Sec. 36-56. - Cross-connections.
(a) Responsibility of city. The City of Lewiston has the primary responsibility to protect the city-owned potable water system from actual and potential contamination by objectionable and hazardous liquids, solids and gases. The city's responsibility includes the total water system and extends from the source of supply to the point of delivery to the consumer's water system. It is also the city's responsibility to ensure that the consumer has taken proper steps to protect the city's potable water system from actual and potential contamination from the consumer's water system. (b) Prohibited. Except as approved by the state department of health of the State of Idaho, hereinafter referred to as the health department, all cross-connections as herein defined, whether or not cross-connections are controlled by automatic devices such as check valves or by hand-operated mechanisms, such as gate valves or stopcocks, are hereby prohibited. (c) Definitions. For the purpose of this regulation, cross-connections are defined as follows: (1) Any bypass, being defined as any physical arrangement whereby water may be diverted around any feature of the purification process of the city. (2) Any emergency intake or secondary intake being defined as an intake or other device capable of introducing water into the public water system from a source of supply which, because of its unsafe characteristics, has not been approved for drinking and culinary purposes by the health department. (3) Any other cross-connection as defined in the Manual of Cross-Connection Control published by the Foundation for Cross-Connection Control Research, University of Southern California, current edition. a. A cross-connection is a point in a plumbing system where the potable water supply is connected directly or can be connected directly to a nonpotable source. b. Air gap separation means the vertical physical separation between a supply line and the overflow rim of a receiving vessel. This separation must be at least twice the inside diameter of the supply line, but never less than one (1) inch. c. Auxiliary supply means any water source or system, other than the public water supply, that may be available in the building or premises. d. Backflow means the flow other than the intended direction of flow, of any foreign liquids, gases, or substances into the distribution system of a public water supply. e. Back pressure means backflow caused by a pump, elevated tank, boiler, or other means that could create pressure within the system greater than the supply pressure. f. Back siphonage means a form of backflow due to a negative or sub-atmospheric pressure within a water system. g. Backflow prevention assembly means an assembly to counteract back pressures or prevent back siphonage. h. Double-check valve assembly means an assembly composed of two (2) single, independently acting check valves, including tightly closing shutoff valves located at each end of the assembly and suitable connections for testing the water tightness of each check valve. i. Reduced-pressure principal backflow prevention assembly means an assembly incorporating two (2) or more check valves and an automatically operating differential relief valve located between the two (2) checks, two (2) shutoff valves, and equipped with necessary appurtenances for testing. j. A water purveyor is the owner or operator of the public potable water system supplying water for public use. k. Approved means approved in writing by the Department of Health and Welfare, Department of Environmental Quality or other agency having jurisdiction. l. Atmospheric vacuum breaker (AVB) means an assembly which contains a float check (poppet), a check seat, and an air inlet port. When water pressure is reduced to gauge pressure of zero (0) or below, air enters the device preventing back siphonage. An atmospheric vacuum breaker is designed to protect against back siphonage only. m. Pressure vacuum breaker (PVB) means an assembly consisting of a spring-loaded check valve (three (3) inches and larger consisting of two (2)), an independently operating air inlet valve, inlet and outlet shutoff valves and properly installed test cocks. The air inlet valve is internally loaded to the open position, normally by the means of a spring. This internal loading allows the device to be installed on the pressure side of a shutoff valve. It is designed to protect against back siphonage only. n. Internally loaded check valve means a check valve, which is internally loaded, either weighted or spring loaded, to the extent it will be drip tight in the direction of flow with a one (1) psi differential. (4) The provisions of this section shall apply to all existing and all new construction utilizing the city's water system. (d) Inspection. (1) The city shall review all water service connections and evaluate the degree of hazard and the type of protection needed to comply with the requirements of the State of Idaho Rules for Public Drinking Water Systems (Section 58.01.08). Where potential or actual cross-connections exist, the city shall notify the water consumer of the type of backflow prevention assembly that must be installed to provide adequate protection to the city's water system. The consumer shall proceed with the installation of the assembly at the location recommended by the city. When possible, the assembly shall be installed at the point of service delivery. A State of Idaho-certified backflow assembly tester shall test all backflow prevention assemblies a minimum of one (1) time each twelve (12) months. A list of approved certified backflow assembly testers will be available through the public works department. When a defective assembly is discovered, the consumer shall repair the defective assembly within time