§ 102-329 — Development criteria
Municipal Code of the City of Des Moines, Iowa (Supp. No. 38, Update 3: codified through Ordinance No. 16,577, adopted August 24, 2026) · Des Moines Municipal Code § 102-329
Corpus is an independent public-information project, not the official City of Des Moines website. Stable reference: corpuslaw.us/code/ba770ff4-11e1-420e-beb4-5bb025cecbd3
Sec. 102-329. - Development criteria.
(a) There shall be at most one skywalk bridge per block face; provided, however, that a second skywalk bridge may be constructed in a block face if: (1) At least one of the blocks to be connected by such skywalk bridge has at least 1,500 persons regularly employed or residing within such block; (2) A property in such block to be connected to such skywalk bridge has at least 500 persons regularly employed or residing and does not have any other connection to the skywalk system shown on the skywalk system plan map; (3) Such skywalk bridge shall be connected to a skywalk corridor which is shown on the skywalk system plan map; and (4) There shall be a vertical access facility accessible from such skywalk bridge in each block connected by such skywalk bridge. (b) There shall be at least one vertical access facility in each block accessible to and usable by the handicapped. However, in the event two adjoining blocks are consolidated by the vacation of the intervening street and are occupied by single building, one vertical access facility may be used to serve the two consolidated blocks if two or more other vertical access facilities are also maintained in adjoining blocks at locations immediately accessible from a skywalk bridge connecting to the two consolidated blocks. A vertical access facility may utilize an existing vertical transfer system in a private property traversed by the skywalk system. (c) All doors in the public skywalk system shall be built entirely at private expense, except that doors at the end of a skywalk bridge connecting to city property or within city property shall be built at city expense. (d) The method of transfer between skywalk corridors in different buildings of different heights shall be accessible to and usable by handicapped persons. (e) The skywalk system shall be maintained free of all obstructions, except that sculpture, plantings, supports for public announcements or artworks or other amenities, as approved by the skywalk committee, may be erected in those portions of the nodal areas, skywalk corridors or skywalk bridges which exceed 14 feet in width and which have been dedicated for public skywalk purposes. Where a public utility contracts to provide public communication equipment and service in one or more such locations, the owner or lessee of such location shall be entitled to the proceeds from such contract. (f) Skywalk corridors shall conform to the following minimum design standards: (1) Width. Skywalk corridors shall have a minimum width of 14 feet free and clear of any obstructions or intrusions. However, in the following circumstances, the lesser widths specified may be allowed: a. Where a column, pipe or other integral structural feature or member of an existing building will intrude into a skywalk corridor, such corridor and the easement therefor shall be for that narrower width for the minimum distance which is necessary to prevent such intrusion. b. Where a skywalk corridor is constructed over an alley or vacated alley between existing buildings, and where a column, pipe or other integral structural feature or member of an existing building or buildings restrict the available width for construction of the skywalk corridor, such corridor and the easement therefor shall be of the maximum width that can reasonably be constructed, such reduced width shall be for the minimum distance possible, and no portion of the corridor shall be less than 13 feet free and clear of any obstructions or intrusions. c. Where the easement for a skywalk corridor is in a building corridor already constructed as of July 3, 1980, such skywalk corridor shall have a minimum width of 12 feet free and clear of any obstructions or intrusions. d. The city council in its discretion may accept a right to an easement for a skywalk corridor 14 feet in width and may restrict the actual width of the easement for a skywalk corridor to no less than 12 feet in those situations where on one side of the skywalk corridor any barricade wall or other physical barrier or obstruction, including but not limited to chainlink mesh, clear glass or other material, which stands or is erected or placed between such corridor and the abutting private property interest, meets all of the following criteria during the regular hours the building or business in which the skywalk corridor is located is open: 1. Such physical barrier or obstruction comprises no more than 40 percent of the area of the vertical plane between floor and ceiling running parallel to and at the edge of such corridor through such property interest. 2. In those open portions of such areas where such barrier does not extend from floor to ceiling, the private property interest may place or stand temporary obstructions within the 14-foot right to an easement area but without the 12-foot easement on the open side, so long as no such obstruction shall be placed or stood within the 14-foot right to an easement width which exceeds 36 inches in height measured from the floor and/or the ceiling; provided, however, that any such temporary obstruction affixed to the ceiling must not extend lower than seven feet above the floor. Where such open spaces exist on both sides of such corridor, such intrusion shall be limited to a total of two feet divided between the two sides of the corridor at the private property interest's discretion; provided, however, that the amount of intrusion on each side of the corridor shall be uniform for the length of such corridor through the private property. Doors which are normally closed but which open into a skywalk corridor shall not be deemed barriers, obstructions, or intrusions as referred to in this subsection. Doors that are provided for fire protection or for atmospheric pressure control with a total opening width of ten feet eight inches or more shall not be deemed barriers, obstructions or intrusions as referred to in this