For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 21A-1.6 — General development standards

Revised Ordinances of Honolulu (2026 S-11: Supplement 11, Ordinance No. 26-1 through Ordinance No. 26-18, June 30, 2026) · Revised Ordinances of Honolulu § 21A-1.6

Corpus is an independent public-information project, not the official City of City and County of Honolulu website. Stable reference: corpuslaw.us/code/953bd330-fff6-425a-bf03-25a15b83f63e

§ 21A-1.6 General development standards.

All development within a special flood hazard area requires a permit, and the development must conform with the following. (1) Designed and adequately anchored to prevent flotation, collapse, or lateral movement resulting from hydrodynamic and hydrostatic loads, including effects from buoyancy caused by the base flood. (2) Constructed of flood-resistant materials. (3) Constructed by methods and practices that minimize flood damage. (4) Constructed with electrical, heating, ventilation, plumbing, air conditioning, and other service facilities that are designed or located at or above the design flood elevation, so as to prevent water from entering or accumulating within the components during conditions of flooding. (5) Provided with adequate drainage to prevent or minimize damage in accordance with the storm drainage standards of the department and applicable codes. (6) For new or replacement potable water system and facilities, designed and constructed to minimize or eliminate infiltration of flood waters into the systems. (7) For new or replacement sanitary sewer system and waste disposal systems, designed, located, and constructed to minimize or eliminate infiltration, impairment, and contamination to or from the system. (8) Manufactured homes. (A) Manufactured homes that are placed or substantially improved within special flood hazard areas: (i) Must be elevated on a permanent foundation so that the lowest floor of the manufactured home is elevated to or above the design flood elevation; (ii) Must be securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement; and (iii) The chassis must be supported by reinforced piers or other foundation elements of at least equivalent strength that are no less than 36 inches in height above grade. (B) Manufactured homes that are placed or substantially improved within coastal high hazard areas must meet the requirements of § 21A-1.9. (9) Recreational vehicles. Recreational vehicles placed within a special flood hazard area must either: (A) Be on site for fewer than 30 consecutive days; (B) Be fully licensed and ready for highway use (a recreational vehicle is ready for highway use if it is on wheels or a jacking system, is attached to the site only by quick disconnect type utilities and security devices, and has no permanently attached additions); or (C) Meet the requirements for manufactured homes and the standards for the applicable special flood hazard area. (10) A structure that straddles two or more special flood hazard areas must comply with the standards of the special flood hazard area that is considered to have the most stringent or restrictive standards. (11) For watercourse alteration or relocation, ensure the flood carrying capacity of the altered or relocated portion of the watercourse is maintained. (12) Prior to the commencement of grading, grubbing, or other construction activities within a special flood hazard area, two certified flood zone elevation stakes marking base flood elevations on the property must be placed in the ground by a licensed surveyor and documented with the department. These stakes must remain on the property and be maintained until the department approves the completion of construction. Stakes may be moved and re-established in order to facilitate construction activities and department inspections. (13) New subdivisions and other proposed developments (including proposals for manufactured home parks and subdivisions) greater than 50 lots or 5 acres, whichever is less, must include base flood elevation data on the preliminary maps. (14) Subdivision proposals and other proposed new development must be reviewed to determine whether the proposals will be reasonably safe from flooding. If new development is in a flood area, the proposals must be reviewed to ensure that: (A) All proposals are consistent with the need to minimize flood damage within the flood-prone area; (B) All public utilities and facilities, such as sewer, gas, electrical, and water systems are located and constructed to minimize or eliminate flood damage; and (C) Adequate drainage is provided to reduce exposure to flood hazards. (1990 Code, Ch. 21A, Art. 1, § 21A-1.6) (Added by Ord. 14-9; Am. Ord. 26-10)

Ask a question about City and County of Honolulu law

Corpus searches the City and County of Honolulu sections it holds and shows the ones that match, with their citations. Free, no sign-in.