§ 16-13.5 Size of safe room.

The safe room must be designed to provide a minimum of 7 square feet per person for one- and two-family dwellings and 10 square feet per person for other types of dwellings, based on usable floor area. Usable floor area is defined as the protected occupant area between the safe room walls at the level of fixed seating, where fixed seating exists, minus the area of sanitary facilities or other items that impede usage of the safe room area. Occupant load for a dwelling must not be less than the number of bedrooms plus one. The room does not need to exceed 120 square feet. (1990 Code, Ch. 16, Art. 13, § 16-13.5) (Added by Ord. 12-34; Am. Ord. 24-15)