For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 37-149.1 — Drive-thru service facilities

Code of Ordinances of the City of Lewiston, Idaho (Codified through Ordinance No. 4973, enacted July 27, 2026. (Supp. No. 11)) · Lewiston Code of Ordinances § 37-149.1

Corpus is an independent public-information project, not the official City of Lewiston website. Stable reference: corpuslaw.us/code/3446eb38-e00b-4217-abdc-dccd04e6c1f3

Sec. 37-149.1. - Drive-thru service facilities.

(a) Number of car queue spaces required. The minimum number of car queue spaces for drive-thru service facilities shall be as follows, unless otherwise justified by a trip generation and site design study performed by a traffic engineer licensed in the State of Idaho specific to the proposed drive-thru service facility and accepted by the city engineer: (1) Eating and drinking establishments that have an ordering station separate from the pick-up window: nine (9) spaces total with at least four (4) spaces from the pick-up window to the ordering station; or, if two (2) ordering stations in different lanes merge into a single pick-up window lane, then eleven (11) spaces total with at least five (5) spaces from the pick-up window to the ordering station and at least three (3) spaces per ordering station. (2) Eating and drinking establishments without an ordering station separate from the pick-up window and where ordering, payment, and pick-up are done at the same service window: five (5) spaces for a one (1) window facility or four (4) spaces per window for two (2) service windows. (3) Car washes: four (4) spaces for a single bay automated system; or two (2) spaces per bay for a multiple bay automated system; or one (1) space per bay if the car wash is a non-automated system whereby the driver gets out of the vehicle to wash the vehicle in the wash bay. (4) Pharmacies: four (4) spaces. (5) Banks and automated teller machines: three (3) spaces per service station; or, if more than one (1) non-tandem service station (i.e., multiple service station lanes), then two (2) spaces per service station. (6) Gas pumps: one (1) space from each end of each pump island. (7) Other: For other types of drive-thru service facilities not included in a category listed above, the minimum number of car queue spaces shall be four (4). (8) A minimum of two (2) car queue spaces shall be required for the exiting of a drive-thru service facility, as measured from the forward end of the final point of service to any point of anticipated traffic stoppage, such as the intersection of the drive-thru exit lane with another queue lane or with a driveway exit from the property. This minimum number of exit car queue spaces may be increased, as determined by the city engineer, based upon the design and traffic flow conditions specific to the site. (b) Design standards and requirements. Drive-thru service facilities shall comply with the following design standards and requirements: (1) Minimum car queue space length: twenty (20) feet per space. (2) Minimum drive-thru lane and car queue space width: ten (10) feet. (3) Minimum drive-thru lane inside turn radius: twenty (20) feet. (4) Minimum buffer (not required for gas pumps): a. Each drive-thru service facility shall provide a five-foot wide minimum irrigated landscape strip planted with a minimum of one (1) one-and-one-half (1.5) inch diameter caliper shade tree and five (5) shrubs every thirty-five (35) feet along its street frontage(s). b. Each drive-thru facility shall provide at least one (1) of the following buffers between the drive-thru lane, including all minimum required car queue spaces and the required two (2) exit car queue spaces, and an adjoining property: 1. Fifteen-foot minimum distance between outside line of drive-thru lane and property line; 2. A six-foot tall minimum sight obscuring fence (no chain link with slats) or wall; provided, that it shall not cause a vehicular or pedestrian traffic hazard due to interference with sight distance triangles; 3. A five-foot wide minimum irrigated landscape strip planted with a minimum of one (1) one-and-one-half (1.5) inch diameter caliper shade tree and five (5) shrubs every twenty-five (25) feet; provided, that the plantings shall not cause a vehicular or pedestrian traffic hazard due to interference with sight distance triangles; 4. Any combination of reduced versions of the buffers listed above, if the community development director determines it provides equal or greater benefit than the individual buffers listed above. (5) Car queue space measurement shall begin from the forward end of the car queue space located at the point of service. (6) Drive-thru lanes, including all minimum required car queue spaces and the two (2) required exit car queue spaces, shall be paved. (7) Drive-thru lanes shall not be located within a public right-of-way, required parking stall access maneuvering area, or drive aisle. (8) Drive-thru lanes shall be clearly demarcated with striping or curbing. (9) If a drive-thru lane is located between a building entrance and parking spaces for the building, a minimum four-foot wide pedestrian crossing shall be striped across the drive-thru lane directly in front of the building entrance. The pedestrian crossing shall be clearly identified as such and include a "KEEP CLEAR" or "DO NOT BLOCK" sign or message. The width of the pedestrian crossing shall not count toward the minimum required car queue space length for the drive-thru service facility. (10) If provided as part of a drive-thru service facility, an ordering station using a speaker system shall not be located less than ten (10) feet from a residential property without a noise attenuation wall designed to ensure compliance with chapter 24, article II of this Code (Noise Control Regulations). (11) Site plans showing compliance with the requirements for drive-thru service facilities set forth herein shall be prepared by a design professional licensed in the State of Idaho. (12) Operation of a drive-thru service facility shall only be permitted when ingress and egress to and from a public right-of-way does not generate conflicting turning movements or traffic congestion deemed hazardous by the city engineer. The city engineer may deny an application for a drive-thru service facility or impose limitations as necessary to prevent any such hazardous turning movements or traffic congestion. (13) Applicants proposing a car wash shall provide a written statement on the site plan for the building permit application documenting the following: a. The proposed car wash and any associated vacuuming service facilities, based upon the particular equipment and site design proposed, will comply with chapter 24, article II of this Code (Noise Control Regulations), and that if a noise violation is found by the city, the property owner will be responsible for implementing measures as necessary to abate the noise violation; and b. Based upon the particular car wash and site design proposed, spray that may exit the car wash will not cause a nuisance, and that if said spray is determined by the city to be a nuisance, the property owner will be responsible for implementing measures as necessary to abate the nuisance.

(Ord. No. 4671, § 2, 10-24-16)

Ask a question about Lewiston law

Corpus searches the Lewiston sections it holds and shows the ones that match, with their citations. Free, no sign-in.