§ 408.07 — Standards for designated uses or lighting types
Code of Ordinances of the City of South Fulton, Georgia (Codified through Ordinance No. 2026-022, enacted July 14, 2026. (Supp. No. 13, Update 2)) · South Fulton Code of Ordinances § 408.07
Corpus is an independent public-information project, not the official City of South Fulton website. Stable reference: corpuslaw.us/code/33a25d14-ddf6-4a7d-80a1-cbaaf6f6fac1
Sec. 408.07. - Standards for designated uses or lighting types.
All lighting not directly associated with the uses or lighting types designated below shall conform to the lighting standards described in this Ordinance, with the exception that this Section 408.07 shall not be construed to overrule any standards established in any Overlay District or as established in Article 3. (a) Outdoor sports, recreation fields, or performance areas. Lighting of outdoor recreational facilities (public or private), such as, but not limited to, outdoor athletic fields, courts, tracks, special event or show areas shall meet the requirements of this Section. (1) Facilities designed for municipal leagues, elementary to high school levels of play and training fields for recreational or social levels of play, college play, semi-professional, professional or national levels of play shall utilize luminaries with minimal uplight consistent with the illumination constraints of the design. Where fully shielded fixtures are not utilized, acceptable luminaries shall include those which: a. Are provided with internal and/or external glare control louvers or lenses, and are installed so as to minimize uplight and offsite light trespass and glare; and b. Are installed and maintained so as to avoid aiming no more than 2.5 times the mounting height. (2) Illuminance. All lighting installations shall be designed to achieve the illuminance levels for the activity as recommended by the Illuminating Engineering Society of North America (IESNA RP-6). (3) Off-site spill. The installation shall also limit off-site spill (off the parcel containing the sports facility) to the maximum extent possible consistent with the illumination constraints of the design. For all recreational or social levels of play and training fields, as well as, performance areas, illumination levels shall not exceed 1.5 foot-candles at any location along any non-residential property line, and 0.5 foot-candles at any location along any residential property line. (4) Curfew. All events shall be scheduled so as to complete all activity no later than 10:30 p.m. Illumination of the playing field, court or track shall be permitted after the curfew only to conclude a scheduled event that was unable to conclude before the curfew due to unusual circumstances. Field lighting for these facilities shall be turned off within 30 minutes after the last event of the night. (5) Setback. All light poles shall be set back the greater of 50 feet or one foot for every foot in height from any residential property line or right-of-way. (b) Service station canopies and parking structures. (1) All luminaries mounted on or recessed into the lower surface of service station canopies and parking structures shall be fully shielded and utilize flat lenses. (2) The total light output of luminaries mounted on the lower surface, or recessed into the lower surface of the canopy, and any lighting within signage or illuminated panels over the pumps, shall not exceed 50 foot-candles. (3) The total light output of illuminated areas of a service station other than as detailed in Section 408.07(b)(2) above shall not exceed 15 foot-candles. (4) Illuminance levels for the interior of parking structures, where interior lighting is visible from outside the structure, shall conform to the IESNA recommendation (RP-20). (5) Lights shall not be mounted on the top or sides of a canopy and the sides of a canopy shall not be illuminated. (c) Security lighting. (1) Security lighting shall be directed toward the targeted area. (2) Sensor activated lighting must be located in such a manner as to prevent direct glare and lighting into properties of others or into a public right-of-way, and the light shall not be triggered by activity off the property. (d) Pedestrian path lighting. Lighting post shall not exceed 16 feet from the finished grade. (e) Architectural accent lighting. (1) Fixtures used to accent architectural features, materials, colors, style of buildings, landscaping, or art shall be located, aimed and shielded so that light is directed only on those features. Such fixtures shall be aimed or shielded to minimize light spill into the dark night sky in conformance with the luminaire standards. (2) Lighting fixtures shall not generate glare, or direct light beyond the facade onto a neighboring property, streets or into the night sky. (f) Temporary lighting permits. (1) Permits for temporary lighting will be granted by the CDRA Department if the total output from the luminaries does not exceed 50 foot-candles and the following conditions apply: a. The purpose for which the lighting is proposed can be completed within 30 days, except that the permit for a major construction project may extend to completion. b. The proposed lighting is designed in such a manner as to minimize light trespass and glare. c. Permits issued for temporary recreational lighting shall be extinguished by 10:30 p.m. (2) The application for the Temporary Lighting Permit shall include, but not be limited to, the following information: a. Name and address of applicant and property owner; b. Location of proposed luminaire(s); c. Date and times for the lighting; d. Type, wattage and lumen output of lamp(s); e. Type and shielding of proposed luminaires; f. Intended use of the lighting; g. Duration of time for requested exemption; h. The nature of the exemption; and i. The means to minimize light trespass and glare. (g) Commercial parking areas. (1) All lighting fixtures servicing parking lots, except floodlights, shall be cutoff fixtures, directed downward and not toward buildings or other areas. (2) The minimum illumination level for a parking lot shall be 0.4 foot-candles at grade level and the ratio of the average illumination to the minimum illumination shall not exceed 4:1. (3) Floodlights should be aimed or shielded to minimize uplight. (4) Light poles used in parking lots shall not exceed 35 feet in height. (h) Streetlights. All streetlight fixtures new, repaired (outside of normal maintenance) or replaced fixtures shall be cutoff.
Ask a question about South Fulton law
Corpus searches the South Fulton sections it holds and shows the ones that match, with their citations. Free, no sign-in.
