Sec. 9.5.4. - Flood Damage Reduction
A. General Standards In all areas of special flood hazard and areas of future-conditions flood hazard the following provisions apply: 1. New construction and substantial improvements of structures (residential or nonresidential), including manufactured homes, will not be allowed within the limits of the future-conditions floodplain, unless all requirements of Sec. 9.5.3 have been met. 2. If, due to site conditions, an existing single-family residential structure cannot comply with Sec. 9.5.4 A.1, the structure may be elevated in accordance with either Sec. 9.5.4 B.1.C or Sec. 9.5.4 B.1.d: provided however, Sec. 9.5.4 A.5 will apply to all elevated structures regardless of whether Sec. 9.5.4 B.1.c or Sec. 9.5.4 B.1.d applies. 3. New construction and substantial improvements must be anchored to prevent flotation, collapse, and lateral movement of the structure. 4. New construction and substantial improvements must be constructed with materials and utility equipment resistant to flood damage. 5. New construction and substantial improvements must be constructed by methods and practices that minimize flood damage. 6. Elevated building. All new construction and substantial improvements that include any fully enclosed area located below the lowest floor formed by foundation and other exterior walls are designed so as to be an unfinished or flood-resistant enclosure. The enclosure is designed to equalize hydrostatic flood forces on exterior walls by allowing for the automatic entry and exit of floodwater. a. Designs for complying with this requirement must either be certified by a licensed professional engineer or architect to meet or exceed the following minimum criteria: i. Provide a minimum of 2 openings having a total net area of not less than 1 square inch for every square foot of enclosed area subject to flooding; ii. The bottom of all openings are no higher than 1 foot above grade; and iii. Openings may be equipped with screens, louvers, valves or other coverings or devices provided they permit the automatic flow of floodwater in both directions. b. So as not to violate the lowest floor criteria of this Division, the unfinished or flood-resistant enclosure must only be used for parking of vehicles, limited storage of maintenance equipment used in connection with the premises, or entry to the elevated area; and c. The interior portion of such enclosed area must not be finished or partitioned into separate rooms. 7. All heating and air conditioning equipment and components (including ductwork), all electrical, ventilation, plumbing, and other service facilities are designed and/or located 3 feet above the base flood elevation or 1 foot above the future-conditions flood elevation, whichever is higher, so as to prevent water from entering or accumulating within the components during conditions of flooding; 8. Manufactured homes are anchored to prevent flotation, collapse, and lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This standard is in addition to and consistent with applicable state requirements for resisting wind forces; 9. All proposed development must include adequate drainage and stormwater management facilities per the requirements of the City to reduce exposure to flood hazards; 10. New and replacement water supply systems are designed to minimize or eliminate infiltration of floodwaters into the system; 11. New and replacement sanitary sewage systems are designed to minimize or eliminate infiltration of floodwaters into the systems and discharges from the systems into floodwaters; 12. On-site waste disposal systems are located and constructed to avoid impairment to, or contamination from such systems during flooding; 13. Other public utilities such as gas and electric systems must be located and constructed to avoid impairment to them, or public safety hazards from them during flooding; 14. Any alteration, repair, reconstruction or improvement to a structure which is not compliant with the provisions of this Division is undertaken only if the nonconformity is not furthered, extended or replaced; 15. If the proposed development is located in multiple flood zones or multiple base flood elevations cross the proposed site, the higher or more restrictive base flood elevation or future-condition elevation and development standards must take precedence; 16. When only a portion of a proposed structure is located within a flood zone or the future conditions floodplain, the entire structure must meet the requirements of this Division; and 17. Subdivision proposals and other proposed new development, including manufactured home parks or subdivisions, must be reasonably safe from flooding: a. All such proposals must be consistent with the need to minimize flood damage within the flood-prone area; b. All public utilities and facilities, such as sewer, gas, electrical, and water systems must be located and constructed to minimize or eliminate flood damage; and c. Adequate drainage must be provided to reduce exposure to flood hazards. B. Building Standards for Structures and Buildings within the Future-Conditions Floodplain 1. Residential Buildings a. New Construction New construction of principal residential structures must not be allowed within the limits of the future-conditions floodplain. b. Substantial Improvements Substantial improvements of any principal residential structure must have the lowest floor, including basement, elevated no lower than 3 feet above the base flood elevation or 1 foot above the future-conditions flood elevation, whichever is highest. