§ 7-170 — Uniform Plumbing Code; amendments
Code of Ordinances of the City of Cedar Falls, Iowa (Codified through Ordinance No. 3140, enacted March 16, 2026. (Supp. No. 27)) · Cedar Falls Code of Ordinances § 7-170
Corpus is an independent public-information project, not the official City of Cedar Falls website. Stable reference: corpuslaw.us/code/c4fb608e-77bb-4047-ade7-188f0d33bbb7
Sec. 7-170. - Uniform Plumbing Code; amendments.
(a) The provisions of this section specify certain amendments, by deletion, addition or substitution, of the 2021 Edition of the Uniform Plumbing Code ("UPC"). Where this section states that a section, subsection, enumeration or exception is deleted, only the specific section, subsection, enumeration or exception is deleted. Where this section states that a part, section or subsection is deleted in its entirety, all references listed thereafter associated with this specific part of section (with subsections, enumerations and exceptions) or subsection (with enumerations and exceptions) are deleted. 2021 UPC Chapter 1 Amendments (1) Subsection 102.2, Existing Construction, is amended by adding the following at the end of the subsection: If an existing building is damaged by fire or otherwise or altered in such a manner as to require the replacement of 50 percent or more of the plumbing equipment, the entire building shall be made to conform to the requirements of this article for new buildings. If the type of occupancy of an existing building is partially or entirely changed, the plumbing system shall be made to conform to the requirements of this article for the new type of occupancy. (2) Section 103.1 is amended by adding the following new subsections: 103.1.1 Conflict of Interest. It shall be unlawful for the plumbing inspector to engage in the business of the sales, installation or maintenance of plumbing equipment, either directly or indirectly, and the inspector shall have no financial interest in any concern engaged in such business in the city, at any time, while holding the office provided for in this division. 103.1.2 Records. The plumbing inspector shall keep records of sewer connections from city mains to the property line and from the property line to each building connected to city services. 103.1.3 Interpretation of Regulations. The plumbing inspector shall have full power to exercise judgment in a reasonable and proper manner and rule accordingly on all special cases in regard to any matters in this article or not specifically covered thereby, subject to section 107.0 pertaining to appeals. (3) Subsection 103.2, Liability, is deleted in its entirety and a new subsection 103.2, Liability, is substituted in lieu thereof, as follows: 103.2 Liability. The building official, or his or her authorized representative charged with the enforcement of this code, acting in good faith and without malice in the discharge of his or her duties for the city, shall not thereby render himself or herself personally liable for any damage that may accrue to persons or property as a result of any act or by reason of any act or omission in the discharge of his or her duties. Any suit brought against the city or the building official or employee because of such act or omission performed by him or her in the enforcement of any provisions of such codes or other pertinent laws or ordinances implemented through the enforcement of this code or enforced by the inspection services division shall be defended by the city until the final termination of such proceedings, and any judgment resulting therefrom shall be assumed by the city. This code shall not be construed to relieve from or lessen the responsibility of any person owning, operating or controlling any building or structure for any damages to persons or property caused by defects, nor shall the inspection services division of the city be held as assuming any such liability by reason of the inspections authorized by this code or any certificates of inspection issued under this code. (4) Subsection 103.3.1, Licensing, is deleted in its entirety and a new subsection 103.3.1, Licenses Required, is substituted in lieu thereof, as follows: 103.3.1 Licenses Required. (a) No person shall engage in the business of installing, maintaining, altering or repairing any plumbing system within the scope of this article unless such person has obtained from the State of Iowa board of plumbing examiners and appeals, a master plumber's business license, nor shall any such business or dealer employ any but licensed master plumbers, journeyman plumbers or apprentice plumbers employed by and working under the direction of a holder of the license for one of the classes of licenses prescribed by this article. (b) All plumbing contractors not currently registered by the city shall pay a one-time registration fee as set by the city council. (c) A