9-9-23: IECC ENERGY CODE AMENDMENT, TABLE R402.1.2, INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT:

Repeal the row in Table R402.1.2 for climate zones "5 and Marine 4" and replace with the following: TABLE R402.1.2 INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENTa, j Climate Zone | Fenestration U-Factorb | Sky lightb U-Factor | Glazed Fenestration SHGC b,e | Ceiling R-Value | Wood Frame Wall R-Value | Mass Wall R-Valuei | Floor R-Value | Basementc Wall R-Value | Slabd R-Value & Depth | Crawl-Spacec Wall R-Value 5 | 0.3 2 | 0.5 5 | NR | 38 | 20 or 13+ 5h | 13/17 | 30g | 15/19 | 10, 2 ft | 15/19 Footnotes published underneath Table R402.1.2 in the code are applicable. (Ord. 42-20, 12-1-2020, eff. 1-1-2021; Ord. 4-25, 2-4-2025)