Sec. 22-47. - Identification.
(a) Every existing building and all new buildings shall be accessible to fire department apparatus by way of designated fire lanes with an all-weather driving surface of not less than 20 feet of unobstructed width. There shall be a minimum roadway outside the turning radius at the curb of 40 feet. There shall be a minimum vertical clearance of 13 feet by six inches. Any dead-end fire department access roadway in excess of 150 feet in length shall include a turnaround at the closed end conforming to county construction standards and specifications, latest edition. The minimum hard surface sub-base paving specification shall be at 1½ inches of asphalted topping on at least six inches of bound crushed stone, or the equivalent, capable of supporting the gross vehicle weight of fire apparatus. During construction, when combustibles are brought onto the site in such quantities as deemed hazardous by the fire official, access roads and a suitable temporary supply of water acceptable to the fire department shall be provided and maintained. (1) Where fire protection systems approved by the fire official are provided, the clearances required in this subsection (a) may be modified by the fire official. (2) The fire official shall have the authority to require an increase in the minimum access widths where they are inadequate for fire or rescue operations. (3) The creation, deletion, or modification of a fire lane shall be done in the best professional judgment of the fire official. (b) Any owner of a building aggrieved by the decision of the fire official under this section may appeal from the decision of the fire official to the city manager within 30 days from the date of the fire official's decision. All appeals to the city manager shall be in writing setting forth the reasons for the appeal. The city manager shall issue a written decision to the owner within 30 days from the receipt of the written appeal from the owner. (c) The areas designated as fire lanes shall have signs posted meeting the following criteria: (1) Signs to read "No Parking Fire Lane." (2) Letters shall not be less than two inches in height. (3) One sign shall be posted at the beginning of the fire lane and one at the end of the fire lane; each sign shall be erected not more than 50 feet apart. (4) Signs posted shall not be more than four feet from the edge of the curb and shall be visible from both direction of the driving surface. (d) The fire official may order curbs to be painted yellow or other distinctive colors.
(Ord. No. 2006-11-86, § 3.3, 11-8-2006)
Ask a question about Sandy Springs law
Corpus searches the Sandy Springs sections it holds and shows the ones that match, with their citations. Free, no sign-in.