Section 29.05. - Final plat specifications.
[1] Conformance with the preliminary plat. The final plat shall conform to the conditions of approved preliminary plat. [2] Original tracing specifications. Final plats shall be a good legible copy, such as a blue, white, or other commercial print reproduced from an original and shall comply with all requirements of the "Georgia Plat Act," Section [1](a). The scale shall be a minimum of one hundred (100) feet to the inch on a sheet size of not less than eight and one-half (8½) inches by eleven (11) inches nor greater than seventeen (17) inches by twenty-two (22) inches. If the complete plat cannot be shown on one (1) sheet of this size, it may be shown on more than one (1) sheet with an index map at a reduced scale. [3] Additional specifications. The final plat shall contain the following information: (a) North point, graphic scale, and date; (b) Tax map designation; (c) Names of owners of record of adjoining land; (d) Location of streams, lakes, swamps and land within the elevation of the regulatory flood as required; (e) Tract boundary lines, municipal or county lines when included within the subdivision, right-of-way lines, lines of street easements, property lines of residential lots and other sites with sufficient data to determine readily and to reproduce on the ground the location, bearing, and length of every street line, lot line, boundary line, whether curved or straight. This shall include, but not be limited to, the length of arc; internal angles and bearings of the tangent distances for the center line of curved streets and curved property lines that are not the boundary of curved streets. All dimensions shall be given to the nearest one-hundredth ( 1/100 ) of a foot and all angles shall be given to the nearest minute; (f) Exact boundary lines of the tract, determined by a field survey, giving distances to the nearest one-hundredth ( 1/100 ) of a foot and angles to the nearest minute, shall be balanced and closed with an apparent error of closure not greater than one foot (1FT) in ten thousand feet (10,000FT); (g) Widths and names of all streets and alleys within the new subdivision shall be shown on the plat; (h) Land-lot and land-district number(s) shall be shown; (i) Lots shall be numbered in numerical order and blocks lettered alphabetically or section labeled appropriately; (j) Each parcel platted shall have a street address which has been assigned by the County Engineer's Office. Parcels shall include but are not limited to drainage lots, cemeteries, detention ponds, green space, common areas, parks and building lots. Parcels not intended for use as building lots shall be labeled as such and listed in a note on the plat that includes the address, acreage, and proposed use(s). (k) Location, dimensions, and purposes of any easements and any areas to be reserved or dedicated for the public use shall be shown on the plat; (l) Accurate location, material, and description of monuments and markers shall be described on the plat; (m) Minimum building front yard setback lines shall be shown; (n) Point of Reference to nearest street right-of-way intersection, indicated by a directional arrow and distance; (o) All buildings on the property shall be shown. In the case of large tracts subdivided, the surveyor shall include a certification that no building(s) located on the property encroaches the required setback from the new property line(s) as shown; (p) A statement shall be shown on the plat as follows: "Due diligence has been performed by this surveyor regarding easements and research has been conducted regarding easements for utilities and ingress/egress. All easements apparent on the ground and/or those for which recorded documents were found are shown hereon." [4] Final plat approval of single-family attached. The Executive Director or his designee will require that all provisions of the preliminary plat and subsequent Commission approval be obtained. All final plats shall conform to Section 29.05[1] through [3] and shall reflect "As-Built Conditions." [5] A surveyor's certification. A signed certification by a registered land surveyor certifying to the accuracy of the survey and the plat shall be placed on the final plat as follows: "The field data upon which this map or plat is based has a closure precision of one foot in _____ feet and an angular error of _____ per angle point, and was adjusted using the _______ rule. This map or plat has been calculated for closure and is found to be accurate within one (1) foot in _____ feet. The linear and angular measurements shown on this plat were obtained by using a _______ and _______. By: _____ Georgia Registered Land Surveyor Number" [6] An owner's certification. A signed certification of ownership shall be placed on the final plat as follows: "Owner's Certification: State of Georgia, County of Bibb The undersigned certifies that he is the owner of the land shown on this plat and acknowledges this plat and allotment to be his free act and deed and dedicates to public use forever all areas shown or indicated on this plat as streets, alleys, easements, or parks. I also understand that said dedication does not imply