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to automatically equalize the hydrostatic flood forces on exterior walls must be provided in accordance with the standards of Sec. 9.5.4 A. c. Elevation of Existing Structures Via Jacking on Existing Foundation An existing structure that has been substantially damaged or is proposed for substantial improvement may be elevated by jacking, intact, on an existing foundation, provided the criteria of Sec. 9.5.4 A.5 are met in addition to the following criteria: i. No elevated structure can exceed the original geometric footprint area or horizontally expand living space into or over the future conditions floodplain; ii. Foundations must contain a minimum of 2 openings having a total net area of not less than 1 square inch for every square foot of enclosed area subject to flooding as provided in 44 C.F.R. § 60.3; iii. The bottom of all openings must be no higher than 1 foot above grade; and iv. Openings may be equipped with screens, louvers or other coverings provided they permit the flow of floodwater in both directions. d. Elevation of Existing Structures Via Demolition and Rebuilding on an Equivalent Footprint Area An existing structure that has been substantially damaged or is proposed for substantial improvement may be demolished and relocated on the lot such that the passage of water is facilitated or the floodplain is otherwise enhanced or protected, provided the criteria of Sec. 9.5.4 A.5 are met in addition to the following criteria: i. No elevated structure can exceed the original footprint area or increase the net encroachment into or over the floodplain; and ii. Foundations must be designed to resist anticipated hydrodynamic loads, potential for debris impact, and scour pursuant to FEMA Technical Bulletin I (August 2008). Foundations must be designed with the following criteria: a. The total area of the walls below the base flood elevation exposed to flood waters must be at least 50% open. Wall openings must be distributed along all walls exposed to flood waters; b. The bottoms of all wall openings must be at grade; c. Garage doors not allowing the natural flow of floodwaters when closed must not be considered wall openings; and d. Openings may be equipped with grilles, louvers, or bars provided they allow the natural flow of floodwater in both directions. 2. Nonresidential Buildings a. New Construction New construction of principal nonresidential structures must not be allowed within the limits of the future-conditions floodplain unless all of the requirements of Sec. 9.5.3 are met. If all of the requirements of Sec. 9.5.3 have been met, all new construction must have the lowest floor, including basement, elevated no lower than 1 foot above the base flood elevation or at least as high as the future-conditions flood elevation, whichever is higher. Should solid foundation perimeter walls be used to elevate the structure, openings sufficient to automatically equalize the hydrostatic flood forces on exterior walls must be provided in accordance with the standards of Sec. 9.5.4 A. New construction that has met all of the requirements of Sec. 9.5.3 may be floodproofed in lieu of elevation. The structure, together with attendant utility and sanitary facilities, must be designed to be watertight to 1 foot above the base flood elevation, or at least as high as the future-conditions flood elevation, whichever is higher, with walls substantially impermeable to the passage of water and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A licensed professional engineer or architect must certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above, and must provide such certification to the Director using the FEMA floodproofing certificate along with the design and operation/maintenance plan. b. Substantial Improvements Substantial improvements of any principal nonresidential structure located in A1-30, AE, or AH zones may be authorized by the Director to be elevated or floodproofed. Substantial improvements must have the lowest floor, including basement, elevated no lower than 1 foot above the base flood elevation or at least as high as the future-conditions flood elevation, whichever is higher. Should solid foundation perimeter walls be used to elevate the structure, openings sufficient to automatically equalize the hydrostatic flood forces on exterior walls must be provided in accordance with the standards of Sec. 9.5.4 A. Substantial improvements may be floodproofed in lieu of elevation. The structure, together with attendant utility and sanitary facilities, must be designed to be watertight to 1 foot above the base flood elevation, or at least as high as the future-conditions flood elevation, whichever is highest, with walls substantially impermeable to the passage of water, and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A licensed professional engineer or architect must certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above, and must provide such certification to the Director using the FEMA floodproofing certificate along with the design and operation/maintenance plan. c. Accessory Structures and Facilities Accessory structures and facilities (i.e., barns, sheds, gazebos, detached garages, recreational facilities and other similar non-habitable structures and facilities) which meet the requirements of Sec. 9.5.3 and are permitted to be located within the limits of the future-conditions floodplain must be constructed of flood-resistant materials and designed to provide adequate flood openings in accordance with Sec. 9.5.4 A. and be anchored to prevent flotation, collapse, and lateral movement of the structure. d. Recreational Vehicles All recreational vehicles placed on sites must either: i. Be on the site for fewer than 180 consecutive days and be fully licensed and ready for highway use (a recreational vehicle is ready for highway use if it is licensed, on its wheels or jacking system, attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached structures or additions); or ii. Meet all the requirements for residential buildings—Substantial improvements set forth in Sec. 9.5.4 B.1.b, including the anchoring and elevation requirements. e. Manufactured Homes i. New manufactured homes must not be allowed to be placed within the limits of the future-conditions floodplain unless all of the requirements of Sec. 9.5.3 have been met, all new construction and substantial improvements must have the lowest floor, including basement, elevated no lower than 3 feet above the base flood elevation or 1 foot above the future-conditions flood elevation, whichever is higher. Should solid foundation perimeter walls be used to elevate the structure, openings sufficient to automatically equalize the hydrostatic flood forces on exterior walls must be provided in accordance with the standards of Sec. 9.5.4 A. ii. Manufactured homes placed and/or substantially improved in an existing manufactured home park or subdivision are elevated so that either: (a) The lowest floor