§ 4-9005 — Specifications for ratproofing
Code of Ordinances of the City of Savannah, Georgia (Division II) (enCodePlus online edition as published 2026-11-20) · Savannah Code of Ordinances, pt. 4, ch. 9., § 4-9005
Corpus is an independent public-information project, not the official City of Savannah website. Stable reference: corpuslaw.us/code/b2807749-3974-4d95-a84a-c4306e2b660a
Sec. 4-9005. - Specifications for ratproofing.
To be ratproofed, a building must comply with at least the following specifications: (a) Particular openings. (1) Exterior doors, including sliding and folding types, shall be constructed so that the space between the door when closed and the threshold and jambs shall not exceed three-eighths inch. The space between sections of exterior folding and sliding doors, when closed, shall not exceed three-eighths inch. Exterior doors of a building which remain open when not being used for passage shall be equipped with screen doors conforming to the specifications of exterior doors and having an automatic closing device in good operating condition. (2) Floor drains which will admit a cylinder larger than one-half inch in diameter shall be covered at their origin inside the building with a perforated metal or iron cover that is properly secured. No perforation in the cover shall be large enough to admit a cylinder more than one-half inch in diameter. (3) Mail slots less than 48 inches from the threshold shall have a properly operating hinged metal cover that opens outward. (4) Roof ventilators, chimneys, pipe vents and downspouts accessible to rats shall be covered by grills, hardware cloth caps, perforated or expanded metal or other material acceptable to the city. Inverted baskets or wire cages may be used on chimneys and downspouts. No perforation in the cover shall be large enough to admit a cylinder more than one-half inch in diameter. (b) Other openings. All other openings in exterior surfaces which will admit a cylinder larger than one-half inch in diameter shall be closed with a material impervious to rat gnawing if they are within 48 inches of the ground level immediately below such openings or if they may be reached from the ground by rats climbing up guarded pipes, wires, cornices, stairs, roofs, trees, vines or other items, or by burrowing. In the event that business practices result in stacking or piling materials along exterior walls, ratproofing shall be extended to a height of 48 inches above the highest probable level of storing or piling.
(Code 1977, § 4-9005)
Ask a question about Savannah law
Corpus searches the Savannah sections it holds and shows the ones that match, with their citations. Free, no sign-in.