Sec. 6.6.2. - Building Design

A. Color Primary or fluorescent colors are not permitted except on sign faces, awnings, canopies or as accent colors (not to exceed 10% of each building or canopy façade exclusive of window and door areas) on any side of the building. B. Architectural Treatment 1. Exempt Exterior building walls, decorative elements, parapets and cornices are exempt from the architectural treatment requirements when they meet the following conditions: a. When the exterior wall is not visible from any public or private street; and b. The exterior wall does not include a public entrance. 2. Prohibited a. Prohibited exterior building materials include: i. [Reserved]; ii. Non-architectural metal panel systems; iii. Unfinished cast-in-place or precast concrete vertical elements, e.g., walls, columns, exposed elevated slab edges (except as noted in Sec. 6.6.2 B.3.b.vii, below); iv. Exposed standard concrete masonry units (CMU); v. Softwood plywood grade B or lower, oriented-strand board and particle boards; or vi. Vinyl siding. b. Prohibited exterior building components, include: steel gates, burglar bars and roll-down security curtains. Interior security measures are not regulated. 3. Required a. All exterior walls (not including windows and doors) for all new construction must consist of 1 or a combination of the following durable materials in the quantity required below: i. Up to 10 vertical feet from grade: 100% durable materials; and ii. Remaining building height: minimum 70% durable materials. b. Durable materials include: i. Clay brick; ii. Ceramic and porcelain tile; iii. Dressed stone with rusticated, flamed, honed, polished, bush-hammered or other standard face finish; iv. Traditional cement stucco (real stucco); v. Architectural concrete masonry units (CMU) with fluted, split-face, ground, glazed or other architectural finish; painted standard CMU is not an acceptable finish; vi. Portland cement plaster and lath systems; vii. Architectural (either cast-in-place, pre-cast or tilt-up) concrete with a finish proposed by the architect and approved by the Director; viii. Fiber cement-board, painted; or ix. Exterior Insulation and Finish Systems (EIFS) which employ a high-impact mesh as a system component. c. Sloped roofs (pitch greater than 2:12) must be standing seam metal, slate, concrete or metal roof tiles or composition shingles. A decorative parapet or cornice must be constructed along all flat roof lines (i.e., roofs with slopes less that 2:12). d. Alternate materials may be approved for use by the Director, provided they are considered equivalent or better than the listed materials. C. Building Articulation 1. Articulation in Building Height For buildings 100 feet or more in length, at least 15% of the street-facing roof line must have a variation in height of at least 5 feet. On a corner lot, the variation in height must be located at the corner of the building that addresses both street fronts. A parapet that meets the requirements of this Development Code may be counted toward this articulation requirement. Signs are not allowed above the roof line, and do not count toward this articulation requirement. [image omitted; see the official code] 2. Articulation in Building façade a. For buildings 100 feet or more in length, at least 2 portions of the street-facing building façade must have a variation in setback of at least 2 feet. The combination of the required variations in setback must total no less than 15% of the length of the building. b. The Director may require contrasting colors or materials must be used on the primary façade and abutting façade setbacks to emphasize the articulation and variation along the street-facing building façade. [image omitted; see the official code] D. Ground Floor Retail Tenant Size In the City Springs and Perimeter Districts, no ground floor retail tenant may occupy more than 30,000 contiguous rentable square feet. No variances to this standard are allowed; however, the Director may approve renovation of existing tenant spaces so long as the renovation does not increase the gross square footage of an existing tenant space. E. Commercial-Active Space Where required by the zoning district or use. the ground story must be constructed to meet or exceed the minimum requirements for ground floor elevation, ground story height. transparency. and entrance spacing required for a retail or commercial use. Commercial-active space is restricted to only commercial use. F. Commercial-Ready Space Where required by the zoning district or use, the ground story must be constructed to meet or exceed the minimum requirements for ground floor elevation, ground story height, transparency, and entrance spacing required for a retail or commercial use. Commercial-ready space is allowed to be occupied by any use allowed in the zoning district.

(Ord. No. 2023-12-22, § I(Att. A), 12-5-2023; Ord. No. 2025-09-22, § I, 9-16-2025)

Ask a question about Sandy Springs law

Corpus searches the Sandy Springs sections it holds and shows the ones that match, with their citations. Free, no sign-in.