For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8-1002 — Local code amendments

Code of Ordinances of the City of Savannah, Georgia (Division II) (enCodePlus online edition as published 2026-11-20) · Savannah Code of Ordinances, pt. 8, ch. 1., art. A, § 8-1002

Corpus is an independent public-information project, not the official City of Savannah website. Stable reference: corpuslaw.us/code/7c734bf5-1c5d-4e24-ae0c-53473749baf7

Sec. 8-1002. - Local code amendments.

(a) The following additions, deletions or revisions to the International Property Maintenance Code 2018 edition, as amended by the State of Georgia and this article constitute the minimum Standard Property Maintenance Code for the City of Savannah, Georgia. (a) Sections 102.5 and 110.4 are amended by deleting these sections in their entirety without substitution. (b) Sections 111 and 112 are amended by deleting these sections in their entirety without substitution. (c) Section 103.1 is revised to read as follows: The Code Compliance Department is hereby created and the Director of this department shall be known as the Code Official. (d) Section 107.2 paragraph 5 is amended by deleting this paragraph in its entirety. (e) Section 302.4 is amended by deleting this section in its entirety without substitution. (f) Section 304.14 is revised to read as follows: During the period from March 1 to December 31, every door, window and other outside opening required for ventilation of habitable rooms, food preparation areas, food service areas or any areas where products to be included or utilized in food for human consumption are processed, manufactured, packaged or stored shall be supplied with approved tightly fitting screens of minimum 16 mesh per inch (16 mesh per 25 mm), and every screen door used for insect control shall have a self-closing device in good working condition. Exception: Screens shall not be required where other approved means, such as air curtains or insect repellent fans, are employed. (g) Section 602.4 is revised to read as follows: Indoor occupiable workspaces shall be supplied with heat during the period from November 1 to May 1 to maintain a minimum temperature of 65° F (18° C) during the period the spaces are occupied. Exceptions: (1) Processing, storage and operation areas that require cooling or special temperature conditions. (2) Areas in which persons are primarily engaged in vigorous physical activities. (b) Pursuant to §OCGA 8-2-25 the following additions, deletions, or revisions to the International Plumbing Code 2018 edition, as amended by the State of Georgia and this article constitute the minimum Standard Plumbing Code for the City of Savannah, Georgia. (1) Section 403.1.2 of the International Plumbing Code is revised to read as follows: 403.1.2 Single-user toilet and bathing room fixtures. The plumbing fixtures located in single-user toilet and bathing rooms, including family or assisted use toilet and bathing rooms that are required by Section 1109.2.1 of the International Building Code, shall contribute toward the total number of required plumbing fixtures for a building or tenant space. Single-user toilet and bathing rooms, and family or assisted-use toilet rooms and bathing rooms shall be identified as being available for use by all persons regardless of their sex. (2) Section 403.2 of the International Plumbing Code is amended by adding exceptions (5) & (6): 403.2 Separate facilities. Where plumbing fixtures are required, separate facilities shall be provided for each sex. Exceptions: (1) Separate facilities shall not be required for dwelling units and sleeping units. (2) Separate facilities shall not be required in structures or tenant spaces with a total occupant load, including both employees and customers, of 15 or fewer. (3) Separate facilities shall not be required in mercantile occupancies in which the maximum occupant load is 100 or fewer. (4) Separate facilities shall not be required in business occupancies in which the maximum occupant load is 25 or fewer. (5) Separate facilities shall not be required to be designated by sex where single-user toilet rooms are provided in accordance with Section 403.1.2. (6) Separate facilities shall not be required where rooms having both water closets and lavatory fixtures are designed for use by both sexes and privacy for water closets is provided in accordance with Section 405.3.4. Urinals shall be located in an area visually separated from the remainder of the facility or each urinal that is provided shall be located in a stall. (3) Section 405.3.4.1 is added to the 2018 International Plumbing Code: 405.3.4.1 Privacy for Non-Separated Facilities. Where shared facilities are provided per Section 403.2 (6), each water closet utilized by the public or employees shall occupy a separate compartment with walls that extend from the floor to the ceiling and a lockable door enclosing the fixtures to ensure privacy. The common lavatory area shall not be closed off by a door to the remainder of the building. (Ord. of 1-19-2017(5); Ord. of 7-20-2017(1); )

(Ord. of 7-18-2019(31), § 1, Ord. of 12-5-2019(48), § 2, Ord. of 02-25-2021(36), § 1, Ord. of 5-12-2022(14), § 1, Ord. of 7-14-2022(15), § 1)

Ask a question about Savannah law

Corpus searches the Savannah sections it holds and shows the ones that match, with their citations. Free, no sign-in.