plumbing business, other than pipe layers, shall show proof of a state issued master plumbing contractor license and shall execute and file with the city building official (or a specified inter-governmental agency if so designated by the building official) a certificate of insurance written by a company authorized to transact business in the state, in limits established by Iowa law. (d) Upon payment of the annual license fee set by city council, a pipe layer's license may be issued to a company that meets the insurance requirements of subsection (b) of this section set by the city and may be required to take an exam approved by the plumbing inspector. (e) Said certificate of insurance shall be issued by December 31 of each year, and shall be refiled on or before said date for each subsequent year and shall be in continuous full force and effect. That it is the intent and purpose of said certificate of insurance to also bind the individual, company, firm, association or partnership, whether it be trade name, corporation, or other business association or arrangement with which the principal is associated. (5) Subsection 104.3.2, Plan review fees, is deleted in its entirety. (6) Subsection 104.4.1, Approved plans or construction documents, is deleted in its entirety, and a new subsection 104.4.1, Approval of construction documents, is substituted in lieu thereof, as follows: 104.4.1 Approval of Construction documents. When the building official issues a permit, the construction documents shall be approved, in writing or by stamp, as "Reviewed for Code Compliance." One set of construction documents so reviewed shall be retained by the building official. The other set shall be returned to the applicant, shall be kept at the site of the work and shall be open to inspection by the building official or a duly authorized representative. (7) Subsection 104.4.3 Expiration, is deleted in its entirety and a new subsection 104.4.3, Expiration, is substituted in lieu thereof, as follows: 104.4.3 Expiration. Every permit issued under the provisions of this code shall expire 12 months from the date of issue, unless the application is accompanied by a construction schedule of specific longer duration, in which instance the permit may be issued for the time period of the construction schedule, with the approval of the building official. If the work has not been completed, including all required inspections, by the expiration date of the permit, no further work shall be done until the permit has been renewed by the owner, or the owner's agent, and payment of the renewal fee has been received. The building official is authorized to grant one or more extensions of time, for periods of not more than six months each, without payment of the renewal fee. Extensions shall be requested by the owner or the owner's agent and justifiable cause demonstrated by the owner. (8) Subsection 104.4.4, Extensions, is deleted in its entirety. (9) Subsection 104.5, Fees, is deleted it in its entirety and a new subsection 104.5, Fees, is substituted in lieu thereof, as follows: 104.5 Fees. 104.5.1 Payment of fees. A permit shall not be valid until the fees prescribed by law have been paid, nor shall an amendment to a permit be released until the additional fee, if any, has been paid. 104.5.2 Schedule of permit fees. Where a permit is required, a fee for each permit shall be paid as required, in accordance with the schedule as established by the city. 104.5.3 Permit valuations. The applicant for a permit shall provide an estimated permit value at time of application. Permit valuations shall reflect the total value of work, including materials and labor, for which the permit is being issued, such as electrical, gas, mechanical, plumbing equipment and permanent systems. If, in the opinion of the building official, the valuation is underestimated on the application, the permit shall be denied, unless the applicant can show detailed estimates to meet the approval of the building official. Final permit valuation shall be set by the building official. 104.5.4 Work commencing before permit issuance. Any person who commences any work before obtaining the necessary permits shall be subject to a fee established by the building official that shall be in addition to the required permit fees. 104.5.5 Related fees. The payment of the fee for the construction, alteration, removal or demolition for work done in connection to or concurrently with the work authorized by a building permit shall not relieve the applicant or holder of the permit from the payment of other fees that are prescribed by law. 104.5.6 Refunds. Refunds may be available only when work under the permit has not been commenced. Refunds may be available only for permit fees that exceed $100.00. If granted, the refund shall be eighty percent of the permit fee. 104.5.7 Reinspections. A