Sec. 8.5.4. - Outdoor Lighting Design

A. Design and Installation 1. The maximum light level of any light fixture cannot exceed 0.5 footcandle measured at the property line of any Urban or Protected Neighborhood zoning district and 2.0 footcandles measured at the right-of-way line of a street. 2. Lighting must not be oriented onto adjacent properties, streets or sidewalks. 3. Service connections for all freestanding lighting fixtures must be installed underground. B. Parking and Pedestrian Areas 1. Light fixtures within vehicle parking areas may be no higher than 30 feet. 2. Light fixtures within pedestrian areas may be no higher than 15 feet. [image omitted; see the official code] 3. Light fixtures located within 50 feet of the property line of a Protected Neighborhood may be no higher than 15 feet. When pedestrian lighting is required along a street, light fixtures may be no higher than 15 feet. 4. Light fixtures within 25 feet of a street right-of-way (not including an alley) must be forward throw fixtures. 5. All light fixtures must be full cutoff, except as listed in paragraph F. below. [image omitted; see the official code] C. Non-cutoff (unshielded) fixtures may be used when the maximum initial lumens generated by each fixture is less than 9,500 lumens. These fixtures generally feature globes or vertical glass planes and must be coated with an internal white frosting to diffuse light. [image omitted; see the official code] D. Floodlights Floodlight fixtures must either be aimed down at least 45 degrees from vertical, or the front of the fixture shielded so that no portion of the light bulb extends below the bottom edge of the shield. [image omitted; see the official code] E. Vehicular Canopies Lighting under vehicular canopies must be less than 24 footcandles and be designed to prevent glare off-site. Acceptable lighting designs include the following: 1. Recessed Recessed fixture incorporating a lens cover that is either recessed or flush with the bottom surface of the canopy; [image omitted; see the official code] 2. Shielded Light fixture incorporating shields or is shielded by the edge of the canopy itself, so that light is restrained to 5 degrees or more below the horizontal plane; [image omitted; see the official code] 3. Surface Mounted Surface mounted fixture incorporating a flat glass that provides a cutoff design or shielded light distribution; or [image omitted; see the official code] 4. Indirect Indirect lighting where light is beamed upward and then reflected down from the underside of the canopy, provided the fixture is shielded so that direct illumination is focused exclusively on the underside of the canopy. [image omitted; see the official code] F. Building Lighting 1. Lighting fixtures must be selected, located, aimed and shielded so that direct illumination is focused exclusively on the building façade, plantings and other intended site features and away from adjoining properties and the street right-of-way. 2. All wall pack fixtures must be full cutoff fixtures. [image omitted; see the official code] 3. Only lighting used to accent architectural features, landscape or art may be directed upward, provided that the fixture is located, aimed or shielded to minimize light spill into the night sky.

(Ord. No. 2023-12-24, § I(Att. A), 12-5-2023)

Ask a question about Sandy Springs law

Corpus searches the Sandy Springs sections it holds and shows the ones that match, with their citations. Free, no sign-in.