§ 14.24.040 — Amendments, modification, additions, and deletions

Municipal Code of the City of Fort Dodge, Iowa (Codified through Ordinance No. 2411, passed December 8, 2025. (Supp. No. 20)) · Fort Dodge Municipal Code § 14.24.040

Corpus is an independent public-information project, not the official City of Fort Dodge website. Stable reference: corpuslaw.us/code/e5397347-296a-43e9-886d-a755a5729264

14.24.040 - Amendments, modification, additions, and deletions.

The following amendments, modifications, additions and deletions to the National Electrical Code are made: (1) Services. (a) In all installations where there is more than one meter grouped, each meter shall be permanently identified. (b) All new services shall be a minimum of one hundred amperes, one hundred twenty to two hundred forty volts, unless approved by the enforcing authority before installation is made. Exceptions may be made for such services as, but not limited to, outdoor lighting, fixed loads and security systems. For multiple dwellings, the above-established minimum shall be applied per dwelling unit. (c) Overhead services shall be of rigid conduit, intermediate metallic tubing, electrical metallic tubing, or approved duct. (d) All new and replacement services on buildings shall have an intersystem bonding termination as described in NEC Sec. 250.94 located on the exterior of the structure on or in the immediate vicinity of the metering equipment enclosure. (2) Except as otherwise provided in this chapter, all electrical equipment installed, used or made available to the public shall be in conformity with the provisions of this chapter, and with approved electrical standards for safety to persons and property. Unless by this chapter a specific type or class of electrical equipment is disapproved for installation and use, conformity with the standards of Underwriter's Laboratories, Inc., or other nationally-recognized testing laboratory as approved by the American Standards Association is required. The electrical provisions of other standards approved by the American Standards Association shall be prima facie evidence of conformity with approved standards for safety to persons and property provided, however, that the provisions of this section shall not apply to equipment owned or used by an electric supply or communications agency in the generation, transmission or distribution of electricity or for the operation of signals for the transmission of intelligence. (3) All references in the aforesaid 2020 National Electric Code or current state code shall be deemed a reference to the building code currently adopted by the city of Fort Dodge.

(Ord. No. 2407, 7-14-25)

Ask a question about Fort Dodge law

Corpus searches the Fort Dodge sections it holds and shows the ones that match, with their citations. Free, no sign-in.