limits specified by the city. The tester shall be responsible for the accuracy of all tests and reports prepared by the tester. The water division must receive a copy of all test reports within ten (10) days of the final test, and a "TAG" containing the tester's name and date of satisfactory test shall be attached to the assembly. Any backflow prevention assembly left in a failed (nonpassing) condition, creating a potential threat to the potable water supply, must be reported to the water division within twenty-four (24) hours. The registration issued to any assembly tested may be revoked or suspended by the water division for improper testing or reporting. A report sheet shall be filled out and completed by the certified backflow assembly tester after each test and upon completion of any repairs. Each test result shall be submitted to the city. A report sheet shall be filled out and completed by the certified backflow assembly tester after installation, upon completion of any repairs, and annually. Test reports shall be sent to the city cross-connection control specialist. An old assembly no longer on the lists will be accepted, as long as it passes its annual test or can be repaired to pass the annual test. (2) No underground sprinkling device will be installed without an approved backflow prevention assembly at the point at which the water for irrigation is taken from the domestic water system. Atmospheric vacuum breakers will not be approved for this type of installation. Where there may be a separate system for irrigation purposes, it should never enter the consumer's residence or structure. Said system should terminate at least two (2) feet outside the residence or structure. (3) An approved backflow prevention assembly shall be installed on each service line to a customer's water system at or near the property line or immediately inside the building being served; but in all cases, before the first branch line leading off the service line wherever the following conditions exist: a. In the case of premises having an auxiliary water supply that is not or may not be of safe bacteriological or chemical quality and that is not acceptable as an additional source by the health department, the public water system shall be protected against backflow from the premises by installing an approved backflow prevention assembly in the service line, appropriate to the degree of hazard. b. In the case of premises on which any industrial fluids or any other objectionable substances are handled in such a fashion as to create an actual or potential hazard to the public water system, the public system shall be protected against backflow from the premises by installing an approved backflow prevention assembly in the service line, appropriate to the degree of hazard. This shall include the handling of process waters and waters originating from the utility system that have been subject to deterioration in quality. c. In the case of premises having (1) internal cross-connections that cannot be permanently corrected and controlled, or (2) intricate plumbing and piping arrangements or where entry to all portions of the premises is not readily accessible for inspection purposes, making it impracticable or impossible to ascertain whether or not dangerous cross-connections exist, the public water system shall be protected against backflow from the premises by installing an approved backflow prevention assembly in the service line. (4) The type of protective assembly required under subsections (3)(a), (b), and (c) of this section shall depend upon the degree of hazard that exists as follows: a. In the case of any premises where there is an auxiliary water supply as stated in subsection (3)(a) of this section and is not subject to any of the following rules, the public water system will be protected by an approved air-gap separation of an approved reduced-pressure principal backflow prevention assembly. b. In the case of any premises where there is water or substance that would be objectionable but not hazardous to health if introduced into the public water system, the public water system shall be protected by an approved double-check valve assembly. c. In the case of any premises where there is any material dangerous to health that is handled in such a fashion as to create an actual or potential hazard to the public water system, the public water system shall be protected by an approved air-gap separation or an approved reduced-pressure principal backflow prevention assembly. Examples of premises where these conditions will exist include sewage treatment plants, sewage pumping stations, chemical manufacturing plants, hospitals, mortuaries and plating plants. d. In the case of any premises where there are "uncontrolled" cross-connections, either actual or potential, the public water system shall be protected by an approved air-gap separation or an approved reduced-pressure principal backflow prevention assembly at the service connection. e. In the case of any premises where, because of security requirements or other prohibitions or restrictions, it is impossible or impractical to make a complete in-plant cross-connection survey, the public water system shall be protected against backflow from the premises by either an approved air-gap separation or an approved reduced-pressure principal backflow prevention assembly for each service to the premises. f. In the case of any premises where, in the opinion of the water division, an undue health threat is posed because of the presence of extremely toxic substances, the water division may require an air-gap at the service connection to protect the public water system. This requirement will be at the discretion of the water division and is dependent on the degree of hazard. (5) Existing structures. Annual inspections