§ 9.8.6 — General Lighting Standards
Code of Ordinances of the City of Savannah, Georgia (Division II) (enCodePlus online edition as published 2026-11-20) · Savannah Code of Ordinances, pt. 8, ch. 3., art. 9.0, art. 9.8, § 9.8.6
Corpus is an independent public-information project, not the official City of Savannah website. Stable reference: corpuslaw.us/code/e2688fb8-9b24-42f5-8335-4ab4b68a43a0
9.8.6 General Lighting Standards
(a) Maximum Lighting Height Unless otherwise specified in Sec. 9.8.7, all outdoor lighting, including building mounted lighting, shall be no greater than 15 feet above grade for non cut-off lights and 35 feet above grade for full cut-off lights. Figure 9.8-1 Maximum Lighting Height [image omitted; see the official code] (a) Light Location Pole-mounted lighting shall not be located within a required buffer except for the Off-street Parking Lot and Street Yard buffers. (b) Maximum Light Levels (i) All site lighting shall be designed so that the level of illumination at any one point within a site does not exceed 15 foot-candles, except where otherwise established in Sec. 9.8.7 below. (ii) Unless otherwise specified in Sec. 9.8.7 below, the maximum light level permitted at the property line shall be as follows: (1) One-half (0.5) foot-candle at any property line adjacent to a Conservation or Residential zoning district or a conforming residential use; (2) One (1) foot-candle at any property line abutting any Mixed-use or Nonresidential zoning district; or (3) Three (3) foot-candles at any property line along any street rights-of-way. (iii) Where off-site lighting causes onsite lighting levels to exceed the permitted foot-candles, no increase in lighting levels will be permitted.
Ask a question about Savannah law
Corpus searches the Savannah sections it holds and shows the ones that match, with their citations. Free, no sign-in.