Sec. 7.8.5. - EV Charging Facility

A. Defined A facility that provides electric vehicle infrastructure for the purpose of charging electric vehicles as an accessory to another primary use. 1. Charging Level The standardized indicators of electrical force, or voltage, at which an electric vehicle's battery is recharged: a. Level 1 The slowest type of charging equipment plugs directly into a standard 120-volt AC outlet supplying an average power output of 1.3 kW to 2.4 kW. b. Level 2 Considered medium charging; typically requires a 40-100 amp breaker on a 240-volt AC circuit. c. Level 3 or greater Considered rapid charging; typically requires a 60 amp or higher dedicated breaker on a 480-volt or higher 3-phase circuit with special grounding equipment. DC fast charging uses an off-board charger to provide the AC to DC conversion, delivering AC directly to the car battery. 2. Electric Vehicle Infrastructure The structures, machinery, and equipment necessary and integral to supporting an electric vehicle, including the electrical conduit and wiring requirements for the installation of electric vehicle charging equipment. B. Exempt The following EV charging facilities are exempt from these regulations: 1. Single Unit Residential Charging facilities located on single unit detached or attached lots designated as private, restricted use only. All installations must comply with the placement and screening requirements of mechanical equipment found in Sec. 6.1.2 B.3 and Sec. 8.3.9. 2. Enclosed in Parking Structure Any EV charging facilities located within an enclosed parking structure or garage. These installations must comply with the signs and maintenance requirements below. C. Basic Use Standards 1. Signs a. Signs must be posted identifying voltage and amperage levels and use, fee, and safety information related to the EV charging facility. b. Signs must be posted at public EV charging facilities indicating that the space is reserved for EV charging purposes only. For purposes of this provision, "charging" means that an electric vehicle is parked at an EV charging facility and connected to the battery charging station equipment, otherwise known as "actively charging." c. Prohibited signs (Sec. 8.4.3) are not allowed. d. Level 2 charging facilities must have no more than 25% of the total charger used for signs or an otherwise illuminated display. Level 2 charging facilities do not require a sign permit but will instead be verified as a part of the building permit. This sign percentage requirement does not apply when the charger is located within a parking structure or garage. e. Level 3 or greater charging facility must have no more than 50% of the total charger used for signs or otherwise illuminated display. Level 3 or greater charging facilities do not require a sign permit but will instead be verified as a part of the commercial building permit. This sign percentage requirement does not apply when the charger is located within a parking structure. 2. No portion of the EV charging facility can impede pedestrian, bicycle, or wheelchair movement, or create a safety hazard. 3. EV charging facilities, including electrical transformers and other mechanical equipment associated with the charger, must conform to any applicable screening requirements in Sec. 8.3.9. 4. All proposed or improved on-street parking is required to install conduit for future EV charging facilities. 5. A Level 2 charging facility must be no wider than 24 inches at any point, not including the plug handle, hook, hose, and related components. 6. A group of 6 or more Level 3 or greater EV charging facilities is considered a designation EV installation and must be an accessory to a primary retail use. 7. An EV charging facility must be located a minimum of 10 feet from the build-to zone. In Perimeter Districts, the charger must be located a minimum of 20 feet from the build-to zone. 8. A masonry wall may count toward the minimum build-to requirement of the District provided the following standards are met: a. The building must meet the minimum width requirements of Sec. 6.1.2 C.5; b. The masonry wall must have openings meeting the transparency requirements of Div. 6.3 and must provide similar architectural elements to the building, such as materials, cornices, and awnings; and c. The masonry wall is not required to meet the minimum story requirement of the district so long as the wall is a minimum of 12 feet in height. 9. EV charging facilities must be maintained, including the functioning of the equipment. A phone number or other form of contact information must be provided on the equipment to report when it is not functioning, or other problems are encountered. 10. EV charging facility canopies must be architecturally integrated with any associated commercial building on the site and not include any signs. Canopy support columns must be fully encased with masonry materials that are complementary to those used on the main building. The canopy band face must be of a color consistent with that of the main structure or an accent color. Primary or fluorescent colors must not exceed 10% of each canopy band face. 11. No charging facility may be located within 50 feet of the lot line of a Protected Neighborhood. 12. Existing Fuel Pumps or Fuel Stations Level 2 charging facilities may be installed at existing fuel pumps on existing parking spaces, so long as they are at least 10 feet from any build-to zone. Level 3 or greater charging facilities may replace existing fuel pumps on a site.

(Ord. No. 2023-12-23, § I(Att. A), 12-5-2023)

Ask a question about Sandy Springs law

Corpus searches the Sandy Springs sections it holds and shows the ones that match, with their citations. Free, no sign-in.