shall be made of all buildings, structures or improvements of any nature, now receiving water through the city's system for the purpose of ascertaining whether any cross-connections exist. Such inspections shall be on a continuing, rotating basis and shall be made by city authorized personnel certified by the Idaho Bureau of Occupational Licenses or the Health Department. Such inspections shall be for the purpose of establishing the water uses on the premises, the existence of any possible cross-connections, the availability of pollutants, contaminants and other liquid, solid or gaseous substances which may be used industrially for stabilization of water supplies, and may also include such other inspections and/or processes as are necessary for determining whether a health hazard exists upon the premises. (6) Representatives of the state health department or the U.S. Public Health Service or Idaho DEQ or EPA shall have the right to accompany city personnel on any inspection and may request inspections or may reinspect as they may deem necessary. (7) The city water system may be required to be protected by either a double-check valve assembly or a reduced-pressure principal backflow prevention assembly whenever a consumer's water system incorporates only atmospheric vacuum breakers to prevent back siphonage. (e) Correction, reinspection. If the city determines that by reason of a cross-connection a health hazard exists upon any premises inspected, the same shall be corrected by the landowner, at the landowner's expense. The city has the right to direct the landowner as to a minimum acceptable procedure for correcting the situation. Standards shall be based upon the latest edition of the Cross-Connection Control Manual, Accepted Procedures and Practice. The time limit as to the installation of a newly required assembly will be dependent upon the degree of health hazard that is present to the city's water supply. The higher the hazard, the shorter the time limits. The representative of the city, in cooperation with the Idaho State Health Department, shall determine a reasonable time within which the property owner shall complete such correction and shall reinspect the premises after the expiration of such period of time. (f) Penalties. If the department of public works determines that a parcel or lot within the city has an improper cross-connection, the director shall provide notice to the property owner that the cross-connection problem must be remedied and give the owner time to correct the problem. If the owner refuses to allow department personnel access to the property to assess the extent of the problem or if the owner refuses to timely correct the problem, the director may shut off water to the parcel or lot and all premises on that land in accordance with section 36-51(e) of this article. Water service shall be restored in accordance with section 36-66 of this article. (1) When an assembly has been required and installed and tested, it is not to be removed or tampered with in any way except by an authorized plumber with prior approval by the city's authorized personnel. Any violation shall be a misdemeanor and punishable as follows: First violation: $500.00 fine. Second violation: $750.00 fine and possible jail (three-month sentence). Third violation: $1,000.00 fine and possible jail (six-month sentence). Any violation will result in immediate termination of water service. Water service shall be restored in accordance with section 36-66 of this article. (2) Assemblies that have been installed on lawn sprinkling or irrigation systems for the purpose of protecting the domestic water supply may be tested by a certified backflow prevention assembly tester with the original copy of the form results being sent to the city. These assemblies are to be tested annually, preferably prior to the irrigation or sprinkling season. Faulty assemblies will be required to be corrected within seven (7) days of the failed test. Anyone who files a fraudulent form or fails to perform the physical test shall be assessed a civil penalty as follows: First violation: $500.00. Second violation: $750.00. Third violation: $1,000.00. (g) Attorney's fees. In the event it shall become necessary for the city to incur any attorney fees or court costs in order to enforce the provisions of this section concerning cross-connections, the amount of such fees and costs shall be paid by the property owner before water service is restored to the premises. (h) Installation. Whereas it is deemed necessary for a reduced-pressure backflow assembly (RPBA) to be installed for protection of the public system, said assembly shall never be placed below ground level or in a vault/pit or other structure except with these minimum requirements: (1) Twelve (12) inches plus the nominal diameter of the assembly clearance below the assembly. (2) Area is able to be drained to daylight, with a line at least twice the size of the assembly. (3) Drain line to be unrestricted in flow characteristics. Drain line is to have magnetic door to prevent rodents from entering and to prevent plugs from occurring. (4) Will not be subjected to flood conditions/submerged. (5) At least twelve (12) inches' clearance from the walls of the vault or structure. (6) Access to the area of the assembly by an authorized employee of the city is unrestricted and attainable (e.g., not covered in any way for beautification's sake).
(Code 1960, § 36-74.1; Ord. No. 3011, §§ 1 - 4, 2-8-71; Ord. No. 3788, § 30, 6-24-85; Ord. No. 4039, § 2, 4-20-92; Ord. No. 4080, § 32, 8-30-93; Ord. No. 4485, § 1, 6-23-08; Ord. No. 4603, § 3, 9-23-13; Ord. No. 4840, § 9, 5-23-22)
Ask a question about Lewiston law
Corpus searches the Lewiston sections it holds and shows the ones that match, with their citations. Free, no sign-in.