§ 9.4.3 — Retaining Walls
Code of Ordinances of the City of Sandy Springs, Georgia (Codified through Ordinance No. 2026-03-006, enacted March 17, 2026 (Supp. No. 24)) · Sandy Springs Development Code § 9.4.3
Corpus is an independent public-information project, not the official City of Sandy Springs website. Stable reference: corpuslaw.us/code/70634d2f-d23f-4b16-bd65-719ffd7e7938
Sec. 9.4.3. - Retaining Walls
Where retaining walls are necessary, they are limited as follows: A. Design 1. Height a. Measurement Total retaining wall height is considered to be: i. Structure Height (Building Code)—The vertical distance measured from the bottom of the footing to the top of the wall at the same section. ii. Exposed Height (Zoning Code)—The vertical distance measured from finished grade at the bottom of the front (exposed) side of the wall to the top of the wall at the same section. b. Maximum Height i. Retaining Walls Up to 6 feet in exposed wall height as a single wall in RE-, RD-, and RU zoning districts. Up to 8 feet in exposed wall height as a single wall in all other districts, except when abutting a Protected Neighborhood. ii. Tiering Walls Over the maximum exposed wall heights for a single wall in each district, requires tiering. Each wall tier must adhere to the maximum wall height as described above. See Sec. 9.4.3 A.2.a below for horizontal spacing requirements. iii. Interior Facing a) Retaining walls that are entirely interior facing are permitted up to 12 feet in exposed height. This includes Wing Walls (retaining wall extensions from the building foundation walls that allow daylighting of a basement and/or egress from a basement) that are inward facing and finished with a permitted material finish. 1) Setbacks If they are to encroach into building setbacks and are entirely inward facing the walls must be a maximum of 6 feet in exposed wall height and meet the retaining wall setback requirements found in Sec. 9.4.3 C. below. 2) Length Maximum length of any wall exceeding the normal maximum retaining wall height is 36 feet (based on the maximum 3:1 allowable grading slope). Any length of wall past 36 feet must meet the requirements of a retaining wall as outlined above. b) The Director may permit retaining walls that are entirely interior facing on campuses with civic or institutional uses to have up to 24 feet in exposed height. This includes wing walls that are finished with a permitted material finish. iv. Exterior Facing Retaining walls that are exterior facing and at least 100 feet from a street lot line and 75 feet from a common lot line are permitted up to 12 feet in exposed height. This includes wing walls that are finished with a permitted material finish. c. Elevation Marks Wall height elevations marks must be demonstrated on the grading plan through callouts at various locations along the retaining wall using the following or similar: TW-Top of Wall; BW-Bottom of Wall (at Grade); BF-Bottom of Footing. d. Fences or Walls on Top of Retaining Walls Fences or walls extending on top of retaining walls are subject to the requirements of Sec. 8.3.10. Within Setbacks at Any Point For retaining walls and tiered wall systems which begin in or enter into a building setback, the combined height of the retaining wall and an extension fence or wall must not exceed the maximum height of retaining walls, per Sec. 9.4.3 D. and Sec. 9.4.3 E, unless required in order to comply with applicable life safety regulations. In a tiered retaining wall system, an extension fence or wall must only be located on the highest tier. 2. Spacing a. Distance Retaining walls must be separated horizontally by at least 4 feet from other retaining walls (measured from the back of the lower wall to the front of the upper wall). This horizontal separation area must be graded to capture stormwater and not sloped such that stormwater will run off. The stormwater design must be included with the retaining wall permit plans. b. Design Each tier between retaining walls, and any retaining wall within a building setback, must be vegetated and maintained with a mix of native, evergreen, and deciduous shrubs, 1 shrub every 4 linear feet to be approved by the City Arborist. The Director may waive this landscaping standard for retaining walls that slope back (are inward facing) and contain natural planting. 3. Materials a. Material and Finish All retaining walls must be finished with stucco, brick, or stone. No beveled modular block, plain unfinished concrete masonry units, or other similar materials are allowed. Retaining walls may utilize alternative facing elements such as evergreen vegetation as approved by the Director. The wall must be located only in side or rear yards and be planted with native, non-invasive evergreen planting material. The plant growth must be at a minimum 50% of the wall's face prior to closeout of the permit and maintained throughout all seasons. Retaining walls which meet the description of Garden Walls below in Sec. 9.4.3 B.3. may also use cross ties, landscape timbers, or similar as a wall, material finish. B. Permits and Other Requirements 1. All Retaining walls, whether in commercial or residential settings, regardless of height: Require a retaining wall permit and a professional engineer's certification of the design of the wall if they support a surcharge. Surcharge is defined as any vertical load imposed on the retained soil that may impose a lateral force in addition to the lateral earth pressure of the retained soil. Examples of surcharges include: a. Sloping retaining soil; b. Structure footings supported by the retained soil; c. Adjacent vehicle loads supported by the retained soil; d. Tiered retaining wall systems. 2. Permit Required All retaining walls over 4 feet in structure height require a retaining wall permit and walls 6 feet and over require a professional engineer's certification of the design of the wall. 3. No Permit Required All other retaining walls 4 feet or less in structure height do not require a permit but do require an indemnification letter. This includes retaining walls otherwise known as "Garden Walls" which for the purposes of this Code have a maximum exposed height of 3 feet, while also not exceeding 4 feet of structure height. 4. Global Stability During the permit review process, the global stability of any series of tiered retaining walls will be reviewed. A safety factor of at least 1.5 is required. 5. Impact Where a retaining wall or wing wall might impact (either visually or structurally) an existing structure, adjacent property, street, buffer, utility, or other similar significant interest, the Director and/or Building Official may require plans, details, cross-sections, and professional engineer calculations beyond those cited in this Section. C. Setback Encroachment In order to protect trees and vegetation on sites and the character of the neighborhood, the following setback standards apply: 1. Side Setbacks In the side building setbacks: a. In all RE- Districts, retaining walls may encroach up to 10 feet into required side building setbacks. b. In all RD- Districts, retaining walls may encroach up to half the depth of the required side building setbacks. c. In all RU- Districts, no encroachment for retaining walls is allowed into the required side building setbacks. d. All other districts, retaining walls may encroach into the side setbacks so long as they are at least 3 feet from the vertical plane of any lot line. 2. Rear Setbacks In the rear building setbacks: a. In all RE- districts, no retaining walls are allowed within 20 feet of the rear lot line. b. In the RD-27, RD-18, and RD-15 districts, no retaining walls are allowed within 15 feet of the rear lot line. c. In the RD-12, RD-9, RD-7.5, and RU- districts, no retaining walls are allowed within 10 feet of the rear lot line. d. All other districts, retaining walls may encroach into the rear setbacks so long as they are at least 3 feet from the vertical plane of any lot line. D. Maintenance and Replacement Existing legally permitted and constructed retaining walls may be maintained and repaired, provided the maintenance and repair is structurally sound and does not result in an increase in the height of the wall above grade.
(Ord. No. 2023-12-24, § I(Att. A), 12-5-2023; Ord. No. 2024-06-10, § I, 6-18-2024; Ord. No. 2025-09-22, § I, 9-16-2025)
Ask a question about Sandy Springs law
Corpus searches the Sandy Springs sections it holds and shows the ones that match, with their citations. Free, no sign-in.
