§ 9-20 — International Fire Code amendments

Code of Ordinances of the City of Cedar Falls, Iowa (Codified through Ordinance No. 3140, enacted March 16, 2026. (Supp. No. 27)) · Cedar Falls Code of Ordinances § 9-20

Corpus is an independent public-information project, not the official City of Cedar Falls website. Stable reference: corpuslaw.us/code/2ef75211-59c1-4aa9-aacd-987c324bcee6

Sec. 9-20. - International Fire Code amendments.

The International Fire Code, 2021 Edition, adopted by section 9-19, is amended as provided in this section. (1) Section 103.2, Appointment, and section 103.3, Deputies, are deleted, and the following substituted therefor: 103.2 Appointment. The chief of the fire operations division may designate a member of the fire operations division to exercise the powers and perform the duties set forth in this code. (2) Subsection 105.2 Application, is amended by adding the following sentence to the end of the subsection: Application for an operational permit shall be submitted with all required information not less than 30 days prior to the event requiring a permit. (3) Subsection 105.6.30, Open Burning, is deleted in its entirety. (4) Subsection 105.5.42, Pyrotechnic Special Effects Material, is deleted and the following is substituted therefor: Subsection 105.5.42 Pyrotechnic Special Effects Material. The council, upon written request for an application, may grant a permit for the display of fireworks to amusement parks, organizations or groups of individuals as approved by the council when satisfied that such fireworks display will be handled by a competent operator and that adequate protection for public safety has been provided and that adequate fire extinguishing equipment is available. Accident liability protection in an amount of not less than $2,000,000.00 may be required. Additional reference will be found in Code of Iowa § 727.2. (5) Subsection 108.2 Inspections. is amended by adding the following to the end of the subsection: The fire code official at the official's sole discretion may send plans to a qualified agency for review. The fire code official shall designate the review agency for the plans. The applicant shall pay all fees associated with the plan review directly to the outside agency. (6) Subsection 108.2 Inspections, is further amended by adding the following subsection 108.2(a): 108.2(a) All fire protection systems (sprinkler/fire alarm systems) with a square footage over 10,000 feet shall require a third party review. The third party shall be approved by the fire code official. Any building which contains fire pumps, or stand pipes, regardless of square footage, shall require a third party review. The third party shall be approved by the fire code official. (7) Section 108 Inspections, is amended by adding subsection 108.5, Commercial Operations, as follows: 108.5 Commercial Operations. All new commercial business and all new commercial business in existing buildings shall have initial pre-inspection conducted by the fire code official before business is open to the general public, and records updated to reflect new business owners. (8) Section 111, Means of Appeals, including subsections 111.1 through 111.4, is deleted in its entirety, and the following substituted therefor: Section 111 Board of Appeals. In order to determine the suitability of alternate materials and type of construction and to provide for reasonable interpretations of the provisions of this code, the board of appeals shall render decisions upon pertinent matters. The fire chief shall be an ex-officio member of the board. The board shall adopt reasonable rules and regulations for conducting its investigations and shall render all decisions and findings in writing to the fire chief with a duplicate copy to the appellant, and may recommend to the city council such new legislation as is consistent therewith. The board of appeals referred to in this section is the board of appeals created by the building code, as adopted by the city. (9) Section 202, General Definitions, is amended by adding the following definitions: Code official. The chief officer of the fire operations division, the fire marshal, or the fire chief's authorized representative. Cross aisles. Required aisles which permit egress from one main aisle to gather through an allowable use area. Emergency communications center. Black Hawk County Consolidated Communications Dispatch Center. Exhibits. A space or portable structure used for the display of products or services. Flame effect. The combustion of flammable solids, liquids, or gases to produce thermal, physical, visual, or audible phenomena before an audience. Main aisle. That area designated to accommodate the required means of egress width located between the farthest projections of the area designated for use by a tenant and the allowable use area. Maze. A labyrinth of paths throughout a confined