§ 8.2.7 — Buildings
Code of Ordinances of the City of Roswell, Georgia (Codified through Ordinance No. 2025-11-10, adopted November 10, 2025. (Supp. No. 17)) · Roswell Unified Development Code § 8.2.7
Corpus is an independent public-information project, not the official City of Roswell website. Stable reference: corpuslaw.us/code/13c63f57-75e7-4467-aa2b-7e47cc6a6b95
8.2.7. - Buildings
A. The building types allowed in a Protected View Zone, the maximum façade width in a Protected View Zone, and maximum allowed principal building heights are established and required by regulating character areas as follows: Regulating Character Area | Building Types Allowed in a Protected View Zone | Facade Width in a Protected View Zone | Principal Building Height In a Protected View Zone | Not in a Protected View Zone Bulloch Avenue | Per regulating character area | All: Max. 60 ft. | Max. 2 stories | Max. 3 stories Mill Village | Per regulating character area | All Houses: Max. 60 ft. Other: Max 170 ft. | Max. 2 stories | Max. 3 stories Mimosa Boulevard | Per regulating character area | All Houses: Max. 60 ft. Other: No max. | Max. 2 stories | Max. 3 stories South Alpharetta/ Atlanta Street; North Alpharetta/ Atlanta Street | Per UDC | All: Max. 200 ft. | Facades 80 feet or less in width: max. per UDC plus a required stepback | Per UDC Facades over 80 feet in width: max 2 stories Central Alpharetta/ Atlanta Street | Per regulating character area | All: Max. 100 ft. | Max. 2 stories | Per UDC Lower Canton Street | Per regulating character area | All: Max. 70 ft. | Max. 2 stories | Max. 3 stories Upper Canton Street | Per regulating character area | All: Max. 70 ft. | Max. 2 stories | Max. 3 stories B. Protected View Zone, as used above, means the portion of a site that includes: 1. The area between the primary street right-of-way and a line 40 feet past the required primary street setback; and 2. The area between the side street right-of-way and a line 25 feet past the required side street setback. 3. In calculating the above, the setbacks shown on the Historic District Regulating Plan will be used. When a site is not subject to the Historic District Regulating Plan, the minimum setback required by the UDC will be used. [image omitted; see the official code] C. Building Types Allowed in Protected View Zone. When the table in "A" above establishes allowed building type in a Protected View Zone "per regulating character area", all portions of new buildings in a Protected View Zone must match one of the building types present on an officially designated historic building in the same regulating character area. For the purpose of this requirement only, detached houses, attached houses, commercial houses, and cottage courts are considered to be the same "house" building type. D. Façade width in a Protected View Zone. 1. When the table in "A" above establishes façade widths in a Protected View Zone, this refers to the street-facing width of a single building along a single street (measured perpendicular to the right-of-way of such street). When a building faces multiple streets, the width is calculated separately per street. 2. All street-facing building facades along the same street and on the same lot are considered a single building for the purpose of these façade width requirements, unless one or more of the following occurs: a. The facades are located on separate buildings (per building code) and a minimum separation of 10 feet exists between all portions of such buildings in a Protected View Zone; or b. The facades are located on a single building (per building code) and an at-grade open space with a minimum width of 10 feet and a minimum depth of 30 feet is provided between adjacent facades. [image omitted; see the official code] E. Stepback in a Protected View Zone. 1. When the above table requires a stepback in a Protected View Zone, all stories above the second must be set back at least 10 feet behind the street-facing facade of the second story. This is only for the South Alpharetta/Atlanta Street character area and the North Alpharetta/Atlanta Street character area. This means that in these character areas within the protected view zone, a building may have three stories, but the third story must contain a stepback of ten feet above the second story when the façade is 80 feet in width or less. A façade that is over 80 feet in width has a maximum of two stories in the protected view zone. 2. When a Protected View Zone contains portions of two or more buildings (one in the front and one in the rear), the requirement of "1" above does not apply to facades on rear building that are fully screened by the front building (vertically and horizontally) from view from the public right-of-way. F. Neighborhood compatibility bulk planes required by the underlying zoning district regulations apply in the -HD.
(Ord No. 2020-03-02, § 3, 3-9-2020)
Ask a question about Roswell law
Corpus searches the Roswell sections it holds and shows the ones that match, with their citations. Free, no sign-in.
