§ 36-154 — Limitations on wastewater strength
Code of Ordinances of the City of Lewiston, Idaho (Codified through Ordinance No. 4973, enacted July 27, 2026. (Supp. No. 11)) · Lewiston Code of Ordinances § 36-154
Corpus is an independent public-information project, not the official City of Lewiston website. Stable reference: corpuslaw.us/code/f7bb0c39-2b1c-4d27-b6a8-a68f3fe4d761
Sec. 36-154. - Limitations on wastewater strength.
(a) National categorical pretreatment standards. National categorical pretreatment standards and other applicable regulations now existing or as hereafter promulgated by the USEPA, pursuant to the Act and as adopted, shall be enforceable by this division and shall be met by all dischargers of the regulated industrial categories. An application for modification of the national categorical pretreatment standards may be considered for submittal to IDEQ by the city when the city's wastewater treatment system achieves consistent removal of the pollutants, as defined by 40 CFR 403.7. (b) State requirements. State requirements and limitations on discharges to the POTW shall be met by all dischargers which are subject to such standards in any instance in which they are more stringent than federal requirements and limitations or those in this division or any other applicable ordinance. (c) Right of revision. The city reserves the right to amend this division or individual wastewater discharge permits to provide for more stringent limitations or requirements on discharges to the POTW where deemed necessary to comply with the objectives set forth in section 36-151 of this Code. (d) Dilution. No discharger shall increase the use of potable or process water in any way for the purpose of diluting a discharge as a partial or complete substitute for adequate treatment to achieve compliance with the applicable standards set forth in this division. The city may impose mass limitations on dischargers which are using dilutions to meet the applicable pretreatment standards or requirements of this chapter, or in other cases deemed appropriate by the city. (e) Local limits. In addition to the categorical pretreatment standards referenced in subsection (1) of this section, no discharger shall discharge wastewater containing concentrations of substances exceeding the following local limits: Parameter | Maximum Daily Concentration (mg/l) Arsenic | 0.10 Cadmium | 0.09 Chromium (total) | 4.31 Copper | 1.43 Cyanide | 0.50 Lead | 0.54 Mercury | 0.01 Nickel | 0.74 Silver | 0.09 Zinc | 2.78 All concentrations for metallic substances are for "total" metal unless indicated otherwise. The utility systems manager may impose mass limitations in addition to, or in place of, the concentration-based limitations above. Local limits shall apply to process wastewater after pretreatment, and/or prior to mixing with sanitary wastewater or other dilution flows. Wherever a discharger is subject to both a categorical pretreatment standard and a local limit for a given pollutant, the more stringent shall apply. BMPs established by the city are considered pretreatment standards and are fully enforceable as such under this division. (f) Pretreatment. Dischargers shall provide necessary wastewater pretreatment as required to comply with this division and shall achieve compliance with all applicable pretreatment standards within the time limitations as specified by appropriate statutes, regulation and ordinance. Any facilities required to pretreat wastewater to a level acceptable to the city shall be provided, properly operated and maintained at the discharger's expense. Detailed plans showing the pretreatment facilities shall be submitted to the city for review and must be acceptable to the city before construction of the facility. The review of such plans shall in no way relieve the discharger from the responsibility of modifying its facility or operations as necessary to produce an effluent acceptable to the city under the provisions of this division. Within a reasonable time after the completion of the wastewater pretreatment facility, the discharger shall furnish its operations and maintenance procedures for the city to review. Any subsequent significant changes in the pretreatment facilities or method of operation shall be reported to and be accepted by the city prior to the discharger's initiation of the changes. (g) Special agreement. The city reserves the right to enter into special agreements with dischargers setting out special terms under which they may discharge to the POTW. In no case will a special agreement waive compliance with a categorical pretreatment standard or federal pretreatment requirement. However, the discharger may request a net gross adjustment to a categorical standard in accordance with 40 CFR 403.15. They may also request a variance from the categorical pretreatment standard from the approval authority in accordance with 40 CFR 403.13.
(Ord. No. 3611, § 2(3.02), 3-8-82; Ord. No. 3938, § 3, 2-13-89; Ord. No. 4048, § 4, 11-2-92; Ord. No. 4485, § 1, 6-23-08; Ord. No. 4603, § 3, 9-23-13; Ord. No. 4754, § 1, 7-8-19; Ord. No. 4746, § 4, 5-13-19; Ord. No. 4754, § 1, 6-9-19)
Ask a question about Lewiston law
Corpus searches the Lewiston sections it holds and shows the ones that match, with their citations. Free, no sign-in.
