For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 32-45 — Required improvements

Code of Ordinances of the City of Lewiston, Idaho (Codified through Ordinance No. 4973, enacted July 27, 2026. (Supp. No. 11)) · Lewiston Code of Ordinances § 32-45

Corpus is an independent public-information project, not the official City of Lewiston website. Stable reference: corpuslaw.us/code/c44a0529-b327-4dfb-bb7c-00176f0c553c

Sec. 32-45. - Required improvements.

The subdivider shall design and construct all improvements in conformance with adopted city standards and codes. Should unique conditions exist such that these standards cannot reasonably be met, the subdivider may petition the council for amendments to the specific standard. Said request for amendment shall be accompanied by an engineering report which identifies the standard proposed and the reasons justifying such request. The subdivider is responsible for the design and installation of the following improvements: (a) Streets and alleys. All streets and alleys within the subdivision shall be graded and surfaced to cross-sections, grades and standards approved by the city engineer. Where there are existing streets adjacent to the subdivision, subdivision streets shall be improved, and, if necessary, feathered to the center of such existing streets. Dead-end streets serving more than four (4) lots shall be provided a graded and surfaced temporary turning circle. A traffic report may be required to document the traffic impacts of the subdivision; the subdivider shall be responsible for the installation of both off-site and on-site improvements recommended in the traffic report. (b) Curbs. Portland cement concrete curb and gutter or roll curb, as designated by the city engineer, shall be installed in accordance with approved city standards. (c) Sidewalks. Portland cement concrete sidewalks shall be required on all streets in all zones. They shall be constructed to a width, line, and grade approved by the city engineer in accordance with approved city standards. Where unique topographical characteristics exist and the installation of sidewalks is not practical, the commission may recommend that certain portions of sidewalks within the subdivision be waived. (d) Pedestrian and bicycle ways. Pedestrian and bicycle ways shall be constructed to a line and grade approved by the city engineer. Paving, fencing, and/or landscaping may be required by the commission as recommended by the subdivision committee. Appropriate means shall be provided to prevent the use of the pedestrian ways as thoroughfares for bicycles and motorcycles. (e) Storm drainage. Proper and adequate provision shall be made for disposal of storm waters; this shall apply equally to grading of private properties and to public streets. Existing watercourses shall be maintained and dedicated as drainage ways. The type, extents, location, and capacity of drainage facilities shall be determined for the individual subdivision by the engineer for approval by the city engineer and shall be constructed in accordance with approved city standards. (f) Sanitary sewage disposal. Sewage disposal facilities shall be installed to serve each lot and shall be subject to the following standards and approvals: (1) Individual systems may be constructed only in areas not reasonably accessible to a public sewer system, and then, only when the following conditions are met, to the satisfaction of the state department of health and welfare and subject to the approval of the public works administrator: a. Soil absorptivity is adequate for drainfields. b. Construction complies with approved standards for sewerage systems. c. Location of septic tanks and seepage pits or leach lines or disposal beds in relation to property lines, buildings, water supply wells and water lines are acceptable to the department. Location shall be such that efficient and economical connection can be made to a future public sewer. d. Lots of one (1) acre and larger. (2) Public sanitary sewers shall be installed in areas which are reasonably accessible to an existing sewer system and shall be constructed to plans, profiles, and specifications approved by the state department of health and welfare and city departments having jurisdiction. (3) In areas where public sanitary sewers are not reasonably accessible, but where the city, or independent sewer district having jurisdiction, agrees to provide temporary disposal of sewage, or where an engineering design for a sewer system for the area in which the subdivision is located has been adopted by the city, the subdivider shall plan and construct sewers within and for the subdivision for connection with a future public system. (g) Water supply. Each lot shall be supplied with potable water in sufficient volume and pressure for domestic use and adequate water, in pressure and volume, for fire protection, in accordance with city standards. (h) Monuments. Permanent monuments shall be installed in accordance with current city standards at all corners, angle points, points of curve, and at all intersections. After all improvements have been installed, an Idaho registered land surveyor shall check the location of monuments and certify their accuracy and conformance to Idaho Code § 50-1303. (i) Lot corners. Iron pipe or pins shall be set at all corners, angle points, and points of curve for each lot within the subdivision prior to the recording of the plat in conformance with Idaho Code § 50-1303. (j) Utilities. (1) The subdivider shall be responsible for the requirements of this section and shall make the necessary arrangements with each of the serving utility companies involved for the installation of underground utilities. Letters from each of the serving utility companies indicating that such arrangements have been made shall be submitted to the city engineer at the time the final plat is submitted for approval. (2) New utility lines, including, but not limited to, electric, communication, and television transmission lines, shall be installed underground in accordance with the standards of the current edition of the National Electric Safety Code. When facilities are installed in the public right-of-way, the location shall be approved by the city engineer. (3) When overhead utility lines exist within the property being platted, said existing lines shall be removed and replaced by new underground installations. (4) When overhead utility lines exist on the periphery of the property being platted, said existing lines and any additions or improvements needed to increase capacity or improve service reliability may remain overhead. New service drops from said overhead lines into the platted area shall be placed underground. (5) When, as a result of the subdivision development, it is necessary to relocate, renew, or expand existing facilities within the platted area, the subdivider shall arrange with the serving utility for the installations to be placed underground. (6) The subdivider shall arrange with the serving utility for, and be responsible for the cost of, underground service lines to approved street light locations a specified in subsection (k) of this section. (7) When, due to subsurface soil conditions, rock, and/or other special conditions, it is determined by the city engineer that it is impractical to construct facilities underground, the planning and zoning commission may recommend approval of the overhead installation of facilities. (8) Those electrical transmission lines of greater than three thousand (3,000) kva (kilovolt-amperes), as rated by the American Standards Association, are excluded from the requirements of this section. (k) Street lights. (1) In all subdivisions or commercial or industrial developments, street lights and their required electrical service lines shall be installed as directed by the public works administrator. The street light type, size and locations shall be indicated on the approved construction plans and specifications. All fixtures, poles, conduit and other facilities shall meet the specifications and standards of the utility providing service. (2) If required, the developer will reimburse the city for all installation costs and monthly street light service fees in accordance with the current utility provider fee schedule and the subdivision improvement agreement, until such time as the subdivision or development is approved and accepted by the city council. (3) Once the subdivision or development has been approved and accepted by the city council, the monthly street light service cost will be borne by the city.

(Ord. No. 4177, § 1, 2-10-97)

Ask a question about Lewiston law

Corpus searches the Lewiston sections it holds and shows the ones that match, with their citations. Free, no sign-in.