6-20-060 - Definitions.

For the purpose of this chapter, the following words shall have the meanings respectively ascribed to them: A. Cross Connection. A physical connection between two otherwise separate piping systems or vessels one of which contains potable water and the other does not. B. Cross Connections, Non-pressure Type. A low inlet installation where a potable water supply pipe is connected or extended below the overflow rim of a receptacle, or an environment, that does not contain potable water and which is at atmospheric pressure. C. Cross Connection, Pressure Type. An installation where a potable water supply pipe is connected to a closed vessel, or a piping system, that does not contain potable water and which is above atmospheric pressure. D. Containment. Installation of an appropriate device at the service connection to prevent backflow or back-siphonage. E. Isolation. Installation of an appropriate device at the source of a cross connection on a premises to prevent backflow or backsiphonage. F. Backflow preventer. A device or means to prevent backflow or backsiphonage. G. Reduced Pressure Backflow Prevention Device. A reduced pressure principal backflow prevention device is a device that consists of two springloaded independently acting check valves with an intermediate, or reduced pressure zone draining to the atmosphere by an independently acting relief valve. H. Vacuum Breaker. A general term applied to a backsiphonage prevention device that introduces air into the potable water system. I. Vacuum Breaker, Atmospheric Type. A vacuum breaker designed for use under flow conditions only, not to exceed twenty-four (24) consecutive hours, and where it will be subject to no static pressure, and no back pressure. J. Vacuum Breaker, Hose Type. A vacuum breaker designed for hose connection only. It is not approved for continuous pressure, static or flowing. K. Double Check Valve Assembly. An assembly of at least two independently acting check valves. L. Air Gap. An unobstructed vertical distance between the lowest opening from any pipe or facet [sic] supplying water to a tank, plumbing fixture or other device and the flood level rim of the receptacle. M. Contaminate. A toxic substance that if introduced into the potable water supply would create a health hazard. N. Pollutant. A non-toxic substance that if introduced into the potable water supply would be objectionable but would not create a health hazard.

(Code 1978, § 5-5006; Ord. No. 5575, 6/12/96)

Ask a question about Marietta law

Corpus searches the Marietta sections it holds and shows the ones that match, with their citations. Free, no sign-in.