§ 33.34 — Foundation Drainage Systems
Cedar Rapids, Iowa, Municipal Code (Supp. No. 25, Update 1: codified through Ordinance No. 025-26, passed July 28, 2026) · Cedar Rapids Municipal Code § 33.34
Corpus is an independent public-information project, not the official City of Cedar Rapids website. Stable reference: corpuslaw.us/code/19dba876-4087-431f-b3b6-02a8040b1d08
33.34 - Foundation Drainage Systems.
The Building Code is hereby amended by deleting Section 1805.4.3 of the International Building Code, 2024 Edition, and by replacing said section with a new Section 1805.4.3 and by adding a new Section R401.3.1 to the International Residential Code, 2024 Edition, as follows: Section 1805.4.3/R401.3.1 Drainage discharge. The floor base and foundation perimeter drain shall discharge by gravity or mechanical means into an approved drainage system that complies with the following: A sump pit must be located inside the building. EXCEPTION: If approved by the Building Official, the sump pit may be omitted if drainage tile can be designed with natural fall and drain on the same property. For each sump pump installed, a pump discharge pipe shall be connected to the appropriate approved storm sewer or other appropriate approved discharge location. If no approved storm sewer connection is available the discharge point shall discharge a minimum of two (2) feet from the outside foundation wall and no closer than 10 feet from the lot line. No sump discharge may cause a hazard. The pump discharge pipe shall be installed as per the requirements of the Plumbing Code with connections to the City storm sewer as per the Cedar Rapids Metropolitan Area Engineering Design Standards Manual. Installation of a sump pump, if one is found by the Building Official or designee to be necessary, shall include equipping the sump pump to automatically provide for discharge of sump pit water outside the basement wall and above grade and/or otherwise equipping the sump pump in a manner approved by the Building Official. A sump pump will be considered to be necessary if water inside the sump pit will not recede to a level four inches or more below the lowest basement floor surface by gravity or absorption into the earth within a reasonable period of time. Where ground water conditions warrant, the Building Official or designee may require additional drainage methods or engineering as he/she deems necessary. (005-26)
Ask a question about Cedar Rapids law
Corpus searches the Cedar Rapids sections it holds and shows the ones that match, with their citations. Free, no sign-in.