For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 22-267 — Determination of charges

Code of the City of Rome, Georgia (Part III) (Codified through Ordinance No. 26-01-02, adopted January 26, 2026. (Supp. No. 28)) · Rome Municipal Code § 22-267

Corpus is an independent public-information project, not the official City of Rome website. Stable reference: corpuslaw.us/code/ef4b9236-0e2c-485a-8e77-fa335d06c272

Sec. 22-267. - Determination of charges.

(a) Generally. The wastewater characteristics which are used to determine user charges are BOD, suspended solids, flow volume, and grease. Persons and industrial users which discharge normal strength wastewaters shall be charged a base user charge in which flow volume is the wastewater characteristic for determining the charge. When BOD, suspended solids, or grease concentrations in a user's wastewater discharge are in excess of the range of concentration in normal strength wastewater, a surcharge shall be added to the base charge. (b) Base charge. The formula for determining the base user charge which applies to normal strength discharges shall be as follows: R = V m C t R | = | Monthly user charge V m | = | Monthly volume contribution from a user in 1,000 gallon units C t | = | Basic unit charge to user (dollars per 1,000 gallons for operation and maintenance) (c) Surcharges. When BOD, suspended solids, and grease exceed the range of concentration of those pollutants in normal strength wastewater, a surcharge shall be added to the basic charge. The surcharge shall be determined as follows: C;sub§\sub; = 0.000692 (B c × B + S c × S + G c × G) V u C;sub§\sub; | = | Surcharge for wastewater (dollars per month) B c | = | Operation and maintenance costs for treatment of a pound of BOD B | = | Concentration of BOD from a user above base load (mg/l) S c | = | Operation and maintenance costs for treatment of a pound of suspended solids V u | = | Flow volume in units of 1,000 gallons per year S | = | Concentration of suspended solids from a user above base level (mg/l) G c | = | Operation and maintenance costs for treatment of a pound of grease G | = | Concentration of grease from a user above base level (mg/l) 0.000692 | = | Conversion factor from measured units to dollars per month (d) Unit value determination. (1) The basic unit C t , which shall be revised biennially, shall be determined as follows: C t = B d B c = S d; \ sub§sub;c + G d G c + V c B d | = | Average pounds of BOD per 1,000 gallons of normal strength wastewater contributed S d | = | Average pounds of suspended solids per 1,000 gallons of normal strength wastewater contributed G d | = | Average pounds of grease per 1,000 gallons of normal strength wastewater contributed V c | = | Operation and maintenance cost for treatment of flow volume in 1,000 gallon units C t | = | B c , S c , and G c are as defined in subsection (c). (2) B d , S d , and G c shall be revised not less frequently than biennially and shall be determined by either: a. Dividing actual wastewater treatment plant loading less total surcharged loading by total annual volume contribution by domestic wastewater dischargers; b. Actual sampling of domestic wastewater dischargers; or c. Utilizing wastewater treatment plan design capacity for average concentration. 1995 values for these normal loadings are as follows: B d = 1.96 pounds per thousand gallons S d = 1.67 pounds per thousand gallons G d = 0.83 pounds per thousand gallons (3) V c , B c , S c and G c shall be revised not less often than every two years by dividing their respective annual maintenance and operation costs by their respective annual loadings. 1995 values for these unit costs are as follows: V c = $0.178 per thousand gallons B c = $0.032 per pound S c = $0.032 per pound G c = $0.029 per pound (4) Wastewater monitoring and reporting shall be as described in division 6. (5) Wastewater discharge of volume (V m ) for dischargers of normal strength wastewater shall be 100 percent of the amount of water metered. For industrial wastewater dischargers which discharge surcharged waste, the wastewater discharge volume (V u ) shall be 80 percent of the amount of water metered unless it can be shown that the volume of wastewater discharged is less.

(Ord. No. 96-7-2, 7-22-96)

Ask a question about Rome law

Corpus searches the Rome sections it holds and shows the ones that match, with their citations. Free, no sign-in.