area accessible by walking or mobile Mobile catering. Business of selling prepared food from some sort of vehicle. Mobile food truck. A vehicle equipped to cook and sell food. Outdoor assembly event. Private and public events conducted outdoors including, but not limited to, beer gardens and mazes, having a projected attendance of 500 or more persons throughout the event, or confining 50 or more attendees by the permanent or temporary installation of barricades or fencing. Special event. An assembly of persons with a common purpose to watch or participate in an activity that is different than the normal course of business for the location. The event is for a specific time and location. Events may involve entertainment, food/beverage or alcohol services, use of temporary fencing, stands, structures, or power. Events may include, but not be limited to, concerts, circuses, fairs, festivals, parades, tradeshows, exhibits, mazes, or similar celebrations. Special events may also increase, impact, or disrupt normal traffic flow or involved road closures. (10) Section 307, Open Burning and Recreational Fires, is deleted in its entirety. (11) Subsection 405.3, Frequency, is amended by adding the following at the end of the subsection: Fire and evacuation drills in Group E occupancies shall be conducted in accordance with section 100.31 of the Code of Iowa. Fire Drills in Group R, Division 2, Fraternities and Sororities, shall be conducted once per academic semester. (12) Section 503, Fire Apparatus Access Roads, is amended by adding subsection 503.2.9, Load Support, as follows: 503.2.9 Load Support. Fire apparatus access roads shall support a minimum wheel load of 18,000 pounds and/or GVW of 80,000 pounds and meet city engineering road standards. (13) Section 506, Key Boxes, is amended by adding the following subsections 506.3, 506.3.1, 506.3.2, 506.4, 506.4.1, and 506.4.2 thereto: 506.3 Key box. A fire operations division key box shall be installed in each commercial or industrial building in the city which is equipped with a fire detection, fire alarm, or fire suppression system that is monitored by an alarm company with direct connection to the dispatch center of the city, and in each building equipped with an unsupervised local alarm system, and where immediate access to the interior of the building by fire operations division personnel is necessary for life-saving or firefighting purposes. A fire operations division key box shall also be installed in each residential property consisting of three or more residential dwelling units. Each fire operations division key box shall be of a type and shall be installed in a location that is approved by the fire chief or his designee, and shall be installed in accordance with manufacturer's recommendations. Each application for a fire operations division key box shall be submitted to the fire chief or his designee. The cost of purchase and installation of each fire operations division key box shall be paid by the building owner. Each fire operations division key box shall contain the following keys: a. Keys to each locked point of egress, whether on the exterior or interior of the building. b. Keys to each locked mechanical room in the building. c. Keys to each locked electrical room in the building. d. Keys to other areas as determined by the fire chief or his designee. A "fire operations division key box" means a secure box installed on the exterior of a building, containing keys to various locks on the premises of the building, to which only the fire chief or his designee has access. If the building owner changes or causes to be changed any locks such that the keys located in the fire operations division key box will not unlock any of the locks described in this section, it shall be the responsibility of the building owner to furnish to the fire chief or his designee replacement keys to be placed in the fire operations division key box, at the owner's expense. 506.3.1 Elevator Knox Box A fire operations division elevator key box shall be installed in each commercial, industrial and residential building in the city which is equipped with an elevator system. Each fire operations division elevator key box shall be of a type and shall be installed in a location that is approved by the fire chief or his designee, and shall be installed in accordance with manufacturer's recommendations. 506.3.2 Fire Department Connection Caps (FDC) A fire operations division connection (FDC) for water supply to a building from a fire truck shall have locking Knox cap plug installed on all new piping and existing piping, in all sprinkled buildings within the city. Each fire operations division connection locking cap shall be of a type and shall be installed in accordance with manufacturer's recommendations. 