§ 37-93.D — Building form and orientation standards
Code of Ordinances of the City of Lewiston, Idaho (Codified through Ordinance No. 4973, enacted July 27, 2026. (Supp. No. 11)) · Lewiston Code of Ordinances § 37-93.D
Corpus is an independent public-information project, not the official City of Lewiston website. Stable reference: corpuslaw.us/code/66601fdc-9e54-4a9a-aad0-654b649e5f26
Sec. 37-93.D. - Building form and orientation standards.
(a) The construction of a new building in the FIB Zone, other than an accessory building, or the reconstruction of an existing building in the FIB Zone, other than an accessory building, shall comply with the building form and orientation standards contained in this section, except that: (1) Development proposals that generate a minimum of one and one-half (1½) times the minimum point threshold required by section 37-93.E of this Code shall be exempted from the floor area ratio standard; and (2) Development proposals that generate a minimum of one and one-third (1⅓) times the minimum point threshold required by section 37-93.E of this Code shall be exempted from any one (1) of the building form and orientation standards of the developer's choosing, except the building height or floor area ratio standard. (b) For purposes of this section, reconstruction of an existing building shall mean work that exceeds eighty (80) percent of the building value, as determined by one (1) of the following options chosen by the building owner: (1) The assessed value, as determined and on file at the Nez Perce County Assessor's office on the date of a building permit application; (2) The appraised value, as determined by an appraiser licensed by the Idaho Real Estate Appraiser Board Bureau of Occupational Licenses, within not more than one (1) year from the date of a building permit application filed after October 27, 2018; or (3) Sixty-five (65) percent of the value used to determine a building permit fee to reconstruct the building based upon the most recently adopted International Building Code, as determined by the City of Lewiston building official. (c) Standards. (1) Building height. Height allowance: Eighty-four (84) feet maximum, not counting any parapet of three (3) feet in height or less and not counting any architectural appurtenance exempted from maximum allowable building height, pursuant to section 37-159 of this Code; or a maximum of eight (8) stories, as determined by the City of Lewiston building official based upon the International Building Code. (2) Floor area ratio (FAR). FAR: 0.5 to 1.0, which means that the total building gross floor area shall be equal to at least fifty (50) percent of lot square footage. Any roof-top parking or roof-top patio shall be included in the FAR calculation, and basements designed for occupancy or a parking garage shall also be included in the FAR calculation. Faux or false stories shall not be included in the FAR calculation. This FAR standard shall not apply to a commercial entertainment facility. (3) Building location relative to Levee Bypass Road right-of-way line. Ten (10) feet minimum. (4) Building location relative to a street right-of-way line other than Levee Bypass Road: Ten (10) feet maximum at first floor level, except for a hotel as specified below. For a lot having more than one (1) street frontage, the building shall be located a maximum of ten (10) feet from at least one (1) of the street frontages. Upper floors (those above the first floor) each may be set back not more than an additional five (5) feet per floor or per fourteen (14) feet of building height above the first floor, whichever yields the greater setback, unless such upper floor additional setback is to accommodate an outdoor terrace that extends to the required setback for that floor level. If the space between the first floor of the building and street right-of-way line is used for outdoor dining, gathering, or other improved open space that is designed for access and use by the public, occupants, or patrons of the building, then the building may be set back a maximum of twenty (20) feet from the street right-of-way line. A hotel building shall not be located farther than fifteen (15) feet from a street right-of-way line, unless: (a) the lot has multiple street frontages and the hotel building maintains the fifteen (15) feet maximum setback from at least one (1) street frontage; or (b) it is for purposes of accommodating a porte-cochere for loading/unloading guests of the hotel. If the hotel building is set back farther than fifteen (15) feet from the street right-of-way line to accommodate a porte-cochere, then the hotel building shall be attached to the porte-cochere, and the porte-cochere shall not be set back from the street right-of-way line farther than twelve (12) feet. Upper floor levels of a hotel building may be set back farther from the street right-of-way line than the first floor at a ratio not to exceed ten (10) feet of additional setback per floor level greater than one (1). (5) Building access. Location, design, and orientation of building access. Building walls facing streets shall contain at least one (1) public, architecturally defined pedestrian building entrance. Such entrance shall be designed and oriented so as to be clearly identifiable from the street and sidewalk as a public pedestrian entrance to the building. Architectural definition of the building entrance may include recession or protrusion of the entrance and/or an awning or a roof protrusion directly above the entrance. (6) First floor street-facing building wall transparency. A minimum of forty (40) percent of the area of a street-facing first floor building wall shall be clear, non-opaque window area, unless it is shown by the applicant that compliance with this standard is inherently in conflict with the type of use within the building and the proposal incorporates decorative or architectural features into the wall of the building as mitigation. Any such conflict shall be justified by the applicant, in writing, and accepted by the community development department. (7) Upper floor (above the first floor) street-facing building wall transparency. A minimum of thirty (30) percent of the area of a street-facing upper floor building wall shall be clear, non-opaque window area or incorporate architectural features that have similar visual effect in breaking up the appearance of the wall mass, unless it is shown by the applicant that compliance with this standard is inherently in conflict with the type of use within the building and the proposal incorporates decorative or architectural features into the wall of the building as mitigation. Any such conflict shall be justified by the applicant, in writing, and accepted by the community development department. (8) Outdoor lighting. Outdoor lighting for parking lots, walkways, usable open space, and exterior doorways shall be installed and designed to provide a safe and comfortable pedestrian environment. All such lighting shall be: a. A full cutoff design so that there is not light dispersion or direct glare above a 90-degree horizontal plane from the base of the fixture, or b. Contained within an opaque or semi-transparent globe or housing that does not produce glare from the light source (e.g., the light bulb). (9) Dumpster screening. Dumpsters shall be fully screened from view at ground level, unless located such that they are not visible from a street, public pedestrian path, and an adjoining property under separate ownership.
(Ord. No. 4725, § 5, 11-26-18; Ord. No. 4862, § 2, 1-23-23)
Ask a question about Lewiston law
Corpus searches the Lewiston sections it holds and shows the ones that match, with their citations. Free, no sign-in.
