Sec. 3-51. - Anchoring and supports.

(a) Generally. Signs, sign structures and appendages shall be designed and constructed to resist wind and seismic forces as specified in this section. All bracing systems shall be designed and constructed to transfer lateral forces to the foundations. For signs on buildings, the dead and lateral loads shall be transmitted through the structural frame of the building to the ground in such manner as not to overstress any of the elements thereof. (b) Wind resistance. The overturning moment produced from lateral forces shall in no case exceed two-thirds of the dead-load resisting moment. Uplift due to overturning shall be adequately resisted by proper anchorage to the ground or to the structural frame of the building. The weight of earth superimposed over the footing may be used in determining the dead-load resisting moment. Such earth shall be carefully placed and thoroughly compacted. (c) Calculation of wind load. For the purpose of design, wind pressure shall be taken upon the gross area of the vertical projection of all signs and sign structures at not less than 20 pounds per square foot for those portions less than 40 feet above the ground and at not less than 30 pounds per square foot for those portions more than 40 feet above the ground. In calculating wind pressure on curved surfaces such as cylindrical or spherical signs or sign structures, this pressure shall be assumed to act on six-tenths of the projected area. In all open frame signs or sign structures, the area used in computing wind pressure shall be 1½ times the net area of the framing members exposed to the wind. (d) Allowable stresses. The design of wood, concrete or steel members shall conform to the requirements of an approved testing agent. The working stresses of wire rope and its fastenings shall not exceed 25 percent of the ultimate strength of the rope or fasteners. (e) Supports. The supports for all signs or sign structures shall be placed in or upon private property and shall be securely built, constructed and erected in conformance with the requirements of this article.

(Code 2017, § 3-52)

Ask a question about Cedar Falls law

Corpus searches the Cedar Falls sections it holds and shows the ones that match, with their citations. Free, no sign-in.