7.2.7 Design Standards
(a) Noise Level Reduction Standards Where Noise Level Reduction (NLR) requirements exist, structures shall be designed and constructed to minimize noise by achieving an outdoor to indoor peak noise level reduction (NLR) of at least 25 dB. Normal construction can be expected to provide an NLR of 20 dB thus the actual required reduction is only five (5) dB. Lowering the NLR can be achieved through incorporation, into the design and construction of all proposed uses, of appropriate sound insulation materials and methods for improving acoustic insulation performance. A qualified professional satisfactory to the City Manager or his or her designee shall certify that the design standards, construction standards and/or materials used to construct the structure will achieve the required noise level reductions prior to the issuance of a building permit. The building plan shall meet the following requirements in addition to all other applicable requirements of the building code: (i) All exterior doors shall be either: (1) Solid-core or metal-clad construction; (2) Separately equipped with wood or metal storm door; or (3) Multiple-glazed. (ii) Multiple-glazed windows shall be provided for all habitable space. (iii) Through-the-wall/door mailboxes, venting skylights, or other direct openings from the interior to the exterior of the building shall be prohibited. (iv) Mechanical ventilation shall be provided of a type and design to provide adequate environmental comfort with all doors and windows closed during all seasons. Window and through-the-wall ventilation units shall not be used. Commercial cooking areas are exempt from these conditions. (b) The following design standards apply within the APZ 1 and APZ II of HAAF: (i) Rooftops shall be made of non-reflective material. (ii) All outdoor lighting shall be shielded so that no direct glare from the light can be seen from above with the following exceptions: (1) Publicly approved warning lights to mark obstructions to aircraft are exempted from this regulation. (2) Up lighting for buildings is permissible provided the lighting is not directed at highly reflective surfaces such as glass. Such lighting shall be shielded to prevent light from shining into the sky and above the building. (3) Lighting for flags is permitted provided that the lights are not pointed directly down the final approach course or departure runway heading. (iii) All illuminated signs shall be shielded in such a manner that no direct glare can be seen from above.
Ask a question about Savannah law
Corpus searches the Savannah sections it holds and shows the ones that match, with their citations. Free, no sign-in.