506.4 Locking Wall File Cabinets. Generic locking wall file cabinets shall be mounted by the fire alarm control panel. The cabinets shall contained information for fire operations division use. Locking file cabinets shall be approved by the fire code official. The key to file cabinet shall be placed into the key box. 506.4.1 Contents. The cabinets shall contain the following files: 1. Fire alarm as built plans. 2. Sprinkler plans. 3. Emergency contacts. 4. Any other info required by the fire code official. 506.4.2 Mounting Height. Cabinets shall be mounted no higher than 5½ feet measured from the floor. (14) Section 507, Fire Protection Water Supplies, is amended by adding subsection 507.5.1.2, FDC Connections, as follows: 507.5.1.2 FDC Connections. Where a facility or building hereafter constructed or moved into or within the jurisdiction requiring a fire suppression system shall have a fire hydrant located within 100 feet of the buildings FDC connection as measured by an approved route by the fire code official. (15) Subsection 507.5.1, Where required, is amended by deleting exceptions 1 and 2. (16) Subsection 507.5.1.1, Hydrant for standpipe systems, is amended by deleting exception. (17) Subsection 507.5.4, Obstruction, is amended by adding subsection 507.5.5.1 as follows: 507.5.5.1 Fire protection equipment and fire hydrants shall not be hidden by vegetation or other means as determined by fire code official. (18) Subsection 507.5, Fire hydrant systems, is amended by adding the following subsections 507.5.7 and 507.5.8: 507.5.7. Fire hydrants shall be marked by approved method for quick response as determined and approved by fire code official. (Marker flags) 507.5.8. Fire hydrant outlet direction: Fire hydrants shall be positioned so that the 4½-inch port connection is facing in a direction as determined by fire code official. (19) Subsection 510.1, Emergency responder communication coverage in new buildings, is amended by deleting exception 1. (20) Section 903, Automatic Sprinkler Systems, is amended by adding a new subsection 903.1.2, Water supply safety margin, as follows: 903.1.2. Water Supply Safety Margin. Automatic sprinkler systems shall be designed with a minimum of 10 percent or five psi safety margin (whichever is greater) above static pressure in the fire protection systems hydraulic calculations. (21) Subsection 903.4.2, Alarms, is deleted in its entirety and the following new subsection 903.4.2, Alarms, is substituted therefor: 903.4.2. Alarms. An approved weatherproof horn/strobe device shall be mounted directly above a fire operations division connection (FDC) between seven and ten feet in height above grade. Exception: horn/strobe device height and location may be altered by the fire code official as circumstances require in the discretion of the fire code official. (22) Section 903, Automatic Sprinkler Systems, is amended by adding a new subsection 903.7, Zones, as follows: 903.7 Zones. Automatic sprinkler systems zones shall not exceed the area permitted by NFPA 13 or NFPA 13R and shall provide a sprinkler control valve and a water flow device for each normally occupied floor. The location of sprinkler control valves must be approved by the fire code official. (23) Subsection 906.1, Where Required, is amended by deleting the exceptions. (24) Subsection 906.3, Size and Distribution, is amended by adding the following sentence to the end of the subsection: The minimum rating of any required portable fire extinguisher for Class A, B, C, D hazard shall be 2A-10BC. (25) Section 907.1, General, is amended by adding the following subsections: 907.1.4 Fire Alarm Control Panels and Fire Alarm Annunciator Panels. Installation of fire alarm control panels and fire alarm annunciator panels shall be installed in accordance with subsections 907.1.4.1 through 907.1.4.6 907.1.4.1 Fire Alarm Panel Height: Installation of a fire alarm panels shall not exceed six feet in height measured from the floor to the top of panel. Exception: Panel height may be altered by the code official. 907.1.4.2 Number of Fire Alarm Panels in Buildings. Only one listed fire alarm control panel shall be allowed per building and shall lock in the alarm until the system is reset and shall not be canceled by the operation of an audible-alarm silencing switch. This control panel shall only receive alarms signals from the fire protection equipment. 907.1.4.3 Combination Fire/Security Alarm Systems Panels. A listed combination fire/security alarm system panel that meets all the requirements of this code and amendments may be permitted by approval of the fire code official. The fire/security panel shall be capable of providing a signal that can differentiate between the fire and security alarm. 907.1.4.4 Password/PIN Protection Prohibited: Fire alarm control panels and/or fire alarm annunciator panels that require a password/PIN to silence an alarm/supervisory/trouble signal and/or to reset an alarm/supervisory/trouble signal shall prohibited 907.1.4.5 Fire Alarm Annunciator Panels: The fire code official can require the addition of fire alarm annunciator panels based on the size of building and access to the building. These panels shall meet the requirements of section 907.1.4 and 907.2. 