§ 8.2.8 — Parking Layout and Design
Code of Ordinances of the City of Sandy Springs, Georgia (Codified through Ordinance No. 2026-03-006, enacted March 17, 2026 (Supp. No. 24)) · Sandy Springs Development Code § 8.2.8
Corpus is an independent public-information project, not the official City of Sandy Springs website. Stable reference: corpuslaw.us/code/58dc9f9b-33ac-4414-b1a7-a95eec2266a7
Sec. 8.2.8. - Parking Layout and Design
A. Access All on-site parking must be arranged so that no vehicle is forced to back out on a public street or forced to use a street, not including an alley, to gain access from 1 parking aisle to another parking aisle. The City's uninterrupted ingress/egress regulations apply to parking lot design (see Technical Manual Sec. 3: Roadway Design and Pavement). B. Parking Space and Aisle Specifications 1. Dimensions Parking spaces and drive aisles must meet the following dimensions in both surface parking lots, on-street parking and in parking structures. [image omitted; see the official code] a. A median island must be provided between every 6 single parking rows. b. Parking spaces and drive aisles using dimensions other than those specified may be approved if prepared and sealed by a design professional licensed in the State of Georgia with expertise in parking facility design, subject to approval by the Director. 2. Compact Parking a. Compact car parking spaces may be used in place of a standard size parking space. The total number of compact car parking spaces may not exceed 15% of the total number of required parking spaces. b. No more than 2 compact parking spaces may be placed side by side. Compact spaces may be reduced to 8 feet in width and 16 feet in depth. All compact parking spaces must be clearly and visibly striped and labeled for compact car use only. C. Accessible Parking Accessible parking spaces must be provided in accordance with the requirements of the Americans with Disabilities Act (ADA) (Public Law 101-136), the State Building Code, and the American National Standards Institute. See the Sandy Springs Technical Manual for further guidance. D. Electric Vehicles In the Perimeter Center and City Springs Districts, and in any parking structure constructed in any other district, 5% of all parking spaces must be electric-vehicle (EV) ready, with a minimum of 2 EV-ready spaces for all parking lots over 20 spaces. Electric-vehicle ready means conduit or other means to connect power to each space is installed in advance. E. Reserved Parking Parking spaces may be reserved for a specific tenant or unit, provided that the following standards are not exceeded. 1. Residential a. One space per efficiency or one-bedroom multi-unit dwelling. b. Two spaces per 2-bedroom or greater multi-unit dwelling. 2. Nonresidential No more than ⅓ of the total provided spaces may be reserved. F. Parking Lot Landscaping All on-site surface parking lots must be landscaped as specified in Sec. 8.3.2. G. Visibility at Intersections No parking or loading area may interfere with the safe operations of all users at any intersection or along any roadway. H. Surfacing 1. Parking and loading areas must be surfaced with concrete, asphaltic concrete, asphalt, or other dust-free surface. 2. Surface parking spaces on lots or sites containing more than the minimum number of spaces required by this Division must be of pervious material for any spaces beyond the minimum required. 3. Porous pavement material may be substituted for standard dust-free pavements subject to the approval of the Director. Permitted materials include, but are not limited to, grass, "grasscrete," ring and grid systems used in porous or grid pavers. I. Curbs and Drainage 1. Parking and loading areas must be graded and drained to collect, retain and infiltrate surface water on-site so as to prevent damage to abutting properties or public streets. 2. Curbing or parking block must be installed as required by the Director. Curbing must have openings to allow drainage to enter and percolate through landscaped areas. J. Lighting Parking and loading area lighting must be installed in accordance with the Sandy Springs Technical Manual. K. Parking Structures 1. All stories of structured parking must be screened so that cars are not visible from adjacent property, adjacent streets (not including alleys), or other public property. 2. Exterior elevations for parking floors must appear horizontal, even where ramps occur within the building. 3. Green walls, vertical gardens, architectural grilles, louvers, or opaque material that continues to allow natural ventilation is required to screen any vehicles from view from adjacent public streets or sidewalks. Where at least 10 feet of planting area exists between the street and the parking structure, the Director may approve a landscape area using berms, trees and shrubs in a way that constitutes an equivalent or better screen. 4. Elevator and stair shafts must be topped with an architectural accents using materials, colors, design or other features similar to that of the principal building it serves. 5. A digital sign demonstrating the remaining spaces available in real-time must be placed at the entrance to any parking garage providing spaces available to the general public. 6. For parking garages containing over 200 spaces, internal signs above each parking space must indicate availability of that space. L. Specialized Vehicle Parking 1. Specialized vehicles must not be parked in any required setback area. 2. Specialized vehicles such as earth-moving equipment, tractors or other heavy construction vehicles, may only be stored during construction under an active building permit or land disturbance permit, except in the IX- District. 3. Other specialized vehicles such as recreational vehicles, campers, buses (including school buses), trailers, motor coaches, boats and boat trailers, may be parked or stored in all residential districts under the following conditions: a. The vehicles is not used as living quarters. b. The location of the parking or storage area is in the buildable area of the lot and not in front of the principal structure. c. Specialized vehicles must be screened from view of adjoining properties and rights-of-way with a minimum 6-foot tall fence or wall meeting the standards of Sec. 8.3.9.
(Ord. No. 2023-12-24, § I(Att. A), 12-5-2023)
Ask a question about Sandy Springs law
Corpus searches the Sandy Springs sections it holds and shows the ones that match, with their citations. Free, no sign-in.