of the manufactured home is elevated no lower than 3 feet above the level of the base flood elevation, or 1 foot above the future-conditions flood elevation, whichever is higher; or (b) The manufactured home chassis is elevated and supported by reinforced piers (or other foundation elements of at least an equivalent strength) of no less than 36 inches in height above grade. iii. All manufactured homes must be securely anchored to an adequately anchored foundation system to resist flotation, collapse and lateral movement in accordance with the standards of Sec. 9.5.4 A.7. C. Building Standards for Structures and Buildings Authorized Adjacent to the Future-Conditions Floodplain 1. Residential Buildings For new construction of and substantial improvement to any principal residential building or manufactured home, the elevation of the lowest floor, including basement and access to the building, is at least 3 feet above the level of the highest base flood (100-year) elevation adjacent to the building or at least 1 foot above the future-conditions flood elevation, whichever is higher. Should solid foundation perimeter walls be used to elevate the structure, openings sufficient to automatically equalize the hydrostatic flood forces on exterior walls must be provided in accordance with the standards of Sec. 9.5.4. 2. Nonresidential Buildings For new construction of and substantial improvement to any principal nonresidential building, the elevation of the lowest floor, including basement and access to the building, is at least 3 feet above the level of the highest base flood elevation adjacent to the building or at least 1 foot above the future-conditions flood elevation, whichever is higher. Should solid foundation perimeter walls be used to elevate the structure, openings sufficient to automatically equalize the hydrostatic flood forces on exterior walls must be provided in accordance with the standards of Sec. 9.5.4. Nonresidential buildings may be floodproofed in lieu of elevation. D. Building Standards for Residential Single-Lot Development on Streams without Established Base Flood Elevations and/or Floodway (A zones) For a residential single-lot development not part of a subdivision that has areas of special flood hazard, where streams exist but no base flood data have been provided (A zones), the Director will review and reasonably utilize any available scientific or historic flood elevation, data, base flood elevation floodway data or future-conditions flood elevation data available from a federal, state, or other source in order to administer the provisions and standards of this Division. If data are not available from any of these sources, the following provisions will apply: 1. No encroachments, including structures or fill material, must be located within an area equal to twice the width of the stream or fifty feet from the top of the bank of the stream, whichever is greater. 2. In special flood hazard areas without base flood or future-conditions flood elevation data, new construction and substantial improvements must have the lowest floor of the lowest enclosed area (including basement) elevated no less than 3 feet above the highest adjacent grade at the building site. Flood openings sufficient to facilitate automatic equalization of hydrostatic flood forces must be provided for flood-prone enclosures in accordance with Sec. 9.5.4 A.5.a. E. Building Standards for Areas of Shallow Flooding (AO zones) Areas of special flood hazard may include designated AO shallow flooding areas. These areas have base flood depths of 1 foot to 3 feet above ground, with no clearly defined channel. In these areas the following provisions apply: 1. All new construction and substantial improvements of residential and nonresidential structures must have the lowest floor, including basement, elevated to no lower than 1 foot above the flood depth number specified on the flood insurance rate map (FIRM), above the highest adjacent grade. If no flood depth number is specified, the lowest floor, including basement, is elevated at least 3 feet above the highest adjacent grade. Flood openings sufficient to facilitate automatic equalization of hydrostatic flood forces must be provided in accordance with the standards of Sec. 9.5.4 A.5.a; 2. New construction and substantial improvement of a nonresidential structure may be floodproofed in lieu of elevation. The structure, together with attendant utility and sanitary facilities, must be designed to be watertight to the specified FIRM flood level plus 1 foot above the highest adjacent grade, with walls substantially impermeable to the passage of water, and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A licensed professional engineer or architect must certify that the design and methods of construction are in accordance with accepted standards of practice, and must provide such certification to the City using the FEMA floodproofing certificate along with the design and operation/maintenance plan; and 3. Drainage paths must be provided to guide floodwater around and away from any proposed structure. F. Standards for Subdivisions of Land and Other Development 1. All subdivision proposals must identify the areas of special flood hazard and areas of future-conditions flood hazard therein and provide base flood elevation data and future-conditions flood elevation data; 2. All residential lots in a subdivision proposal must have sufficient buildable area outside of the future-conditions floodplain such that encroachments into the future-conditions floodplain for residential structures will not be required; 3. All subdivision plans will provide the elevations of proposed structures in accordance with Sec. 9.5.2 C. G. Standards for Utilities 1. All new and replacement water supply and sanitary sewerage systems are designed to minimize or eliminate: a. Infiltration of floodwaters into the systems; and b. Discharges from the systems into floodwaters. 2. On-site waste disposal systems are located outside the floodplain to avoid impairment to them, or contamination from them during flooding.
(Ord. No. 2023-12-24, § I(Att. A), 12-5-2023)
Ask a question about Sandy Springs law
Corpus searches the Sandy Springs sections it holds and shows the ones that match, with their citations. Free, no sign-in.