§ 5.3.1 — Requirements applying to signs in all zoning districts
Code of the City of Rome, Georgia (Part III) (Codified through Ordinance No. 26-01-02, adopted January 26, 2026. (Supp. No. 28)) · Rome Municipal Code, App. B, art. 5, § 5.3.1
Corpus is an independent public-information project, not the official City of Rome website. Stable reference: corpuslaw.us/code/bf70297f-069f-4382-8971-8cc94b4957db
5.3.1. - Requirements applying to signs in all zoning districts.
a. Conformance to Other Codes. (1) A permit shall be obtained from the Building Inspections Department prior to installation or placement of any free-standing sign having a sign structure area greater than 15 square feet or any building sign having a sign face area greater than six square feet. All signs for which a building permit is required shall be constructed and maintained in conformance with all Building Code and Electrical Code requirements. (2) Plans required for issuance of a building permit for a sign shall be certified as to conformance with all structural and wind-load resistive standards of the Building Code by a structural engineer registered in the State of Georgia, or be prepared using standard drawings prepared by a structural engineer or other qualified professional meeting or exceeding all requirements of the Building Code. These provisions are excluded from any sign printed or affixed to a wall and/or pylon signs of less than 32 square feet or less than six feet tall. (3) All signs involving internal lights or other electrical devices or circuits shall display a label certifying it as being approved by the Underwriter's Laboratories, Inc. No electric sign may be installed that is not approved by the Underwriter's Laboratory, Inc. Each sign manufacturer's UL# and the UL#s of each individual sign must be provided as part of the sign permit application to prevent non-UL signs from being installed. (4) All electrical service to a sign shall be in compliance with the Electrical Code. (5) Clearance from all electrical power lines shall be in conformance with the requirements of the Electrical Code. b. Sign Maintenance. All signs, together with all their supports, braces, guys, and anchors shall be kept in good repair and, unless constructed of galvanized or non-corroding metal, shall be given a protective coating as necessary to maintain a clean appearance and safe condition. c. Principal Free-standing Signs. (1) Each principal free-standing sign shall be located at least 75 feet from any other free-standing sign on an adjacent property on the same side of the street. This distance may be reduced upon approval by the Chief Building Official if it cannot be met due to the location of existing signs on separate but adjoining lots. Such reduction shall be the minimum required in order to maintain the greatest separation possible from such existing signs. (2) Principal free-standing signs shall be located at least 37 feet from a side lot line, or one-half the width of the lot frontage, whichever is less, except on intersecting corners of corner lots where the setback must be ten feet from each side. A site drawing must be prepared and provided the Building Inspection Department when applying for a permit. (3) A minimum of 25 square feet of landscaped area, exclusive of the sign structure, shall be located at the base of each principal freestanding sign. The landscaping shall consist of shrubs, ground covers, or other plants appropriate to the setting of the sign. This requirement is the responsibility of the property owner or tenant, not the sign company. (4) There shall be a minimum of ten feet between any street right-of-way line and the nearest edge of a principal freestanding sign. Monument signs over 36 inches in height must be set back at least 20 feet from any street right-of-way. d. Projecting, Awning, and Canopy Signs. (1) Over Private Property: Projecting, awning, and canopy signs shall provide at least eight feet of clearance above the ground when erected over pedestrian walkways on private property and 17 feet of clearance when erected over driveways or other areas used for vehicles. Suspended canopy signs shall be at least four inches from the building face and at least eight inches from the edge of the canopy. [image omitted; see the official code] Canopy Sign (2) Over Public Property: Projecting, awning, and canopy signs that project over public property, such as a sidewalk along a public street, shall maintain a clear height of nine feet and shall extend not more than within 18 inches of the back of curb. (3) Projecting and canopy signs shall be limited to no more than one per tenant on a property, and each tenant shall have no more than one projecting sign or canopy sign. (4) These requirements exclude overhanging "Clearance Signs" over private drives used to warn drivers of low clearances under canopies, covered delivery/pickup area, etc. e. Banners. Banners shall be allowed only as wall or window signage and shall be placed flush upon the wall or window to which it is attached. Banners shall not be hung as canopy signs, flown as flags, or used as any other form of sign. In addition to any other signage allowed, one (1) banner per street frontage is allowed. Area of banner shall not exceed 32 square feet. f. Conformance with State Law. Any sign within 660 feet of a State or U.S. numbered highway that advertises or offers anything for sale or lease that is not located on the property where the sign is located must be zoned for commercial or industrial use, and must conform to the regulations of the Georgia Dept. of Transportation. For sign clearances under conductors or high tension lines of over 600 volts, see the National Electric Safety Code, ANSI C2-1996, Part 2, Safety Rules for Overhead Lines, Articles 234B1 through 234A3 which must be met. g. Enforcement by Permit Number. With each permit issued under this Article, the Building Inspection Department shall issue a sticker bearing the same number(s) of the permit with which it is authorized (in One-Inch Numbers), to be affixed in the corner area of the sign nearest the street, so as to be easily seen. The absence of a proper sticker on a sign erected subsequent to the passage or adoption of this Code, shall be prima facie evidence that the sign has been erected in violation of the provisions of this Ordinance.
Ask a question about Rome law
Corpus searches the Rome sections it holds and shows the ones that match, with their citations. Free, no sign-in.