reinspection fee shall be permitted to be assessed for each inspection or reinspection where such portion of work for which inspection is called is not complete or where required corrections have not been made. This provision shall not be interpreted as requiring reinspection fees the first time a job is rejected for failure to be in accordance with the requirements of this code, but as controlling the practice of calling for inspection before the job is ready for inspection or reinspection. Reinspection fees shall be permitted to be assessed where the approved plans are not readily available to the inspector, for failure to provide safe access on the date for which the inspection is requested, or deviating from plans requiring approval of the City. (10) Subsection 105.2.6, Reinspections, is deleted in its entirety. (11) Section 106.0, Violation and Penalties, is deleted in its entirety and a new Section 106.0, Violations, is substituted in lieu thereof, as follows: 106.0 Violations. 106.1 Unlawful acts. It shall be unlawful for any person, firm or corporation to erect, construct, enlarge, alter, extend, repair, move, remove, demolish or occupy any building, structure or equipment regulated by this code, or cause same to be done, in conflict with or in violation of any of the provisions of the code. 106.2 Notice of Violations. The building official is authorized to serve a notice of violation or order on the owner and person responsible for the erection, construction, enlargement, alteration, extension, repair, movement, removal, demolition, or occupation of any building or structure in violation of the provisions of this Code, or in violation of a detail statement or a plan approved thereunder, or in violation of a permit or certificate issued under the provisions of this Code. Such order shall direct the discontinuance of the illegal action or condition and the abatement of the violation. 106.3 Prosecution of Violation. If the notice of violation is not complied with in the time prescribed by such notice, the building official is authorized to request the city attorney to institute the appropriate proceeding at law or in equity to restrain, correct or abate such violation, or to require the removal or termination of the unlawful occupancy of the building or structure in violation of the provisions of this Code or of the order or direction made pursuant thereto. 106.4 Violation Penalties. Any person who violates a provision of this code or fails to comply with any of the requirements thereof or who erects, constructs, alters or repairs a building or structure in violation of the approved construction documents or directive of the building official, or of a permit or certificate issued under the provisions of this code shall be deemed guilty of a municipal infraction punishable as provided in section 1-9 of the Code of Ordinances of the city. (12) A new Section, 106A.0, Stop work order, is added as follows: 106A.0 Stop work order. 106A.1 Authority. Where the building official finds any work regulated by this code being performed in a manner contrary to the provisions of this code or in a dangerous or unsafe manner, the building official is authorized to issue a stop work order. 106A.2 Issuance. The stop work order shall be in writing and shall be given to the owner of the property, the owner's authorized agent or the person performing the work. Upon issuance of a stop work order, the cited work shall immediately cease. The stop work order shall state the reason for the order and the conditions under which the cited work is authorized to resume. 106A.3 Emergencies. Where an emergency exists, the building official shall not be required to give a written notice prior to stopping the work. 106A.4 Failure to Comply. Any person who shall continue any work after having been served with a stop work order, except such work as that person is directed to perform to remove a violation or unsafe condition, shall be deemed guilty of a municipal infraction punishable as provided in section 1-9 of the Code of Ordinances of the city. (13) Section 107.0, Board of Appeals, is deleted in its entirety and a new Section 107.0, Board of Appeals, is substituted in lieu thereof, as follows: 107.0 Board of Appeals. 