acceptance by the applicable governing body for maintenance of any streets, alleys, easements or parks, and that appropriate petitions must be made to and approved by the applicable governing body for public maintenance. _____ | _____ Date | Owner's Signature" [7] Fire Department certification. A signed certification of the Fire Department shall be placed on the final plat as follows: (a) "Approved by Macon-Bibb County Fire Department _____ | _____ Date | Fire Official" (b) "Approval subject to installation of proper water mains and fire hydrants Macon-Bibb County Fire Department _____ | _____ Date | Fire Official" (c) "Approved—Limited water supply—No fire hydrants within 500 feet—in County only. _____ | _____ Date | Fire Official" [8] Health Department certification. A signed certification of the Macon-Bibb County Health Department shall be placed on the final plat as follows: (a) "Approval of this plat by the Department of Health is solely for the purpose of permitting it to be recorded in the Bibb County Superior Court. Said approval does not imply nor is it intended to grant permission to any person to construct any building or to install a sewage disposal system or water supply system on property covered by this plat. Approved for Recording Purposes Only Macon-Bibb County Health Department _____ | _____ Date | Macon-Bibb Co. Health Department Designee (b) Health Department approval relates to general subdivision lot layout only. Individual approval required for each lot prior to construction. (c) Restricted to public sewers and public water supply. (d) Approved by Macon-Bibb County Department of Health _____ | _____ Date | Macon-Bibb Co. Health Department Designee" The blanks on the certification statement of Macon-Bibb County Health Department shall be completed by the director of environmental health, or his designee, so as to indicate whether approval is based upon the use of individual sewerage systems, individual water supplies, a community sewerage system, a community water supply or a combination thereof. [9] A certificate of approval by the County Engineer. A signed certification of the County Engineer for plats of property located in unincorporated Bibb County shall be placed on the final plat as follows: "I certify that the final plat layout meets the platting requirements of the County of Bibb Engineering Department. The County of Bibb does not, by this approval, accept the dedication, if any, of drainage easements and assumes no responsibility for their maintenance. _____ | _____ Date | County Engineer or Designee" [10] A certificate of approval by the City Engineer. A signed certification of the City Engineer shall be placed on the final plat for properties within the city limits of Macon as follows: "I certify that the final plat layout meets the platting requirements of the City of Macon Engineering Department. The City of Macon does not, by this approval, accept the dedication of drainage easements or any other public improvement dedicated by this plat." _____ | _____ City Engineer or Designee | Date" [11] Water and sewerage certification. A signed certification of Macon Water Authority shall be placed on the final plat as follows: "I certify that the specifications of the water and/or sewer lines meet the minimum requirements of the Macon Water Authority and that the installation meets with such specifications and proper financial arrangements have been made to insure installation according to said specifications; therefore, the final plat is approved by the Authority. _____ | _____ Date | Executive Director, Engineering Superintendent or Designee" A note as follows shall be placed on all subdivision plats: "IMPORTANT NOTICE TO POTENTIAL LOT PURCHASERS/DEVELOPERS: The following fees apply to each lot in this subdivision and must be paid to the Macon Water Authority at the time each lot is developed: Basin Specific Fee _______ Meter Fee _______ Sewer Tap Fee: _______ The above fees are subject to change at ay time by action of the Macon Water Authority." The developer/subdivider must contact the Macon Water Authority Engineering Department for the specific amounts to be inserted into the blanks. [12] Traffic Engineering Department certification. A signed certification of approval from the Macon-Bibb County Traffic Engineering Department shall be placed on the final plat as follows: "Approved by the Macon-Bibb County Traffic Engineering Department. _____ | _____ Date | Macon-Bibb County Traffic Engineer or Designee" [13] Certification of final approval by the Commission. Certification of final approval by the Executive Director or his designee shall be placed on the final plat only after every item in Section 29.05 has been complied with and shall state the following: "I certify that all the requirements for Final Approval of this Plat have been fulfilled in accordance with the Resolutions of Macon-Bibb County Planning and Zoning Commission. _____ | _____ Date | Executive Director or his designee"
(Amended November 10, 2008, ZA08-11-01)
Ask a question about Macon-Bibb County law
Corpus searches the Macon-Bibb County sections it holds and shows the ones that match, with their citations. Free, no sign-in.