Sec. 4-7601. - Fueling operations.

(a) No person shall fuel or defuel an aircraft until said person is properly trained and has been officially certified as being qualified to perform such fueling operations on said aircraft by a certified fuel handler. Training shall be performed in accordance with FAR part 139 standards. Training records shall be maintained on each person. Records shall indicate initial training and all recurrent training, which shall be conducted on a scheduled basis. A fuel training report shall be submitted to the airport director on a monthly basis. All records shall be subject to inspection by the airport commission. (b) No aircraft shall be refueled, defueled, or oil serviced while aircraft engines are running or while such aircraft is in a hangar or a congested or enclosed space. (c) No aircraft shall be fueled or defueled while passengers are on board the aircraft unless a passenger loading ramp is in place at the cabin door of the aircraft, the aircraft door is in open position, and a cabin attendant is present at or near the cabin door. (d) Prior to fueling or defueling an aircraft, the aircraft and the fuel-dispensing equipment, and all hoses, funnels and appurtenances used in connection therewith, shall be grounded to a point or points of zero electrical potential in accordance with FAA and NFPA codes and recommended practices to prevent the possibility of static ignition of volatile liquids. (e) All aircraft refueling vehicles and equipment, to include but not limited to fueling pumps, meters, hoses, nozzles, funnels, grounding devices, and appurtenances, used during fueling operations shall be maintained in a safe operating condition and in good repair at all times. On finding any refueling vehicles or equipment to be defective, in a state of disrepair or malfunction, the use of said refueling vehicles or equipment constitutes an undue fire or safety hazard or is in violation of any federal, state or airport regulation. The owner/operator shall discontinue the use of such vehicles and/or equipment until repairs, replacements or changes are made or may be necessary to render the same safe for continued use. Any malfunctions or irregularity detected in or within the aircraft being serviced shall be brought to the attention of the aircraft owner or operator immediately. (f) During refueling or defueling operations: (1) Refueling vehicles shall be so placed as to be readily removable in the event of fire so as to permit direct driving away from the loading or fueling position. (2) Not more than one refueler shall be positioned to refuel each wing of an aircraft, and not more than two refuelers shall be positioned to serve the same aircraft. (3) Additional refuelers shall not be parked or positioned within 100 feet from the aircraft served when high-capacity aircraft are refueled, and then only in areas approved by the airport director. (4) No person shall operate any radio transmitter or receiver or switch electrical appliances off or on in an aircraft. (5) No person shall use any material or equipment which is likely to cause a spark or ignition. (g) No person shall perform or allow performance of any refueling operations when an electrical storm is within three miles of the airport. (h) No airborne radar equipment shall be operated or ground tested on any area wherein the directional beam of high-intensity radar is within 300 feet or low-intensity radar (less than 50 kw output) is within 100 feet of another aircraft, an aircraft refueling operation, an aircraft refueling truck, or aircraft fuel or flammable liquid storage facility. (i) All refueling vehicles, equipment, and airport fuel storage facilities shall be placarded, marked and/or color coded in accordance with NFPA publication 407 and applicable FAA advisory circulars. (j) A qualified operator shall be in attendance at all times while fuel delivery vehicles dispense fuel into or load fuel from any airport fuel storage facility. The operator shall remain within the immediate vicinity and in direct view of all operating controls and equipment. The operator shall not leave the discharge end of any hose or hoses unattended at any time while the transfer of fuel is in progress. (k) No person shall engage in any fueling or defueling operation at the airport without first making readily available at the point of fueling the correct type and number of fire extinguishing equipment as required by the National Fire Codes. (l) Drivers of refueling vehicles shall not back said vehicle unless a signalman is present to guide the driver. The driver must remain in the vehicle cab and shall not stand on the running board or fender while backing the vehicle. (m) The airport commission assumes no liability or responsibility for tenant violations of FAA fueling requirements and procedures. The tenant shall be solely responsible for any violation incident to or in connection with the tenant's fueling facilities, equipment, operations, and training. The tenant shall reimburse the airport commission for any fines or legal or court costs incurred by the airport commission for such violations. (n) Fuel spills. (1) Crews engaged in the fueling, defueling, and oil service of aircraft; the filling of dispensing equipment; or the dumping into storage of aviation fuels shall exercise extreme caution to prevent spills. When fuel or oil spills occur, servicing shall cease, the fire department shall be notified, and all available (non-water-type) fire extinguishers shall be brought to the scene. Spills shall be picked up by the agency responsible for the spill using materials manufactured specifically for the removal of fuel and oil spills. In the event that any agency fails or refuses to comply with such cleaning, the airport commission may clean up the spillage or contract with an outside agency specializing in removal of fuel spills to clean up the spillage at the responsible party's expense. The airport commission shall charge the agency for all labor, materials and an administration fee for all work done. Materials used to pick up fuel and oil spills shall be placed in approved containers and disposed of in accordance with federal, state and local ordinances. (2) No person shall start the engine of any aircraft when fuel has spilled on the ground under said aircraft. (3) Drip pans shall be placed under aircraft engines and kept clean at all times.

(Code 1977, § 4-7601)

Ask a question about Savannah law

Corpus searches the Savannah sections it holds and shows the ones that match, with their citations. Free, no sign-in.