107.1 Membership; Appointment of Members; Term of Office. (a) The board of plumbing appeals shall consist of five members appointed each year, one owner, officer, director, shareholder or employee of a plumbing company, one master plumber, two journeyman plumber and one public member, each appointed for a period of four years. The plumbing inspector shall serve as secretary to the board but is nonvoting. Appointments shall be made by the mayor, with the approval of the city council. Should a vacancy on the board occur, it shall be the duty of the secretary of the board to notify the mayor of the vacancy, and the mayor and city council shall, at a regular meeting, as soon possible thereafter, appoint a new member to the board to fill the vacancy for the unexpired term. (b) Expiration of appointments shall be staggered, so that one member is appointed or reappointed each year. Terms of appointment shall expire on December 31. If the mayor and city council fail to appoint at the scheduled time, the expired term member will be held over until re-appointment or replacement. (c) In so far as reasonably practicable, appointees for membership on the board shall be residents of the city, or, if that is not reasonably practicable, shall have a place of employment in the city. Appointees who are neither residents of the city nor who have a place of employment in the city may be eligible for appointment to the board upon a finding of the unavailability of qualified applicants, as determined by the mayor. Any person who is a member of the board on the date of adoption of this ordinance who does not meet the qualifications for membership set forth herein shall continue to be eligible to serve as a member of the board until both the expiration of his current term and the member's nonreappointment by the mayor to an additional term. 107.2 Meetings; Records. (a) All meetings of the plumbing appeals board shall be held in the council chambers, or other location indicated in a public notice posted at least 24 hours prior to any meeting. (b) Three members of the board shall constitute a quorum for the transacting of all business, but any action taken by the board shall require a majority vote of all members of the board. (c) The board shall annually elect one of its members as the chair of the board. (d) The secretary of the board shall keep a record of the board meetings. 107.3 Compensation of Members. The members of the plumbing board of appeals shall serve without compensation. 107.4 Appeals. (a) Any person shall have the right to file an appeal with the plumbing board of appeals for a review of any decision of the plumbing inspector, provided that such appeal is made in writing within ten days after having been notified of such decision by the plumbing inspector. Upon receipt of such appeal, the board of appeals shall proceed to determine whether the action of the plumbing inspector complies with this article and shall make a decision in accordance with its findings within ten days of receiving the appeal. No appeal shall be considered unless the appeal is filed within the period of ten days. The board of appeals shall have no authority to waive requirements of this code. (b) An appeal to the city council of any ruling of the board may be made by filing a written notice of such appeal with the city clerk within ten days from the date of the ruling being appealed. The city council shall give the appellant and the board a minimum of five days written notice by certified mail of the date, time and location of hearing of said appeal. All interested persons shall be given the opportunity to be heard at such hearing and the city council may affirm, modify or overrule the action of the board based upon the evidence submitted before the city council. 2021 UPC Chapter 2 Amendments (14) Section 218.0 is amended by adding the following definition: Pipe layer: A person approved by the city to install the building sewer. 2021 UPC Chapter 3 Amendments (15) Section 306.0, Industrial Wastes, is amended by adding a new subsection 306.3 as follows: 306.3 Any industrial or commercial property connecting to the city sanitary sewage system shall only do so after the installation of an inspection manhole on said property. This manhole shall be readily accessible for inspection and/or testing by city or state personnel at all times. Minimum size of the manhole shall be 36 inches. An exception to this provision may be made only in the judgment of the authority having jurisdiction. (16) Subsection 312.6, Freezing Protection, is amended by adding the following sentence at the end of the subsection: Prior written approval from the Inspection Services Division is required prior to installation of piping above 42" frost depth. (17) Subsection 314.2, Tunneling and Driving, is amended by adding the following sentence at the end of the subsection: Boring shall only be allowed with prior approval of the authority having jurisdiction. 