§ 3.4.3 — RM- Height and Mass

Code of Ordinances of the City of Sandy Springs, Georgia (Codified through Ordinance No. 2026-03-006, enacted March 17, 2026 (Supp. No. 24)) · Sandy Springs Development Code § 3.4.3

Corpus is an independent public-information project, not the official City of Sandy Springs website. Stable reference: corpuslaw.us/code/e71c47ec-218f-490b-98bc-532d4e8ebccb

Sec. 3.4.3. - RM- Height and Mass

SEC. 3.4.3. RM- HEIGHT AND MASS [image omitted; see the official code] Building Height [image omitted; see the official code] | Base: maximum height RM-3, RM-3/8 | 3 stories/ 44' max Adjacent to RE- or RD- | 3 stories/ 42' max Within a transition area | 2 stories/ 28' max Bonus: maximum height (see Div. 6.7) RM-3/8 | 8 stories/ 112' max Adjacent to RE- or RD- | 8 stories/ 104' max Within a transition area | 2 stories/ 28' max Story Height [image omitted; see the official code] | Ground floor elevation | 2' min/ 5' max [image omitted; see the official code] | Ground story | 12' min Building Mass [image omitted; see the official code] | Street-facing building length | 200' max

(Ord. No. 2023-12-21, § I(Att. A), 12-5-2023)

Ask a question about Sandy Springs law

Corpus searches the Sandy Springs sections it holds and shows the ones that match, with their citations. Free, no sign-in.