For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 6-8-3-020 — Maximum flow and water consumption requirements

Municipal Code of the City of Marietta, Georgia (Codified through Ordinance No. 8523, enacted June 10, 2026. (Supp. No. 56)) · Marietta Municipal Code § 6-8-3-020

Corpus is an independent public-information project, not the official City of Marietta website. Stable reference: corpuslaw.us/code/0edfceb6-f974-48bf-a5a0-3c9ebcf711e4

6-8-3-020 - Maximum flow and water consumption requirements.

A. Consistent with the general approach taken in Georgia, these maximum flow and water consumption requirements and related definitions in Section 6-8-3-020 shall apply to all plumbing systems, including those in one- and two-family dwellings. The maximum water consumption flow rates and quantities for all plumbing fixtures and fixture fittings shall be in accordance with Table 6-8-3-020. Exceptions: 1. Blowout design water closets having a water consumption not greater than 3.5 gallons (13 L) per flushing cycle. 2. Vegetable sprays. 3. Clinical sinks having a water consumption not greater than 4.5 gallons (17 L) per flushing cycle. 4. Laundry tray sinks and service sinks. 5. Emergency showers and eye wash stations. _____ TABLE 6-8-3-020 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS Plumbing Fixture or Fixture Fitting | Maximum Flow Rate or Quantity Lavatory faucet and replacement aerators, private | WaterSense Labeled and 1.2 gpm at 60 psi Lavatory faucet, public (metering) | 0.25 gallon per metering cycle Lavatory, public (other than metering) | 0.5 gpm at 60 psi Shower head | WaterSense Labeled and 2.0 gpm at 80 psi Kitchen faucet and replacement aerators | 1.8 gpm at 60 psi Urinal | 0.5 gallon per flushing cycle Water closet | 1.28 gallons per flushing cycle _____ a. A hand-held shower spray is a shower head. As point of clarification, multiple shower heads may be installed in a single shower enclosure so long as each shower head individually meets the maximum flow rate, the WaterSense requirements, and the U.S. Department of Energy definition of a shower head. However, multiple shower heads are not recommended for water efficiency purposes. b. Consumption tolerances shall be determined from reference standards. c. For flushometer valves and flushometer tanks, the average flush volume shall not exceed 1.28 gallons. d. For single flush water closets, including gravity, pressure and electro-hydraulic tank types, the average flush volume shall not exceed 1.28 gallons. e. For dual flush water closets, the average flush volume of two reduced flushes and one full flush shall not exceed 1.28 gallons. f. See 2014 GA Amendment to Section 301.1.2 of the International Plumbing Code titled "Waiver from requirements of high efficiency plumbing fixtures." g. Kitchen faucets are permitted to temporarily increase the flow above the maximum rate, but not to exceed 2.2 gpm (8.3 L/m) at 60 psi (414 kPa) and must revert to a maximum flow rate of 1.8 gpm (6.8 L/m) at 60 psi (414 kPa) upon valve closure. B. Clothes Washers. Residential clothes washers shall be accordance with the Energy Star Program requirement. C. Cooling Tower Water Efficiency. 1. Once-Through Cooling. Once-through cooling using potable water is prohibited. 2. Cooling Towers and Evaporative Coolers. Cooling towers and evaporative coolers shall be equipped with make-up water and blow down meters, conductivity controller, and overflow alarms. Cooling towers shall be equipped with efficiency drift eliminators that achieve drift reduction to 0.002 percent of the circulated water volume for counterflow towers and 0.005 percent for crossflow towers. 3. Cooling Tower Make-up Water. Water used for air conditioning, cooling towers shall not be discharged where the hardness of the basin water is less than 1,500 mg/L. Exception: Where any of the following conditions of the basin water are present: total suspended solids exceed 25 ppm, CaCO3 exceeds 600 ppm, chlorides exceeds 250 ppm, sulfates exceed 250 ppm, or silica exceeds 150 ppm. D. Landscape Irrigation System Efficiency Requirements. The requirements apply to all new landscape irrigation systems connected to the public water system except those: (a) used for agricultural operations as defined in O.C.G.A. § 1-3-3, (b) used for golf courses, and (c) dependent upon a nonpublic water source. Nothing in this code is intended to require that landscape irrigation systems must be installed at all premises. The landscape irrigation efficiency requirements apply only when someone voluntarily chooses or is otherwise required by some requirement beyond this code, to install a landscape irrigation system on premises. 1. Avoiding Water Waste Through Design. All new landscape irrigation systems shall adhere to the following design standards: a. Pop-up type sprinkler heads shall pop-up to a height above vegetation level of not less than four inches above the soil level when emitting water. b. Pop-up spray heads or rotary sprinkler heads must direct flow away from any adjacent surfaces and must not be installed closer than four inches from impervious surfaces. c. Areas less than ten feet in width in any direction shall be irrigated with subsurface irrigation or by other means that produces no overspray or runoff. d. Narrow or irregular shaped landscaped areas, less than four feet in any direction across opposing boundaries, shall not be irrigated by any irrigation emission device except subsurface or low flow emitters with flow rates not to exceed 6.3 gallons per hour. 2. Landscape Irrigation System required Components. All new landscape irrigation systems shall include the following components: a. A rain sensor shut-off installed in an area that is unobstructed by trees, roof over hangs, or anything else that might block rain from triggering the rain sensor shut-off. b. A master shut-off valve for each controller installed as close as possible to the point of connection of the water but downstream of the backflow prevention assembly. c. Pressure-regulating devices, such as valve pressure regulators, sprinkler head pressure regulators, inline pressure regulators, WaterSense spray sprinkler bodies, or other devices shall be installed as needed to achieve the manufacturer's recommended pressure range at the emission devices for optimal performance. d. Except for landscape irrigation systems serving a single-family home, all other systems must also include: 1. A WaterSense irrigation controller; and 2. At least one flow sensor, which must be installed at or near the supply point of the landscape irrigation system and shall interface with the control system, that when connected to the WaterSense controller will detect and report high flow conditions to such controller and automatically shut master valves. The flow sensor serves to aid in detecting leaks or abnormal flow conditions by suspending irrigation. High flow conditions should be consistent with manufacturers' recommendations and specifications.

(Ord. No. 8352, 10/11/23, § 1)

Ask a question about Marietta law

Corpus searches the Marietta sections it holds and shows the ones that match, with their citations. Free, no sign-in.