29.55 - 605.2 Receptacles.
Section 605.2 of the IPMC is hereby amended by deleting said section and replacing it with the following: 605.2 Receptacles. Every habitable space in a dwelling shall contain not less than two separate and remote receptacle outlets. Every laundry sink and/or laundry area shall contain not less than one grounding-type receptacle or a receptacle with a ground fault circuit interrupter. Every existing or new bathroom shall contain at least one ground fault circuit interrupter protection type receptacle. All receptacle outlets shall have the appropriate faceplate cover for the location. Section 605.2.1 Ground fault. All receptacles located above and adjacent to work counters within 3 feet of a sink or water distribution fixture shall be ground fault circuit interrupter protection type. Section 605.2.2 Exterior GFCI. All exterior outlets must be ground fault circuit interrupter protection type with approved covers. Section 605.2.3 Tamper Resistant. All replacement outlets shall be of a tamper resistant type. (033-24)