Sec. 26-356. - Protection of openings onto the skywalk system which are located within 25 feet of property line.

Notwithstanding anything to the contrary contained in the International Building Code, openings onto the skywalk system which are located within 25 feet of the property line shall be protected as follows: (1) If two buildings are joined by a skywalk corridor constructed between such buildings: a. The centerline of the skywalk corridor easement shall be deemed the property line, and no opening shall be permitted in any wall of such skywalk corridor which is less than seven feet from the property line; b. Such skywalk corridor shall be protected by an approved automatic sprinkler system; c. Any wall of the skywalk corridor which is less than seven feet from the adjacent property line shall be of at least two-hour fire resistive construction; and d. Any openings in the skywalk corridor walls shall be either: 1. Of approved opening protective set in metal frames in accordance with the International Building Code, provided a draft curtain of at least one-hour fire resistive construction and not less than 12 inches in height shall be provided to protect the skywalk corridor from the adjacent building area, which draft curtain shall be located above the glass and extend a minimum of 12 inches below the lowest finished ceiling of either such adjacent building area or the skywalk corridor, or, if the finished ceiling is not a fire-rated assembly, the draft curtain shall extend from the opening protective to a rated ceiling or floor assembly; or 2. Protected in the following manner: i. The adjacent building area onto which such opening occurs is protected by an approved automatic sprinkler system; ii. A draft curtain of at least one-hour fire resistive construction and not less than 12 inches in height and including an approved water curtain of sprinkler heads six feet on center immediately adjacent to such draft curtain and above the opening within the building area shall be provided to protect the skywalk corridor from the adjacent building area, which draft curtain shall be located above the opening and shall extend a minimum of 12 inches below the lowest finished ceiling area of either such adjacent building area or the skywalk corridor or, if such finished ceiling is not a fire-rated assembly, the draft curtain shall extend from the opening to a rated ceiling or floor assembly; and iii. Either (i) the ceiling, walls and floor of the adjacent building area onto which such opening occurs shall be separated from the rest of such building by at least two-hour fire resistive construction and all duct penetrations in such building area shall be protected with fire dampers in accordance the International Building Code, or (ii) the entire story is protected by an approved automatic sprinkler. (2) If a skywalk corridor is constructed exterior to and attached to any one building, but is not between two or more buildings, and such skywalk corridor extends over the adjacent property line related to such building: a. The centerline of the skywalk corridor easement shall be deemed the property line, and no opening shall be permitted in any wall of such skywalk corridor which is less than seven feet from the property line; and b. 1. If the adjacent building is protected or is required to be protected by an approved automatic sprinkler system, such skywalk corridor shall be protected by an approved automatic sprinkler system; or 2. If the adjacent building does not have and is not required to be protected by an approved automatic sprinkler system, such skywalk corridor need not be provided with an approved automatic sprinkler system at the time of construction, provided that the property owners and/or lessees who are responsible for such skywalk corridor under a skywalk agreement with the city shall also agree in such skywalk agreement to provide an approved automatic sprinkler system if a second building is constructed within ten feet of such skywalk corridor; and c. Any wall of the skywalk corridor which is less than seven feet from the adjacent property line shall be of at least two-hour fire resistive construction; d. Any openings from such skywalk corridor into the adjacent building shall be in accordance with subsection (1)d of this section; and e. Any windows in the wall of such skywalk corridor opposite the building to which it is adjacent either: 1. Shall be of approved opening protective set in metal frames in accordance with section 716 of the International Building Code; or 2. May be of other glass, provided that the property owners and/or lessees who are responsible for such skywalk corridor under a skywalk agreement with the city shall also agree in such skywalk agreement to: i. Replace such glass with approved opening protective set in metal frames in accordance with the International Building Code if any building subsequently is constructed which is within ten feet, but not attached to, such skywalk corridor wall; and ii. Pay the equivalent of the cost of providing such approved opening protective towards the cost of reconstructing all openings in such skywalk corridor wall in accordance with subsection (1)d of this section if any building subsequently is constructed which is attached to such skywalk corridor wall. (3) Two buildings may be joined by a wall opening, provided: a. The wall opening shall be protected by a fire assembly having at least a 1½-hour fire protection rating; or b. The wall opening may be unprotected if the entire building on both sides of wall opening are protected by an approved automatic sprinkler system; and c. In either case, there is a draft curtain of at least two-hour fire resistive construction and not less than 12 inches in height, which draft curtain shall be located above the opening and shall extend a minimum of 12 inches below the lowest finished ceiling on either side of the wall opening, or, if the finished ceiling is not a fire-rated assembly on either side, the draft curtain shall extend from the opening to a rated ceiling or floor assembly on such side of the opening. (4) If two buildings are connected by a skywalk bridge: a. If such skywalk bridge is not connected to a skywalk corridor which is exterior to any building to which such skywalk bridge is connected, it shall be sufficient if the opening at one end of such skywalk bridge is protected by approved fire assemblies having at least a 1½-hour fire protection rating with gasketed frames, and the remaining construction where such end of the skywalk bridge penetrates the adjacent building is of at least two-hour fire rating construction; or b. If such skywalk bridge is connected to a skywalk corridor which is exterior to any building to which such skywalk bridge is connected, all openings from such skywalk bridge into the adjacent buildings shall conform to the requirements of subsection (1) of this section.

(O.15,861)