907.1.4.6 Fire Alarm Panels: All Fire alarm panels shall be the addressable type system. (26) Subsection 907.2.1, Group A, is amended by deleting the exception contained therein. (27) Subsection 907.2.3, Group E, is amended by adding the following sentence to the end of the first paragraph: New and existing educational occupancies shall have a monitored fire alarm system. (28) Subsection 907.2.9.1, Manual fire alarm system, is amended by deleting exception 2. (29) Subsection 907.2.11.2, Groups R-2, R-3, R-4 and I-1, is amended by adding a fourth subparagraph, as follows: 4. Supervised smoke alarms shall be installed in all common corridors and at the top and bottom of all stairway enclosures in groups R-2, R-4, and I-1 occupancies. In corridors, detectors shall be located within 15 feet of the end of the corridor and in such a way that one detector is located for each 30 feet of corridor length or spaced as allowed by the code. (30) Subsection 907.2.13.2, Fire department communication system, is deleted in its entirety. (31) Subsection 907.3, Fire safety functions, is amended by adding subsection 907.3.5, High velocity low speed fans, as follows: 907.3.5 High Velocity Low Speed Fans (HVLSF). HVLSF shall shut down upon activation of fire alarm system (32) Subsection 907.4.2, Manual fire alarm boxes, is amended by adding the following sentence to the end of the subsection: Where in the opinion of the fire code official manual fire alarm boxes may be used to cause false fire alarms, the fire code official is authorized to modify the requirements for manual fire alarm boxes. (33) Subsection 907.6.4, Zones, is amended by deleting the exception in its entirety and substituting the following exception in lieu thereof: Exception: Automatic sprinkler system zones shall not exceed the area permitted by NFPA13 and shall provide a sprinkler control valve and water flow device for each normally occupied floor. (34) Subsection 907.6.4, Zones, is further amended by adding subsection 907.6.4.3, Zone and address location labeling, as follows: 907.6.4.3 Zone and address location labeling. Fire alarm and/or annunciator panels shall have all zones and address points plainly and permanently labeled as to their location on the outside of the panel or on an easily readable map of the building. (35) Subsection 907.6.6, Monitoring, is amended by adding the following paragraph at the end of the subsection: Each address point identification shall have an alpha/numeric descriptor location. Alpha/numeric descriptor locations area required to be reported to the emergency communications center upon activation of alarm conditions as specified by the fire code official. Supervisory alarm conditions are required to be reported to the fire code official by an approved manner. (36) Subsection 912.1, Installation, is amended by adding subsection 9.12.1.1, as follows: 912.1.1 The fire operations division connection(s) shall be a five inch Storz type connector(s) compatible with hose couplings currently used by Cedar Falls Fire Rescue. (37) Subsection 912.4.1, Locking fire department connection caps, is amended by adding subsection 912.4.1.1, as follows: 912.4.1.1 FDC size minimum fire operations division connection size shall be 5 inch locking Storz type with a locking Knox cap on commercial buildings and 2 ½ inch Cedar Falls thread on residential buildings with a locking Knox cap. (38) Section 912, Fire Department Connections, is amended by adding subsection 912.8, Remote connection, as follows: 912.8. Remote connection. Any building three stories or higher shall have a remote fire operations division connection. Chapter 50 Hazardous Materials General Provisions (39) Subsection 5003.5, Hazardous identification signs, is amended by adding the following sentence to the end of the subsection: Signs shall also comply with the requirements of the Iowa Right to Know Law. Chapter 57 Flammable and Combustible Liquids (40) Subsection 5704.2.132., Above-ground tanks, is amended by adding subsection 5704.2.13.2.4, Existing above-ground tanks hazards, as follows: 5704.2.13.2.4. Existing above-ground tanks hazards. Existing above-ground tanks installations, even if previously approved, that are determined to constitute a hazard by the fire code official, shall not be continued in service. Unsafe tanks shall be removed as required by the fire code official and in accordance with this code.

(Code 2017, § 11-27; Ord. No. 2871, § 1, 7-5-2016; Ord. No. 2998, § 2, 11-15-2021)

Ask a question about Cedar Falls law

Corpus searches the Cedar Falls sections it holds and shows the ones that match, with their citations. Free, no sign-in.