subsection. (2) Height. Skywalk corridors shall have a minimum height of nine feet or the existing ceiling height of the space through which the corridor is to pass, whichever is lower, free and clear of any obstructions or intrusions except at those points of the corridor where a beam, pipe or other similar structural feature of the existing building requires a lower height for that minimum distance necessary to pass such beam, pipe or other similar structural feature. (3) Delineation. Skywalk corridors shall be readily identifiable and distinguishable from the surrounding parts of the buildings through which they pass. The skywalk corridor may be delineated by different floor coverings, by walls or by physical barriers. (4) Lighting. There shall be artificial lighting capable of providing a minimum intensity at every point along the skywalk corridor floor of either: a. 30 footcandles; or b. an amount equivalent to the recommended illumination standards for Transition Spaces, Public, Independent Passageways (ages 65 and older), as identified in The Lighting Handbook, Tenth Edition (the "Lighting Handbook"), published by the Illuminating Engineering Society. Lighting controls intended to reduce artificial light output and conserve energy are acceptable as long as the recommended minimum standards in the Lighting Handbook are met. For new construction and reconstruction of existing skywalk lighting systems, the illumination shall meet the average/minimum uniformity ratios identified in the Lighting Handbook. Lighting fixtures shall be recessed in or attached in immediate proximity to the ceiling, except that hanging or pendant fixtures will be permitted which do not invade the minimum skywalk corridor height. If additional lighting fixtures must be provided, they shall be supplied with electricity in such a manner that the interruption of service in any circuit inside the building will not result in total interruption of the required lighting. (5) Heating and cooling. The skywalk corridor must be serviced by heating and cooling equipment capable of sustaining skywalk corridor temperatures between 65 degrees and 85 degrees Fahrenheit at all times. (6) Minimum clearance over alleys. Any skywalk corridor constructed over an alley shall have a minimum clearance over the surface of the alley of 14 feet six inches, unless a variance is granted in accordance with section 102-323 of this article which permits a lower minimum clearance over an alley. (g) The only signs that will be allowed in skywalk corridors and skywalk bridges are skywalk logos, skywalk map and route directories, skywalk directional signs and skywalk building identification signs as approved by the skywalk committee. The private property interests shall be allowed to erect store or building name signs and building directories on the sidewalls of skywalk corridors with approval by the skywalk committee and shall be allowed to erect any signs they wish on the private property adjacent to the skywalk corridors, so long as these signs are not so similar to skywalk graphics as to cause confusion. (h) Skywalk corridors shall conform to such minimum design standards for skywalk corridors as exist at the time the easement for the corridor comes into being. (i) Skywalk bridges shall have a minimum width of 14 feet and a minimum height of nine feet, both free and clear of any obstructions or intrusions; shall have a minimum clearance over the traveled portion of streets of 16 feet six inches and over the surface of alleys of 14 feet six inches, unless a variance is granted in accordance with subsection 102-323 of this article which permits a lower minimum clearance over an alley; and shall conform to such other minimum design standards as are adopted from time to time by the city council and kept on file in the city clerk's office. However, if the city council determines to incorporate into the skywalk system any skywalk bridges existing as of the effective date of the ordinance from which this article derives, such bridges need not meet the minimum standards of this subsection. Doors that are provided for fire protection or for atmospheric pressure control with a total opening width of ten feet eight inches or more shall not be deemed as obstructions or intrusions as referred to in this subsection. Such doors shall be located at the building face or within the building. One set of intermediate structural supports may be located not less than every 100 feet where necessary to avoid bridge spans exceeding 100 feet, and a clear opening width of at least 12 feet shall be provided at each support location, provided that the clear open width may be less than 14 feet for only that minimum distance necessary to provide such support, which minimum distance shall not exceed two feet measured parallel to the length of the bridge. (j) Structural foundations and supports for skywalk bridges shall be built outside the public right-of-way lines wherever possible. They shall be built at private expense, except for those structural foundations and supports on that end of a skywalk bridge which connects to a city-owned building. (k) Those skywalk bridges, skywalk corridors and vertical access facilities which are designated by the city council as fire exits or paths to fire exits must be open in accordance with the applicable city fire ordinances, as may be from time to time amended, and all fire prevention code requirements as to the construction of skywalk corridors to a point of access to the outside must be observed. Private property interests may not use skywalk bridges or skywalk corridors as fire exits without specific permission from the city council. (l) If there is no plan for a person's property to be traversed by the skywalk system, as shown by the skywalk system plan map, and if such person's property touches a property which is traversed by an existing portion of the skywalk system, such person may apply for connection to the skywalk system under section 102-326 of this article.
(C79, § 23-244; O.9781, 9854, 9900, 9982, 10,031, 10,052, 10,589, 10,666; C91, § 23-244; O.11,793, 13,910, 13,996, 14,045, 14,564, 15,178)
Ask a question about Des Moines law
Corpus searches the Des Moines sections it holds and shows the ones that match, with their citations. Free, no sign-in.
