For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 22-34 — Sprinkler protection requirements

Code of Ordinances of the City of Sandy Springs, Georgia (Codified through Ordinance No. 2026-03-006, enacted March 17, 2026 (Supp. No. 24)) · Sandy Springs Code of Ordinances § 22-34

Corpus is an independent public-information project, not the official City of Sandy Springs website. Stable reference: corpuslaw.us/code/d9fe7b32-805d-4a85-9a7b-93cf6515073f

Sec. 22-34. - Sprinkler protection requirements.

(a) Definitions. The following words, terms and phrases, when used in this section, shall have the meanings ascribed to them in this subsection, except where the context clearly indicates a different meaning: Approved system, commercial, means a sprinkler system used for areas less than 5,000 square feet; for light hazard areas (i.e., offices and shipping areas of commercial buildings less than 10,000 square feet), a modified sprinkler system may be used. This system may be used upon approval by the City Fire Marshal. Approved system, commercial/residential, means a sprinkler system designed in accordance with National Fire Protection Association standards and referenced publications, for commercial buildings over 5,000 square feet, for light hazard areas occupancies of less than 10,000 square feet, or residential structures, or those structures required to be sprinkled by some other code. New means any additions to existing buildings, whether vertically or horizontally, or any existing building or structure which shall be deemed to be a new building in the event such building, or structure is subject to substantial renovation, a fire or other hazard of serious consequence, change in the classification of occupancy or a change to the occupant load or structure issued as a condition of occupancy. For purposes of this definition, the term "substantial renovation" shall mean any construction project involving egress or internal features of such building or structure costing more than the building's or structure's gross assessed value (50 percent for all multifamily residential structures) according to county tax records at the time of such renovation. For the purposes of this section, the gross assessed value standard shall be calculated for each individual building or structure being renovated, and not the gross assessed value of a multi-building development which is contained in a single tax parcel. Any requirements of this section triggered by substantial renovation under this definition shall apply solely to the individual building or structure being renovated. Notwithstanding the foregoing, any requirements of this section triggered by substantial renovation to an individual building or structure contained within a larger multi- building development on a single tax parcel, when such renovation costs more than the gross assessed value (50 percent for all multifamily residential) of the entire multi-building development, shall apply to the entire multi-building development. (b) Protection system required; exceptions. All new commercial buildings in excess of 5,000 square feet, light hazard occupancies, e.g. business or retail, of less than 10,000 square feet, or with an occupant load greater than 100 persons shall be protected throughout with an approved automatic fire protection system, except as follows: (1) For buildings less than 15,000 square feet constructed mainly for the storage of products with limited life loss potential some flexibility may be allowed. The owner may petition to the fire marshal for exception to sprinklers in the storage areas. The fire marshal will give consideration to such things as building construction, products stored, arrangement of storage, number of employees in the area, access to the building, and any other fire protection features provided. This exception will not be allowed for additions to existing sprinkled buildings. (2) For buildings storing materials that are water reactive or may be damaged by water fighting a fire, than by a fire, the fire marshal's office shall use the same considerations. (3) Additions to existing unprotected buildings where the addition totals less than 1,000 square feet; provided, however, the addition must be separated by a two-hour fire barrier in accordance with the city building code and is not required to be protected by some other applicable code. (4) All new multifamily residential structures shall be protected throughout with an approved automatic fire protection system in accordance with National Fire Protection Association Standards as adopted by the office of the insurance and safety fire commissioner. (5) All new one-family and two-family dwellings with a fire separation distance of less than 20 feet from another dwelling structure, or closer than ten feet to the property line, must be sprinkled with an approved automatic fire protection system in accordance with NFPA 13D as adopted by the office of the insurance and safety fire commissioner in the kitchen and fuel fired equipment rooms. (6) There shall be early fire detection systems in all sections of multifamily occupancies as required by the International Property Maintenance Code. All new multifamily structures shall include a hardwired early fire detection system. Existing buildings may have an approved battery operated smoke detector. The fire marshal may require a hard-wire detection system if battery operated detectors are not maintained according to manufacturer's recommendation. (7) The owner is responsible for the inspection and testing of the sprinkler system in accordance with the rules of the state safety fire commissioner on all structures required to have sprinkler systems pursuant to this Code. If this section in any way conflicts with the provisions in the International Building Code, the fire prevention code, or the life safety code, the more restrictive shall apply.

(Ord. No. 2006-11-86, § 1.11, 11-8-2006; Ord. No. 2016-12-37, § II, 12-6-2016; Ord. No. 2022-11-18 , § I, 11-1-2022; Ord. No. 2025-07-12, § I, 7-15-2025)

Ask a question about Sandy Springs law

Corpus searches the Sandy Springs sections it holds and shows the ones that match, with their citations. Free, no sign-in.