§ 302.48 — Data center
Code of Ordinances of the City of South Fulton, Georgia (Codified through Ordinance No. 2026-022, enacted July 14, 2026. (Supp. No. 13, Update 2)) · South Fulton Code of Ordinances § 302.48
Corpus is an independent public-information project, not the official City of South Fulton website. Stable reference: corpuslaw.us/code/2cc9f2eb-a3b0-41f1-bc5c-81e76df31df3
Sec. 302.48. - Data center.
(a) Minimum lot area shall be 20 acres. (b) Transitional height restrictions. Where a data center use adjoins property that is used for single-family residential purposes, the height of such data center use shall be limited to 40 vertical feet for a horizontal distance of 100 feet as measured from the common property line. (c) Landscape strip. Where a data center use adjoins a public road, a planted landscape strip 50 feet wide shall be provided adjacent to the existing or dedicated right-of-way. Natural topography and existing vegetation, supplemented with new evergreen vegetation as needed, may be substituted for landscaping when found by the Director to provide appropriate screening. (d) Buffer. Where a data center use adjoins property that is used for residential purposes a buffer subject to the following requirements shall be required: (1) Minimum Buffer Width: 100 feet. (2) Vegetation. Where a buffer is required, the first 25 feet along the property line shall remain in an undisturbed, natural state, except for approved fencing, access and utility improvements. The remaining buffer may be disturbed and graded. If the buffer is disturbed, a minimum of three rows of evergreen shrubs at least four feet in height at planting shall be planted within the area of disturbance as needed to provide screening. (e) Building facades. (1) Building facades that face adjacent public roads and exceed a length of 250 feet shall be articulated through changes in the plane of the facade, installation of windows, recessed panels, trellis features, landscaping, wall articulation, arcades, or other features. (2) Loading bays located in building facades that face adjacent public roads or adjacent residential uses shall be screened from view. (3) Equipment used for cooling, ventilating, or powering the facility, including emergency power generators and other emergency power supply equipment, when located closer to an adjacent public road or adjacent residential use than a principal building, must be contained within an enclosed building or be encompassed on three sides by an opaque barrier extending at least 12 inches in height above the mechanical equipment and screened from view with dense vegetation. (f) Lights. Exterior lighting shall be designed and constructed with fully shielded fixtures that direct light downward and into the interior of the property and away from adjacent roads and adjacent properties. (g) Maximum sound level. (1) Nighttime. Between 11:00 p.m. and 7:00 a.m., the data center shall not generate noise in excess of 55 dB(A) or 10 dB(A) above ambient levels (whichever is more), when measured at the property boundary line shared with a residential use. (2) Daytime. Between 7:00 a.m. and 11:00 p.m., the data center shall not generate noise in excess of 65 dB(A) or 10 dB(A) above ambient levels (whichever is more), when measured at the property boundary line shared with a residential use. (3) Use of backup generators that exceed the maximum sound levels is permitted during emergency power outages. Testing of backup generators is limited to the hours between 9:00 a.m. and 5:00 p.m. (h) Substations. Substations are considered accessory uses to data centers and shall not be located within 300 feet of an adjacent public road. An energy use study shall be completed prior to the issuance of a land disturbance permit. (i) Parking. Data centers must provide a minimum parking of three spaces per thousand gross square feet of office space to be occupied within the development.
(Ord. No. 2024-034, § 4, 9-24-2024)
Ask a question about South Fulton law
Corpus searches the South Fulton sections it holds and shows the ones that match, with their citations. Free, no sign-in.