallons per minute at each of two nozzles, held four feet above the ground, at a flowing pressure of at least 30 pounds per square inch at the highest point in the court. The utilization of available firefighting equipment may be assumed in determining compliance with these minimums: (1) A public water supply system with hydrants located within 500 feet of all mobile home parking sites. (2) A private hydrant system complying with NFPA standard 24, Outside Protection, except that where fire department services are available, no supply of hose shall be required, and hydrants so located that one will be within 500 feet of all mobile home parking sites shall be sufficient. (3) An approved private system with hydrants connected to domestic water supply, so arranged as to provide protection equivalent to subsections 705(a) and (b). No standards are available on such a system as it will have to be designed and approved for the individual mobile home park. (4) An approved suction supply or supplies each of not less than 3,000 gallons suitable for fire department pumper drafting, and so located that each mobile home site will be within 500 feet of a supply point. (5) When fire departments are equipped with tank trucks for water supply, in accordance with NFPA standard 19, Specifications for Motor Fire Apparatus, and such trucks are so located that, in case of fire, they can respond as soon as firefighting personnel, they may be accepted in lieu of a fixed water supply by permission of the fire marshal. (f) Private fire protection. Where no fire department is available, arrangement shall be made for private firefighting facilities adequate for the individual mobile home park, as determined by the fire marshal. (g) Portable fire appliances. Approved facilities shall be provided for fighting fires in ordinary combustible materials (class A), readily accessible to all mobile home occupants, in readily visible locations. Such facilities may consist of class A extinguishers (soda-acid, pump tank, antifreeze), in accordance with NFPA standard 10, Installation, Maintenance and Use of Portable Fire Extinguishers, so located that it will not be necessary to travel more than 100 feet from any mobile home to reach the nearest extinguisher, or may consist of garden hose of a type usable in all weather, permanently attached or in cabinets immediately adjacent to the hose connection, so located that any part of any mobile home can be reached with a garden hose stream. (h) Extinguisher spacing. One or more approved extinguishers of a type suitable for flammable liquid or electrical fires (class B and class C), in accordance with NFPA standard 10, Portable Fire Extinguishers (carbon dioxide or dry chemical), shall be so located that it will not be necessary to travel more than 100 feet to reach the nearest extinguisher. (i) Care of fire appliances. Appropriate arrangements shall be made to prevent freezing of firefighting equipment in any area subject to freezing.
(Code 1986, § 4-2-6(i))
Ask a question about Kennesaw law
Corpus searches the Kennesaw sections it holds and shows the ones that match, with their citations. Free, no sign-in.