2021 UPC Chapter 4 Amendments (18) Subsection 402.6.1, Closet Rings (Closet Flanges), is deleted in its entirety and a new subsection 402.6.1, Closet Rings (Closet Flanges), is substituted in lieu thereof, as follows: 402.6.1 Closet Rings (Closet Flanges). Closet rings (closet flanges) for water closets or similar fixtures shall be of an approved type and shall be bronze, copper, hard lead, cast-iron, galvanized malleable iron, ABS, PVC, or other approved materials. Each such closet ring (closet flange) shall be approximately seven inches (178 mm) in diameter and, where installed, shall, together with the soil pipe, present a 1½ inch (38 mm) wide flange or face to receive the fixture gasket or closet seal. Caulked-on closet rings (closet flanges) shall be not less than one-quarter of an inch (6.4 mm) thick and not less than two inches (51 mm) in overall depth. Closet rings (closet flanges) shall be burned or soldered to lead bends or stubs, shall be caulked to cast-iron soil pipe, shall be solvent cemented to ABS and PVC, and shall be screwed or fastened in an approved manner to other materials with the top surface ¼ inch above the finished floor. Closet bends or stubs shall be cut off so as to present a smooth surface even with the top of the closet ring before rough inspection is called. Closet rings (closet flanges) shall be adequately designed and secured to support fixtures connected thereto. (19) Subsection 408.5, Finished Curb or Threshold, is amended by adding the following at the end of the subsection: Zero entry or curbless showers require submission of design and approval by the Inspection Services Division prior to a permit being issued. Curbless showers require a 2'0" wet zone at the perimeter of the shower and requires waterproofing. (20) Table 422.1, Minimum Plumbing Facilities, is deleted in its entirety, and the following Table 2902.1, Minimum Number of Required Plumbing Fixtures, is substituted in lieu thereof, as follows: (P) TABLE 2902.1 MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES a (See Sections 2902.1.1 and 2902.2) No. | CLASSIFICATION | DESCRIPTION | WATER CLOSETS (URINALS SEE SECTION 424.2 OF THE INTERNATIONAL PLUMBING CODE) | LAVATORIES | BATHTUBS/SHOWERS | DRINKING FOUNTAINS (SEE SECTION 410 OF THE INTERNATIONAL PLUMBING CODE) | OTHER Male | Female | Male | Female 1 | Assembly | Theaters and other buildings for the performing arts and motion pictures d | 1 per 125 | 1 per 65 | 1 per 200 | —- | 1 per 500 | 1 service sink Nightclubs, bars, taverns, dance halls and buildings for similar purposes d | 1 per 40 | 1 per 40 | 1 per 75 | —- | 1 per 500 | 1 service sink Restaurants, banquet halls and food courts d | 1 per 75 | 1 per 75 | 1 per 200 | —- | 1 per 500 | 1 service sink Casino gaming areas | 1 per 100 for the first 400 and 1 per 250 for the remainder exceeding 400 | 1 per 50 for the first 400 and 1 per 150 for the remainder exceeding 400 | 1 per 250 for the first 750 and 1 per 500 for the remainder exceeding 750 | —- | 1 per 1,000 | 1 service sink Auditoriums without permanent seating, art galleries, exhibition halls, museums, lecture halls, libraries, arcades and gymnasiums d | 1 per 125 | 1 per 65 | 1 per 200 | —- | 1 per 500 | 1 service sink Passenger terminals and transportation facilities d | 1 per 500 | 1 per 500 | 1 per 750 | —- | 1 per 1,000 | 1 service sink Places of worship and other religious services d | 1 per 150 | 1 per 75 | 1 per 200 | —- | 1 per 1,000 | 1 service sink Coliseums, arenas, skating rinks, pools and tennis courts for indoor sporting events and activities | 1 per 75 for the first 1,500 and 1 per 120 for the remainder exceeding 1,500 | 1 per 40 for the first 1,520 and 1 per 60 for the remainder exceeding 1,520 | 1 per 200 | 1 per 150 | —- | 1 per 1,000 | 1 service sink Stadiums, amusement parks, bleachers and grandstands for outdoor sporting events and activities f | 1 per 75 for the first 1,500 and 1 per 120 for the remainder exceeding 1,500 | 1 per 40 for the first 1,520 and 1 per 60 for the remainder exceeding 1,520 | 1 per 200 | 1 per 150 | —- | 1 per 1,000 | 1 service sink 2 | Business | Buildings for the transaction of business, professional services, other services involving merchandise, office buildings, banks, light industrial, ambulatory care and similar uses | 1 per 25 for the first 50 and 1 per 50 for the remainder exceeding 50 | 1 per 40 for the first 80 and 1 per 80 for the remainder exceeding 80 | —- | 1 per 100 | 1 service sink e 3 | Educational | Educational facilities | 1 per 50 | 1 per 50 | —- | 1 per 100 | 1 service sink 4 | Factory and industrial | Structures in which occupants are engaged in work fabricating, assembly or processing of products or materials | 1 per 100 | 1 per 100 | —- | 1 per 400 | 1 service sink 5 | Institutional | Custodial care facilities | 1 per 10 | 1 per 10 | 1 per 8 | 1 per 100 | 1 service sink Medical care recipients in hospitals and nursing homes b | 1 per room c | 1 per room c | 1 per 15 | 1 per 100 | 1 service sink Employees in hospitals and nursing homes b | 1 per 25 | 1 per 35 | —- | 1 per 100 | —- Visitors in hospitals and nursing homes | 1 per 75 | 1 per 100 | —- | 1 per 500 | —- Prisons b | 1 per cell | 1 per cell | 1 per 15 | 1 per 100 | 1 service sink Reformatories, detention centers and correctional centers b | 1 per 15 | 1 per 15 | 1 per 15 | 1 per 100 | 1 service sink