Sec. 15-86. - Method of measuring noise.

(a) Equipment. Noise measurements shall be made with a sound level meter, type 1 or type 2, manufactured according to the specifications of the American National Standards Institute, USA Standard Specification for General Purpose Sound Level Meters (S1.4-1971), and Preferred Center Frequencies for Acoustical Measurements (S1.6-1960), or any subsequent nationally adopted standard superseding such standards. (b) Location and interpretation of measurements. Noise measurements shall be made at the nearest lot line of premises from which a noise complaint is received, and shall be made at a height of at least three feet above the ground and at least three feet away from walls, barriers, obstructions or sound-reflective surfaces. Where the nature of the noise permits, the slow response setting shall be used to obtain the noise level on the sound level meter.