§ 3-2020 — Requirements for approved oil-fueled wick-type heaters

Code of Ordinances of the City of Savannah, Georgia (Division II) (enCodePlus online edition as published 2026-11-20) · Savannah Code of Ordinances, pt. 3, ch. 2., art. A, § 3-2020

Corpus is an independent public-information project, not the official City of Savannah website. Stable reference: corpuslaw.us/code/314bd279-dc56-493d-93d0-c9e54feafb58

Sec. 3-2020. - Requirements for approved oil-fueled wick-type heaters.

Approved oil-fueled wick-type heaters shall adhere to the following requirements: (a) Approved oil-fueled wick-type heaters shall have labeling affixed thereto that cautions and informs concerning: (1) Provision of an adequate source of ventilation when the heater is in operation; (2) Use of only suitable fuel for the heater; (3) Proper manner of fueling; (4) Proper placement and handling of the heater when in operation; (5) Proper procedures for lighting, flame regulation and extinguishing the heater; and (6) A statement, "This heater must not be operated while unattended." (b) Approved oil-fueled wick-type heaters shall be packaged with instructions concerning proper maintenance and operation. (c) Approved oil-fueled wick-type heaters shall be constructed with a low center of gravity and minimum tipping angle of 30 degrees from the vertical with an empty reservoir. (d) Approved oil-fueled wick-type heaters shall have an automatic shutoff device or other inherent design feature which eliminates fire hazards in the event of tipover and conforms with the standards set forth in National Fire Protection Association (NFPA) No. 31. (e) Approved oil-fueled wick-type heaters shall not produce carbon monoxide at rates which create a hazard when operated as intended and instructed. (f) Approved oil-fueled wick-type heaters shall be listed. "Listed" means any oil-fueled wick-type heater which has been evaluated with respect to reasonable foreseeable hazards to life and property by anyone of the following nationally recognized testing agencies: Underwriters' Laboratories, Inc., Canadian Standards Association or Factory Mutual System, and is shown to be reasonably safe for its specific purpose and shown in a list published by such agency and bears the mark, name or symbol of such agency as indication that it has been so authorized. Such evaluation shall include but not be limited to evaluation of the requirements listed above. Similar evaluations by a nationally recognized testing agency, other than the above mentioned, which are approved by the city manager may be listed as well. (g) Approved oil-fueled wick-type heaters shall have affixed to the front, top or area adjacent to the fueling point of the heater, in red lettering, not less than one-half inch in height: "WARNING - DO NOT USE GASOLINE." (h) Any listed oil-fueled wick-type heater shall be approved if it satisfies the requirements herein set forth.

(Code 1977, § 3-2019)

Ask a question about Savannah law

Corpus searches the Savannah sections it holds and shows the ones that match, with their citations. Free, no sign-in.