Sec. 4-7705. - Minimum standards for corporate hangars.
In addition to the requirements of these regulations, the following additional standards apply when constructing, maintaining and/or altering corporate hangars: (a) Structure generally. Hangar structure shall consist of a minimum of 4,800 square feet. Hangar floors shall be paved throughout. Proper floor drainage and grounding joints shall be provided in accordance with the National Fire Codes. If asphaltic material is used, a sealer shall be applied to prevent erosion caused by petroleum products. (b) Storm and sanitary drainage. Effluent entering storm and sanitary drainage systems must be free of all petroleum products. When petroleum spills are expected, the necessary filter system shall be installed in accordance with existing regulations. (c) Outside storage. Outside storage shall be prohibited. Accumulations of trash, equipment, and vehicles shall not be allowed. (d) The tenant shall pay all utility costs and for that portion of the paving between the tenant's hangar and public taxiway. If asphaltic material is used for this paved connection, it shall also be treated with a sealer to prevent petroleum erosion. (e) Ownership of all improvements shall revert to the airport commission at the end of the original 20-year lease. (f) The tenant shall not be authorized to perform fuel or oil sales or perform repairs or other services to aircraft, vehicles or equipment except to aircraft, vehicles or equipment belonging to its tenants under a sublease approved by the airport director. (g) A fuel facility may be authorized upon written request to the airport commission providing tenant shall pay to the airport commission a fuel flowage fee per gallon on all fuel and oil delivered to tenant's facility. Payments shall be supported by duplicate invoices from the wholesale vendor upon delivery. The airport commission reserves the right in its own discretion to increase or decrease the amount of such license, privilege charge, or tax but agrees that, in the event of any increase or decrease thereof, such increase or decrease shall be uniform to the tenant and to all such tenants, licensees and lessees using the facilities of the airport. (h) The tenant shall execute a hold-harmless agreement with the airport commission. (i) The tenant shall assure that all employed personnel are made aware of current airport rules and regulations and that the tenant's employees and guests observe the same. (j) Buildings shall be of metal or masonry construction, properly fireproofed, have properly designed doors at both ends, and must be stressed for hurricane area winds of 120 miles per hour. Floor and ramps shall be of concrete or properly compacted subgrade of sufficient design load strength to sustain all types of aircraft which are planned to use the facility. (k) An area of 1,200 feet of office space, restrooms, and lounge, which may be an adjunct to other buildings, must also be fireproofed and of steel or masonry SIA construction, properly stressed for hurricane area winds, and comply with NFPA articles 409 and 220. (l) Sufficient outside hose connections for washing of aircraft and other purposes, such as washing ramps, watering of shrubbery, etc., must be installed. Should a new building be constructed over 300 feet from an existing fire hydrant, a new hydrant shall be provided. (m) No signage shall be placed on hangars or leased property without the prior written approval of the airport director.
(Code 1977, § 4-7705; Ord. of 4-14-1994, § 2)
Ask a question about Savannah law
Corpus searches the Savannah sections it holds and shows the ones that match, with their citations. Free, no sign-in.