For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 6.05.12 — Non-Residential Driveways

Code of Ordinances of the City of Kennesaw, Georgia (Codified through Ordinance No. 2026-06, enacted March 2, 2026. (Supp. No. 37)) · Kennesaw Municipal Code, App. A, ch. 6, § 6.05.12

Corpus is an independent public-information project, not the official City of Kennesaw website. Stable reference: corpuslaw.us/code/e23e3529-7ed8-4b28-a518-61b2997b3383

6.05.12 - Non-Residential Driveways

Driveways servicing developments shall provide uninterrupted ingress/egress to and from the site. The minimum distance required is measured from the street right-of-way line at the ingress/egress to the outer edge of any interior service drive or parking space with direct access to such driveway as measured perpendicularly from the street. The length of the uninterrupted ingress/egress is determined by the maximum peak hour volume of the facility in which the driveway is provided and as shown in the table below. The developer shall provide this information. MAXIMUM PEAK HOUR VOLUME | UNINTERRUPTED INGRESS/EGRESS UP TO 50 VEHICLES | 25' 50 TO 150 VEHICLES | 50' 150 TO 500 | 100' 500 and Up | 150' Non-residential driveways shall not be designed or marked to allow more than one lane of traffic to exit onto a street simultaneously, unless such driveway is channelized in accordance with traffic engineering design principles as applicable when designing channelized street intersections. As may be requested, left-turn driveway lanes shall be a minimum of 12 feet wide and provide a minimum 150 feet storage with 100 feet transition. Non-Residential driveways are to be constructed to the following standards: 1. Width - Minimum 24' two way access *Maximum 32' two way access Minimum 14' one-way access Maximum 18' one-way access 2. Radii - Minimum 30' Maximum 50' 3. Spacing from street intersection - Minimum one hundred (100) feet tangent 4. Composition - Shall meet or exceed the same specification as the connecting public roadway 5. Drainage - Consistent with existing drainage plan of the connecting public roadway unless other improvements are required for safety, hydrological and environmental considerations 6. Angle of intersection with roadway - Approximately right angled 80 o to 100 o 7. Corner/intersection sight distance - To comply with corner/intersection sight distance requirements of roadway intersected with the driveway as per these regulations 8. Landing grade - +2 percent of intersecting roadway within the right-of-way Driveway designs other than as provided within these regulations, i.e., median divided or additional lanes, are subject to consideration of the CDOT, GDOT, or Public Works Department.

Ask a question about Kennesaw law

Corpus searches the Kennesaw sections it holds and shows the ones that match, with their citations. Free, no sign-in.