Employees in reformatories, detention centers, and correctional centers b | 1 per 25 | 1 per 35 | —- | 1 per 100 | —- Adult day care and child day care | 1 per 15 | 1 per 15 | 1 | 1 per 100 | 1 service sink 6 | Mercantile | Retail stores, service stations, shops, salesrooms, markets and shopping centers | 1 per 500 | 1 per 750 | —- | 1 per 1,000 | 1 service sink e 7 | Residential | Hotels, motels, boarding houses (transient) | 1 per sleeping unit | 1 per sleeping unit | 1 per sleeping unit | —- | 1 service sink Dormitories, fraternities, sororities and boarding houses (not transient) | 1 per 10 | 1 per 10 | 1 per 8 | 1 per 100 | 1 service sink Apartment house | 1 per dwelling unit | 1 per dwelling unit | 1 per dwelling unit | —- | 1 kitchen sink per dwelling unit; 1 automatic clothes washer connection per 20 dwelling units One- and two-family dwellings and lodging houses with five or fewer guestrooms | 1 per dwelling unit | 1 per 10 | 1 per dwelling unit | —- | 1 kitchen sink per dwelling unit; 1 automatic clothes washer connection per dwelling unit Congregate living facilities with 16 or fewer persons | 1 per 10 | 1 per 10 | 1 per 8 | 1 per 100 | 1 service sink 8 | Storage | Structures for the storage of goods, warehouses, storehouses and freight depots, low and moderate hazard | 1 per 100 | 1 per 100 | —- | 1 per 1,000 | 1 service sink a. The fixtures shown are based on one fixture being the minimum required for the number of persons indicated or any fraction of the number of persons indicated. The number of occupants shall be determined by this code. b. Toilet facilities for employees shall be separate from facilities for inmates or care recipients. c. A single-occupant toilet room with one water closet and one lavatory serving not more than two adjacent patient sleeping units shall be permitted, provided that each patient sleeping unit has direct access to the toilet room and provisions for privacy for the toilet room user are provided. d. The occupant load for seasonal outdoor seating and entertainment areas shall be included when determining the minimum number of facilities required. e. For business and mercantile classifications with an occupant load of 15 or fewer, a service sink shall not be required. f. The required number and type of plumbing fixtures for outdoor swimming pools shall be in accordance with section 609 of the International Swimming Pool and Spa Code. 2021 UPC Chapter 7 Amendments (21) Subsection 713.4, Public Sewer Availability, is deleted in its entirety and a new Subsection 713.4, Public Sewer Availability, is substituted in lieu thereof, as follows: 713.4 Public Sewer Availability. The public sewer may be considered as not being available when such public sewer is more than 200 feet away. Said distance shall be construed as being measured from the public sewer to the nearest property line. The 200 feet distance shall also apply to residences and buildings erected prior to the passage of this chapter. This distance will be considered reasonable for the connection of sewer and water when so ordered by the plumbing inspector or authorized by the building official. (22) Section 714.0, Damage to Public Sewer or Private Sewage Disposal System, is amended by adding a new subsection 714.6, Contamination, as follows: 714.6 Contamination. Any sewer taps, tie-ins and/or sanitary sewer service which is damaged in any way that would allow any subsurface contamination, pollution damage, hazardous or nuisance condition to the public sewer system, shall be the sole responsibility of the property owner to repair and/or maintain and keep in good operating condition. Written notification will be sent to said property owner stating the condition and/or repairs necessary to correct the damage or nuisance condition. If the property owner does not repair the damage or nuisance, the city may contact a plumbing contractor to repair said damage and will assess the property owner for all repairs, or legal action may be taken to correct the condition. 2021 UPC Chapter 11 Amendments (23) Subsection 1101.6.1, Discharge, is deleted in its entirety and a new subsection 1101.6.1, Discharge, is substituted in lieu thereof, as follows: 1101.6.1 Discharge. There shall be no cross-connection to the sanitary sewer and in no instance shall the discharge be to city right-of-way or city streets. Where possible the discharge of said sump shall be by gravity where the city has provided a relief tile behind the city curb or the sump may be connected to the storm sewer or discharged to a drainage ditch except as otherwise approved by the Authority Having Jurisdiction.
(Code 2017, § 7-257; Ord. No. 2870, § 1, 7-5-2016; Ord. No. 2997, § 11, 11-15-2021)
Ask a question about Cedar Falls law
Corpus searches the Cedar Falls sections it holds and shows the ones that match, with their citations. Free, no sign-in.
